Right / T701 / Bending Beam Load Cell


Widely used in Packaging scales, hopper scales, various industrial weighing systems, etc.
Material: Stainless steel
Features: Bellows type C3 accuracy


Share it:

T701 Bending Beam Load Cell

Dimension

T701 installation dimensions

Parameters

Specifications

Technique

Capacity

5,10,20,30,50,100,200,500 kg

Accuracy

C3

Zero Balance

2.0 ± 0.05 mV / V

Non-linearity

± 2% F.S.

Hysteresis Error

0.017% F.S.

Repetition

0.018% F.S.

Creep (30 min)

0.0166% F.S.

Temp. Effect on sensitivity (TKc)

0.008% F.S. / 10 ℃

Temp. Effect on zero balance (TKo)

0.0125 % F.S. / 10 ℃

Input resistance

390 ± 5 Ω

Output resistance

350 ± 5 Ω

Insulating Resistance

≥5000 MΩ / 100VDC

Excitation Voltage

5 ~ 15 V

Max. Excitation Voltage

20 V

Compensation Range

-10 ~ 40 ℃

Service Temperature Range

-30 ~ 70 ℃

Limit load (E L)

150% F.S.

Breaking load (E d)

300% F.S.

Cable size

φ5.4 × 1500 mm

Weight (G), approx.

0.5 kg

Material (Measuring element)

Stainless Steel

IP Class

IP68

Features and Applications

Suitable for various environments, IP 68

T701 fully welded stainless steel sensor can be used in humid environment and in water flushing environment to maintain its characteristics.

The low-section all-weld seal and high-precision design make it suitable for platform scales, packaging scales, belt scales and other places that require sealed sensors.

For locations with explosion-proof requirements, EEx ia certification is provided as an option.

Two feedback lines can feedback the sensor voltage changes. It can rely on voltage feedback to fully compensate for changes in resistance caused by changes in temperature or changes in sensor lead length.

 

Load direction

t701-2

Wiring Code

Wiring regulations