UTILCELL / SL5130 / Single Point Load Cell



Share it:

SL5130 Heavy Duty Shear Beam Load Cell

Technical Specifications

Specfications Technique
Maximum capacity (Emax) 0.5/1/2/5t;0.25/0.5/0.75/1/1.5/2/2.5/2.5KLE/3/4/5/5KSE/7.5/10/15/20klb
Accuracy class C3 C5 A5S B10M A5M
Approvals OIML R60 C3 OIML R60 C5
Maximum number of load cell intervals (nLC) 3000nmax 5000nmax III 5000 Single IIIL 10000 Multiple IIIL5000 Multiple
Ratio of minimum LC verification intervalY=Emax/Vmin Emax/10000Vmin Emax/18000Vmin Emax/15000Vmin Emax/10000Vmin Emax/15000Vmin
Combined error ≤±0.02%FS ≤±0.01%FS ≤±0.018%FS ≤±0.050%FS ≤±0.026%FS
Creep ≤±0.016%FS/30min ≤±0.012%FS/30min ≤±0.012%FS/30min ≤±0.040%FS/30min <+0.017%FS/30min
Temperature effect on sensitivity ≤±0.011%FS/10℃ ≤±0.013%FS/10℃
≤±0.007%FS/10C ≤±0.009%FS/10℃ ≤±0.040%FS/10C
Temperature effect on zero ≤±0.015%FS/10℃ ≤+0.014%FS/10C ≤±0.01%FS/10C ≤±0.020%FS/10C ≤+0.014%FS/10C
Output sensitivity(=FS) 3.0±0.008mV/V
Input resistance 350+3.5Ω
Output resistance 350±3.5Ω
Insulation resistance ≥5000MΩ(50VDC)
Zero balance ±1.0%FS
Compensated temperature -10~+40C
Operating temperature -35~+70°C
Excitation, recommended voltage 5~12V(DC)
Excitation maximum 18V(DC)
Safe overload 150%FS
Ultimate overload 300%FS
ATEX classification (optional) IIIG Ex ia II1C T4/II1D Ex iaD20 T73°C/II3G Ex nLIICT4
Wiring Red: Input+,Green: Output+, Transparent: Shield,Black: Input-,White: Output-
Cable diameter: p5mm; Shielded, 4 conductor cable;Standard cable length: 6m

Recommended selection model

xxkg

C3/C5/A5S/A5M/B10M

FA5130-xx-xxkg-6B

xxt

C3/C5/A5S/A5M/B10M

FA5130-xx-xxt-6B

xxlb

A5S/A5M/B10M

FA5130-xX-XX-6YB

xxklb

A5S/A5M/B10M

FA5130-xx-xxK-6YB

250lb

C3

FA5130-C3-250-6YB

15klb

C3

FA5130-C3-15K-6YB

20klb

C3

FA5130-C3-20K-6YB

200kg-500kg approved by OIML C5. 500kg-5.0t approved by OIML C3.

200KG-5.0t (500lb-10Klb) approved by NTEPA5S/A5M/B10M.

Product Dimensions

Installation size

SL5130-1.JPG

Dimension

Capacity

L

L1

L2

L3

d

H

W

D

H2

M

0.25klb,0.5klb,15.klb 0.75klb,1klb,2klb

130

(5.12)

15.7

(0.62)

25.4

(1.0)

76.2

(3.0)

13.46

(0.53)

28.4

(1.12)

30.7

(1.20)

13.4

(0.53)

14.22

(0.56)

M12–6H 1[2–20UNF–2B

0.5t,1t,2t,

2.5klb,3klb,4klb,5kSE

130

(5.12)

15.7

(0.62)

25.4

(1.0)

76.2

(3.0)

13.46

(0.53)

31.32

(1.23)

31.32

(1.23)

13.4

(0.53)

15.75

(0.62)

M12–6H 1[2–20UNF–2B

3t,5t,2.5kLE,5klb, 7.5klb,10klb,15klb

171

(6.73)

19

(0.75)

38.1

(1.5)

95.2

(3.75)

20.65

19.81

36.8

(1.45)

36.8

(1.45)

20.65

19.81

19.05

(0.75)

M20×2.5–6H 3[4–16UNF–2B

20klb

222.25

(8.75)

25.4

(1.0)

50.8

(2.0)

120.7

(4.75)

26.9

(1.06)

49.5

(1.95)

49.5

(1.95)

27.56

(1.08)

24.75

(0.97)

M24×2–6H 1–12UNF–2B

Accurate measurement with matching display

The output of the force measuring and weighing sensor itself is an MV signal, which needs to be amplified and convertedto display numerical values or output signals to the upper computer, PLC, etc.