DB916A SERIES DOUBLE-ENDED SHEAR BEAM LOAD CELL
| Patameter | Units | Specifications | ||||||||||||
| Model No. | DB916A | |||||||||||||
| Rated capacity (Emax) | klb | 2.5 / 5 / 10 / 20 / 35 / 50 / 75 / 100 | ||||||||||||
| Accruacy class 1)2) | 0.03% | |||||||||||||
| Min. dead load | Ib | 0 | ||||||||||||
| Rated output | mV/V | 3.0 ± 0.003 | ||||||||||||
| Zero balance | % of Emax | ± 1 | ||||||||||||
| Repeatability error | % of AL 3) | < ± 0.010 | ||||||||||||
| Creep; 30 minute | % of AL | < ± 0.020 | ||||||||||||
| Min. dead load output return (DR); 30 min | % of AL | < ± 0.020 | ||||||||||||
| Temp. effect on | Min. dead load output | % of Emax/℃ | < ± 0.0014 | |||||||||||
| Rated output 2) | % of AL/℃ | < ± 0.0012 | ||||||||||||
| Temperature range | Compensated | ℃(°F) | -10 to +40 [+14 to +104] | |||||||||||
| Operating | -40 to +65 [-40 to +149] | |||||||||||||
| Safe storage | -40 to +80 [-40 to +176] | |||||||||||||
| Excitation voltage | Recommended | V AC/DC | 5 ~ 15 | |||||||||||
| Maximum | 20 | |||||||||||||
| Terminal resistance | Excitation | Ω | 766 ± 10 | |||||||||||
| Output | 700 ± 3 | |||||||||||||
| Insulation resistance @50VDC | MΩ | >5000 | ||||||||||||
| Breakdown voltage | V AC | >500 | ||||||||||||
| Seal type / IP rating | Hermetically welded / IP68 | |||||||||||||
| Load limit | Safe | % of Emax | 140 | |||||||||||
| Ultimate | 200 | |||||||||||||
| Material | Spring element | Alloy steel nickel plated | ||||||||||||
| Cable | Φ6; 4-wire; PVC | |||||||||||||
| Cable length | m | 2.5-5klb | 10-35klb | 50-75klb; 100klb | ||||||||||
| 6.0 | 12.0 | 16.0 | ||||||||||||
| Weight; approx | lb | 2.5-5klb | 10-35klb | 50-100K | ||||||||||
| 4.0 | 7.0 | 25;50 | ||||||||||||
| Fatigue life | cycles @Emax | >1,000,000 | ||||||||||||
| Deflection at Emax; approx | mm | <1.5 | ||||||||||||
| Barometric pressure effect on Zero Output | Vmin/kPa | <1.0 | ||||||||||||
| Notes: | ||||||||||||||
| 1) Error due to the combined effect of non-linearity and hysteresis | ||||||||||||||
| 2) The sum of errors due to Temperature Effect on Output comply with the requirements of OIML R60 and NIST HB44 | ||||||||||||||
| 3) AL = Applied Load | ||||||||||||||