LC460 Column Type Load Cell 3000/5000 KN Multi-column Load Cell

Dimension: Unit:mm

Specifications:
케이센서스 스마트스토어

Dimension: Unit:mm

| Cap. / Size | D | D1 | H | H1 | H2 |
| 3000kN | 215 | 185 | 230 | 200 | 120 |
| 5000kN | 268 | 230 | 270 | 233 | 140 |
Specifications:
| Capacity: | 3000/5000 kN | ||
| Accuracy: | 0.1%FS | Insulation Resistance: | >2000MΩ |
| Sensitivity: | 2.0 m V/V | Temperature Effect On Sensitivity: | <0.1%FS/ 10℃ |
| Non-Linearity: | ≤0.1%FS | Temperature Effect On Zero Balance: | <0.1%FS/ 10℃ |
| Repeatability: | ≤0.05%FS | Reference Excitation Voltage: | 10V (DC) |
| Hysteresis: | ≤0.1%FS | Nominal Range Of Excitation Voltage: | 6~12V(DC) |
| Input Resistance: | 380Ω | Service Temperature: | -30~70℃ |
| Out Resistance: | 350Ω | Safe Load Limit: | 150%FS |
| Product name | LC460 Column Type Load Cell 3000/5000 KN Multi-column Load Cell |
| Brand | SAINTBOND |
| Market | All over the world |
| Features | High precision and stable performance |
| Advantage | 0EM/ODM |
| Sample Lead Time | 5~ 40Days |
| Sample price | The price is different according to product capacity |
| Custom Design | Welcome |
| Form of sale | Factory supply |
Product description:
Capacity :0~50kN
Aluminium Alloy
High stability
Can be installed in small spaces
Stable anti-interference signal
Widely used in automotive pressing, automatic assembly, 3C product testing, new energy product assembly, medical testing, machines Robot field, mold assembly and other industrial testing, motorizing equipment and testing field
| Model: | NF407 |
| Category: | Column Load Cells |
| Capacity: | 0.5,1,2,3,5,10,20,50,100kN |
| Rated Output: | 1.5±10%mV/V |
| Material: | Stainless steel |
| Protection Class: | ~ |
| Weight: | 0.8/2kg |
| Model: | NF411 |
| Category: | Column Load Cells |
| Capacity: | 5,10,20,50,100kN |
| Rated Output: | 1.0±10%mV/V |
| Material: | Stainless steel |
| Protection Class: | IP66 |
Column load cell with flange type body combined is an excellent performance weight measurement device for 5 ton/10 ton to 30 ton load measurement optional. It is made of high-strength alloy steel, which is robust and ensures stable operation in harsh environments.