Models
FA05C
Features
Inputsingle Range:±3.6mV/V
Communication Interface:RS232/RS485
Communication protocols:Modbus-RTU
Dimensions
Specifications
Item | Unit | Specification |
---|---|---|
Channel Count | way | 1 way |
A/D Readability | bit | 24-bit Delta-Sigma (24 seats) |
A/D Conversion Speed | Hz | 1280Hz (Adjustable: 10Hz, 40Hz, 640Hz) |
Power Supply | VDC | DC 18–30V |
Input Signal Range | mV/V | ±3.6mV/V |
Excitation Voltage | VDC | 5VDC ±1%, 100mA |
Input Load | – | 1–8 pcs 350Ω sensors |
Input Sensitivity | mV/V | 0.4–6mV/V |
Output Linearity | – | 1/90000 |
Readability | % | <0.002 |
Comprehensive Accuracy | %F.S. | Better than 0.01 |
D/A Output Readability | bit | 16-bit |
D/A Output | – | ±10V, 4–20mA |
Digital Input | – | 1 channel IN |
Digital Output | – | 1 channel OUT (transistor) |
Temp. Effect on Output | ppm/°C | ≤10 |
Temp. Effect on Zero | μV/°C | ≤10 |
Power Consumption | W | ≤10 |
Communication Interface | – | RS-232 & RS-485 |
Communication Protocols | – | Modbus-RTU |
Baud Rate | bps | 4800, 9600 (default), 19200, 38400, 57600, 115200 |
Size | mm | 54 × 87.5 × 58.7 |
Operating Temperature Range | °C | -20 ~ 70 |
Material | – | ABS Engineering Plastics |
본 게시물은 케이센서스에 저작권이 있습니다. 무단으로 전제 및 도용 시 법적으로 처벌 될 수 있습니다. Copyright 2025. 케이센서스(KSENSORS) Co. All rights reserved. |