UTILCELL / DB520A SERIES DOUBLE-ENDED SHEAR BEAM LOAD CELL


Product description:

DB520A is a low-profile double ended shear beam load cells, which is designed for industrial vehicles and agricultural trailer high precision weighing system, Some high duty truck’s overload controlling is to ensure safe operation. The DB520A provides a very low-profile design which allows for a wide range of installation options for onboard vehicle weighing applications, Generally, the load cells are mounted between truck base chassis and upper frame, the lower profile, the more safer.

Main Features:

• Material: Alloy steel

• Rated Capacities: 15t

• IP Rating: IP68

• Suitable for onboard vehicle weighing system and other electronic weighing devices

• High precision, high reliability

Category: Double shear beam


Share it:

DB520A SERIES DOUBLE-ENDED SHEAR BEAM LOAD CELL

Patameter Units Specifications
Model No. DB520A
Rated capacity (Emax) t 15
Accruacy class 1)2) 0.1%
Min. dead load kg 0
Rated output mV/V 1.125 ± 0.005
Zero balance % of Emax ± 1
Repeatability error % of AL 3) < ± 0.02
Creep; 30 minute % of AL < ± 0.020
Min. dead load output return (DR); 30 min % of AL < ± 0.020
Temp. effect on Min. dead load output % of Emax/℃ < ± 0.002
Rated output 2) % of AL/℃ < ± 0.002
Temperature range Compensated ℃(°F) -10 to +40 [+14 to +104]
Operating -40 to +65 [-40 to +149]
Safe storage -40 to +80 [-40 to +176]
Excitation voltage Recommended V AC/DC 5 ~ 15
Maximum 15
Terminal resistance Excitation Ω 384 ± 10
Output 350 ± 3
Insulation resistance @50VDC >5000
Breakdown voltage V AC >500
Seal type / IP rating Hermetically welded / IP68
Load limit Safe % of Emax 200
Ultimate 300
Material Spring element Alloy steel nickel plated
Cable Φ6; 4-wire; PVC
Cable length m 10.0
Weight; approx kg 7.0
Fatigue life cycles @Emax >1,000,000
Deflection at Emax; approx mm <0.5
Barometric pressure effect on Zero Output Vmin/kPa <1.0
Notes:
1) Error due to the combined effect of non-linearity and hysteresis
2) The sum of errors due to Temperature Effect on Output comply with the requirements of OIML R60 and NIST HB44
3) AL = Applied Load