AML / Dome Top Column Load Cell | Canister Load Cell | CCDDT


  • Capacities: 0-2te up to 0-1000te
  • Output: 1.5mV/V
  • Sealed to IP67 (IP68 submersible versions available)
  • Stainless Steel Construction
  • Optional Amplifier Output & Integral Connector
  • Can be Supplied with Loading Cap & Mounting Base
  • Long-Term Submersible Versions Available – Ideal for marine and offshore applications.
  • Lower Height Versions Available – To fit within your specific application.
  • Fast and Easy Installation – With our loading cap and mounting bases.
  • Immersion protected to 1 metre – for up to 30 mins.
  • Carry Handles Supplied for Units Over 200t
  • Get it Fast – Shorter delivery times on lower capacities.

Share it:

Dome Top Column Load Cell | Canister Load Cell | CCDDT

Robust, Accurate and Ideal for Permanent Outdoor Compression Measuring Applied Measurements CCDDT dome top column load cell is designed to make compression load measurements in general use applications or in permanent outdoor installations. Thanks to its stainless steel construction and IP67 dust-tight and immersion protection it is suitable for harsh environments. Further applications include hydraulic press calibration, pile force measurement, jack force measurement, centre of gravity measurement systems and structural proof testing. Verification standard versions are available which are suitable for use in laboratories, please see our 0.1% higher accuracy column load cell. Standard capacities for the Applied Measurements CCDDT dome top column load cell range from 2 tonnes up to 1000 tonnes, with higher capacity versions available on request. Capacities of 200te and above are supplied with welded carry handles as standard, included in the price. Optional welded carry handles are available for 50te and 100te only, if required. The dome top column load cell design can be readily modified to provide higher integrity where environmental conditions are particularly arduous such as in marine and offshore applications. IP68 fully submersible versions can be offered where such conditions prevail. It is also possible to manufacture low-height versions if space is at a premium. We can provide an optional loading cap and mounting base to ease installation and provide optimal performance from this canister load cell. Plus, carry handles are normally supplied on capacities over 200t to assist moving and installation. A high accuracy version of the CCDDT column load cell is available for use in verification and calibration systems as a reference standard.

Technical Specifications

Rated Capacity (RC) tonnes 0-2, 0-5, 0-10, 0-25, 0-50, 0-100, 0-200, 0-300, 0-500, 0-750, 0-1000
Operating Modes Compression Only
Sensitivity (RO) mV/V 1.5 nominal
Zero Balance/Offset ±%/Rated Output <1 typical
Non-Linearity ±%/Rated Load <0.25 typical
Hysteresis ±%/Rated Output <0.25 typical
Non-Repeatability ±%/Rated Load <0.05
Temperature Effect on Zero ±%/Rated Load / °C <0.01
Temperature Effect on Span ±%/Rated Load / °C <0.01
Bridge Resistance Ohms 700 (2 — 50te) | 1400 (100 — 1000te)
Insulation Resistance Megohms @ 500Vdc >500
Excitation Voltage Volts AC or DC 10 recommended (2 — 15 acceptable)
Operating Temperature Range °C -20 to +70
Compensated Temperature Range °C -10 to +50
Storage Temperature Range °C -20 to +70
Safe Overload % of Rated Load 150
Ultimate Overload % of Rated Load 300
Deflection @ Rated Capacity mm See dimensions table
IP Rating (Environmental Protection) IP67
Weight (exc cable) See dimensions table
Fatigue Life Full-Range Cycles 108 cycles typical (109 cycles on fatigue-rated version)
Cable Length as Standard metres 5
Cable Type 4-core screen, PUR sheath
Construction Material Stainless Steel
Resolution 1 part in 250,000 (with appropriate instrumentation)

Product Dimensions (mm)

CCDDT Outline
MODEL Capacity (t) H ØD R T S ØB Weight (kg) Resolution (t) Deflection at RC (mm,nominal)
CCDDT 2 41 36 29 M3 5 20 1 0.002 0.05
CCDDT 5 41 36 29 M3 5 20 1 0.005 0.05
CCDDT 10 75 59 75 M4 8 34 2.5 0.01 0.10
CCDDT 25 75 59 75 M4 8 34 2.5 0.02 0.10
CCDDT 50 103 88 158 M4 10 50 6.5 0.05 0.12
CCDDT 100 153 100 150 M5 12 70 11 0.1 0.18
CCDDT 200 180 125 165 M6 12 78 19 0.2 0.21
CCDDT 300 185 140 180 n/a n/a n/a 21 0.5 0.21
CCDDT 500 250 165 250 n/a n/a n/a 42 0.5 0.30
CCDDT 750 350 198 350 n/a n/a n/a 85 1.0 0.41
CCDDT 1000 400 276 400 n/a n/a n/a 220 1.0 0.46
Note: Dimensions may change for hazardous area versions.

Wiring Details

Wire Designation
Red +ve excitation
Blue -ve excitation
Green +ve signal
Yellow -ve signal
Screen To ground — not connected to load cell body

Ordering Codes & Options

Core Product Capacity (inc Engineering Units) Cable Length (m) Specials Code Example Result
CCDDT 2t 5 000 CCDDT-2t-005-000
CCDDT 5t 5 000 CCDDT-5t-005-000
CCDDT 10t 5 000 CCDDT-10t-005-000
CCDDT 25t 5 000 CCDDT-25t-005-000
CCDDT 50t 5 000 CCDDT-50t-005-000
CCDDT 100t 5 000 CCDDT-100t-005-000
CCDDT 200t 5 000 CCDDT-200t-005-000
CCDDT 300t 5 000 CCDDT-300t-005-000
CCDDT 500t 5 000 CCDDT-500t-005-000
CCDDT 1000t 5 000 CCDDT-1000t-005-000

Accessories

Spherical Load Cap Dimensions (Optional)

CCDDT spherical load cap
Capacity (t) H1 H2 ØD1 R
0-2 10 8 36 30
0-5 10 8 36 30
0-10 15 13 59 76
0-25 15 13 59 76
0-50 20 16 88 159
0-100 30 24 100 151
0-200 40 29 125 167
0-300 45 38 140 182
0-500 50 40 165 260
0-750 80 70 198 360
0-1000 80 70 276 410

Mounting Base Dimensions (Optional)

CCDDT mounting base
Capacity (t) ØB ØC H3 ØM ØP ØQ U
0-2 20 40 10 50 3.2 6 4
0-5 20 40 10 50 3.2 6 4
0-10 34 64 10 80 4.5 10 6
0-25 34 64 10 80 4.5 10 6
0-50 50 100 10 120 4.5 10 6
0-100 70 120 10 140 5.5 11 7