GALOCE / GPB147D / Digital parallel beam load cell


  • Aluminum alloy,surface anodized and anticorrosion;
  • Built-in digital module, digital signal output, RS485 or RS232;
  • Max platform size: 800×800mm;
  • Factory calibration, no calibration required Modify the acceleration of gravity and can be used in other places without calibration;
  • To change division value, after that, the corresponding weight can be output, no need for field calibration.
  • The sensor has only one zero-setting command and a weight read command are immediately accessed.
  • Mainly used in smart shelves, smart gravity cabinets, garbage recycling and others.

Share it:

GPB147D Digital parallel beam load cell

FEATURES

  • Aluminum alloy,surface anodized and anticorrosion;
  • Built-in digital module, digital signal output, RS485 or RS232; Max platform size: 800×800mm;
  • Factory calibration, no calibration required
  • Modify the acceleration of gravity and can be used in other places without calibration;
  • To change division value, after that, the corresponding weight can be output, no need for field calibration.
  • The sensor has only one zero-setting command and a weight read command are immediately accessed.
  • Mainly used in smart shelves, smart gravity cabinets, garbage recycling and others.

 

PARAMETER

Rated Load 200,300,500,600(kg)
 

Division Value

200~300kg,5g  

Weight data output rate

RS485:3ms
300~600kg,10g RS232:20ms
Detectability * Default 1  

Operating Temp.Range

RS485:-20~+70℃
Comprehensive Error 0.005%F.S RS232:-10~+70℃
Temp. Effect on Output 0.002%F.S/℃ Excitation,Recommended 5~12VDC
Temp. Effect on Zero 0.002%F.S/℃ Safe Overload 150%
Creep 0.018%F.S/30mins Ultimate Overload 200%
Output RS485 or RS232 Cable 4-Wire Shielded Cable
 

Baud rate

RS485:115200 Cable length φ4×3000mm
Rs232:19200 Ingress Protection IP65
A/D Sampling Rate 1200 times/sec  

Communication Protocol

RS485: MODBUS RTU and custom protocol
A/D Resolution 300000 RS232: Custom protocol

 

WIRING

RS232 RS485 Color Explain
+V +V Red 5~12VDC
GND GND Black 0V
RD A Green Connect external device TXD or A
TD B White Connect external device RXD or B