AML / Miniature Button Load Cell | CDFM3


  • Capacities: 0-100N up to 0-20kN
  • Output: 2mV/V nominal (1.5mV/V on 0-100N)
  • Environmental Protection: IP65
  • Accuracy: <±0.5%/RC
  • Integral Load Button
  • Very Compact – At Ø30mm x 12mm height it easily fits into the smallest of spaces.
  • Save on Installation Time – Ideal for retrofitting into existing designs.
  • Optimum Performance Guaranteed – From its integral load button
  • Let us do the hard work for you – The CDFM3 can be supplied with our wide range of instrumentation.

Share it:

Miniature Button Load Cell | CDFM3

Applied Measurements CDFM3 miniature button load cell is designed for compression measurement applications where there is little space available for transducer mounting. With capacities from 0-100N up to 0-20kN available in a load cell measuring just 30mm in diameter and 12mm in overall height, the CDFM3 is the second smallest button load cell that we offer. If you need load cell that is smaller still, the CDF miniature button load cell is available in capacities from 0-500N up to 0-2000N and measures 15mm diameter and 8mm in height. The CDFM3 miniature button load cell is ideal for retro-fitment into industrial machines and process systems for monitoring and control purposes, or for incorporation into new machine designs.

Technical Specifications

Rated Capacity (RC) N 0-100, 0-250, 0-500, 0-1000, 0-2000, 0-5000, 0-10k, 0-20k
Operating Modes Compression Only
Sensitivity (RO) mV/V 2 nominal (1.5 nominal on 100N)
Zero Balance/Offset ±%/Rated Output <0.5
Non-Linearity ±%/Rated Output (BFSL) <0.5
Hysteresis %/Rated Output <0.25
Repeatability %/Rated Output <0.2 typical
Temperature Effect on Zero ±%/Rated Output/ ˚C <0.030
Thermal Sensitivity F.R.O/Degrees C <0.005%
Input Resistance Ohms 375 typical
Output Resistance Ohms 350 typical
Insulation Resistance Megohms >2000
Excitation Voltage Volts AC or DC 10 recommended (2-15 acceptable)
Operating Temperature Range ˚C -20 to +70
Compensated Temperature Range ˚C +20 to +70
Storage Temperature Range ˚C -40 to +70
Safe Overload % of Rated Capacity 125
Ultimate Overload % of Rated Capacity 150
Deflection @ Rated Capacity 0.07 (100N) to 0.02 (20kN) typical (depending on capacity)
Fundamental Resonant Frequency* kHz 4 (100N) to 50 (20kN) *
IP Rating (Environmental Protection) IP65
Weight grams 50 (excluding cable)
Fatigue Life 108 cycles typical (109 cycles on fatigue-rated version)
Cable Length (as standard) metres 2
Electrical Connections Integral Screened Cable
Cable Type 4-core screened, PVC sheath via cable gland
Construction Material Stainless Steel, Nickel-Plated Brass, NBR, PVC
Resolution 1 part in 250,000 (with appropriate instrumentation)
*The resonant frequency is calculated with the body of the load cell attached to a large plate, ensuring that only the sensing element oscillates: This is vital to achieve the highest natural frequency and subsequent frequency response.

Product Dimensions (mm)

CDF Miniature Button Load Cell Outline Drawing

Wiring Details

Wire Designation
Red +ve excitation
Blue -ve excitation
Green +ve signal
Yellow -ve signal
Screen To ground – not connected to load cell body

VA25

Ordering Codes & Options

Core Product Capacity (inc Engineering Units) Cable Length (m) Specials Code Example Result
CDFM3 100N 002 000 CDFM3-100N-002-000
CDFM3 250N 002 000 CDFM3-250N-002-000
CDFM3 500N 002 000 CDFM3-500N-002-000
CDFM3 1000N 002 000 CDFM3-1000N-002-000
CDFM3 2000N 002 000 CDFM3-2000N-002-000
CDFM3 5000N 002 000 CDFM3-5000N-002-000
CDFM3 10kN 002 000 CDFM3-10kN-002-000
CDFM3 20kN 002 000 CDFM3-20kN-002-000