Interface / MRT Static torque Sensor


Measuring range: 51k Nm

Accuracy: ±0.1%FS


Share it:

MRT Static torque Sensor

Technical parameters

Category Parameter MRT Series MRTP Series
Capacity Metric (Nm) 0.2, 2, 5, 10, 20 0.2
Imperial (lb-in) 1.77, 17.7, 44, 89, 177 1.77
Accuracy Class ( MAX ERROR )
Non-linearity — %FS ± 0.1 ± 0.1
Hysteresis — %FS ± 0.1 ± 0.1
Repeatability — %RO ± 0.05 ± 0.05
Creep (20 min) — % ± 0.10 ± 0.10
Temperature
Compensated Temp. Range — °C -10 to 45 -10 to 45
Operating Temp. Range — °C -55 to 90 -55 to 90
Temp. Effect on Zero — %RO/100°F ± 0.2 ± 0.2
Temp. Effect on Sensitivity — %RO/100°F ± 0.1 ± 0.1
Electrical
Sensitivity — mV/V 2.00 ± 0.30 2.00 ± 0.30
Excitation Voltage — VDC 10V DC (20 MAX) 10V DC (20 MAX)
Input Resistance — Ohm 700 + 100/7 700 + 100/7
Output Resistance — Ohm 700 ± 7 700 ± 7
Zero Balance (Output) — %RO ± 1.0 ± 1.0
Insulation Resistance — Megohm > 5000 > 5000
Mechanical
Safe Overload — %CAP ± 150 + 700
Ultimate Overload — %CAP ± 400
Side Load Capacity — N (lbf) 13 to 400 (3 to 90) 13 (3)
Safe Overhung Moment — %CAP 100 100
Safe Installation Torque — Nm (lb-in) 0.3 to 9 (2.7 to 80) 0.3 (2.7)
Deflection — radian 0.007 to 0.003 0.007
Cable Length — m 1.5 1.5

Dimensions

MRT

MRT