T326 Tension And Compression Bidirectional Load Cell
Dimension

Parameters
| Specifications |
Technique
|
| Capacity |
10,20,30,50,100,200,350,500,
1000,2000 kN
|
| Sensitivity |
1.5 ± 10 % mV / V
|
| Zero Balance |
0.05 mV / V
|
| Non-linearity |
0.1% F.S.
|
| Hysteresis Error |
0.1% F.S.
|
| Repetition |
0.05% F.S.
|
| Creep (30 min) |
0.05% F.S.
|
| Temp. Effect on sensitivity (TKc) |
0.05% F.S. / 10 ℃
|
| Temp. Effect on zero balance (TKo) |
0.05% F.S. / 10 ℃
|
| Input Resistance |
780 ± 20Ω / 385 ± 20Ω
|
| Output Resistance |
700 ± 10Ω / 350 ± 10Ω
|
| Insulating Resistance |
≥5000 MΩ / 100VDC
|
| Excitation Voltage |
5 ~ 15 V
|
| Max. Excitation Voltage |
20 V
|
| Compensation Range |
-10 ~ 40 ℃
|
| Service Temperature Range |
-20 ~70 ℃
|
| Limit load (EL) |
150% F.S.
|
| Breaking load (Ed) |
200% F.S.
|
| Material (Measuring element) |
Alloy Steel
|
| IP Class |
IP66
|
Features and Applications
Low height, small deformation and easy installation;
Tension and compression
Mainly used for pushing, pulling force gauge, hopper scale, various industrial weighing systems, etc .;
Automotive press assembly, automated assembly, 3C product testing, new energy product assembly,
Medical inspection, robotics, mold assembly.
Load Direction

Wiring Code