{"id":330559,"date":"2026-02-11T12:04:07","date_gmt":"2026-02-11T03:04:07","guid":{"rendered":"https:\/\/ksensors.co.kr\/product\/sti-high-capacity-high-accuracy-tension-and-compression-canister-load-cell-series-cnr960\/"},"modified":"2026-02-11T12:04:07","modified_gmt":"2026-02-11T03:04:07","slug":"sti-high-capacity-high-accuracy-tension-and-compression-canister-load-cell-series-cnr960","status":"publish","type":"product","link":"https:\/\/ksensors.co.kr\/ru\/product\/sti-high-capacity-high-accuracy-tension-and-compression-canister-load-cell-series-cnr960\/","title":{"rendered":"STI \/ High Capacity-High Accuracy Tension and Compression Canister Load Cell-Series CNR960"},"content":{"rendered":"<h2>High Capacity-High Accuracy Tension and Compression Canister Load Cell-Series CNR960<\/h2>\n<p>These load cells are uniquely engineered to ensure a fast frequency response thanks to minimal deflection. They are constructed of nickel plated carbon steel that is electroless, and you can enjoy peace of mind that they are shock and vibration resistant.<\/p>\n<p>As standard, each unit comes shipped with a 10 point calibration (5 points each in both compression and tension) record traceable to NIST.<\/p>\n<p>&nbsp;<\/p>\n<p>The Series CNR960 tension \/ compression canister style load cells are designed specifically for high capacity and high accuracy test and measurement applications requiring long fatigue life combined with high resistance to the effects of extraneous bending and off-axis loading.<\/p>\n<p>The uniquely engineered CNR960 Series load cells have a minimum deflection resulting in fast frequency response. Constructed of electroless nickel plated carbon steel, all CNR960 load cells are manufactured to be shock and vibration resistant. Each unit is shipped with an 10 point calibration (5 points in both tension and compression) record traceable to NIST as standard.<\/p>\n<h4>Standard Features<\/h4>\n<ul>\n<li>Tension and Compression<\/li>\n<li>Load Ranges to 2 Million Pounds<\/li>\n<li>High Static Accuracy<\/li>\n<li>High Fatigue Life<\/li>\n<li>High Immunity to Off-Axis Loading<\/li>\n<li>Center Thread Mount or Circular Bolt Mount<\/li>\n<\/ul>\n<h4>Optional Features<\/h4>\n<ul>\n<li>Dual Bridge Configurations<\/li>\n<li>Customer Specified Electrical Termination<\/li>\n<li>Special Calibrations<\/li>\n<li>Metric Threads<\/li>\n<li>Expanded Temperature Compensation Ranges<\/li>\n<\/ul>\n<p>&nbsp;<\/p>\n<h4>Performance<\/h4>\n<p><strong>STANDARD Ranges<\/strong><\/p>\n<p>25K, 50K, 100K, 150K, 200K, 300K, 500K, 800K,<\/p>\n<p>1000K, 2000K lbf.<\/p>\n<p><strong>Static Accuracy<\/strong><\/p>\n<p>Linearity:\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0 \u00b1 0.2% FSO.<\/p>\n<p>Hysteresis:\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0 \u00b1 0.2% FSO. Repeatability:\u00a0\u00a0\u00a0\u00a0 \u00b1 0.05% FSO.<\/p>\n<p><strong>Temperature Effect on Zero<\/strong><\/p>\n<p>\u00b10.003% FSO\/\u00baF.<\/p>\n<p><strong>Temperature Effect on Span<\/strong><\/p>\n<p>\u00b1 0.003% Reading\/\u00baF.<\/p>\n<p><strong>Zero Balance<\/strong><\/p>\n<p>\u00b1 1% FSO at 70\u00baF.<\/p>\n<p><strong>Electrical Outputs<\/strong><\/p>\n<p>2 mV\/V<\/p>\n<h4>Environmental Characteristics<\/h4>\n<h3>Operating Temperature Range<\/h3>\n<p>-65\u00baF to + 250\u00baF.<\/p>\n<h3>Compensated Temperature Range<\/h3>\n<p>70\u00baF to 170\u00baF.<\/p>\n<p>Optional expanded ranges available<\/p>\n<p><img fetchpriority=\"high\" decoding=\"async\" class=\"aligncenter size-full wp-image-330554\" src=\"https:\/\/ksensors.co.kr\/wp-content\/uploads\/2026\/02\/CNR960-2.png\" alt=\"\" width=\"2431\" height=\"660\" \/><\/p>\n<table>\n<tbody>\n<tr>\n<td width=\"63\">CAPACITY (LBS)<\/td>\n<td width=\"34\">TYPE<\/td>\n<td width=\"33\">\u00d8OD<\/td>\n<td width=\"55\">Base OD<\/td>\n<td width=\"78\">Axial Thread<\/td>\n<td width=\"44\">Height<\/td>\n<td width=\"24\">X<\/td>\n<td width=\"120\">Mounting Holes<\/td>\n<td width=\"70\">N (Each End)<\/td>\n<td width=\"80\">Spanner Wrench Holes<\/td>\n<td width=\"22\">L<\/td>\n<td width=\"84\">Lifting Holes<\/td>\n<\/tr>\n<tr>\n<td width=\"63\">25K, 50K,<\/p>\n<p>100K, 150K<\/td>\n<td width=\"34\">A<\/td>\n<td width=\"33\">6<\/td>\n<td width=\"55\">5.5<\/td>\n<td width=\"78\">2-12 UN-2B,<\/p>\n<p>2.00 deep<\/td>\n<td width=\"44\">7.0<\/td>\n<td width=\"24\">6<\/td>\n<td width=\"120\">3\/4-10 UNC-2B, 1.25<\/p>\n<p>deep, \u00d83.50 B.C. Dia.<\/td>\n<td width=\"70\">3<\/td>\n<td width=\"80\">\u00d80.38,<\/p>\n<p>0.31 deep<\/td>\n<td width=\"22\">0<\/td>\n<td width=\"84\">N\/A<\/td>\n<\/tr>\n<tr>\n<td width=\"63\">150K, 200K,<\/p>\n<p>300K<\/td>\n<td width=\"34\">B<\/td>\n<td width=\"33\">7.5<\/td>\n<td width=\"55\">7.0<\/td>\n<td width=\"78\">3-12 UN-2B,<\/p>\n<p>3.00 deep<\/td>\n<td width=\"44\">10.0<\/td>\n<td width=\"24\">8<\/td>\n<td width=\"120\">1-8 UNC-2B, 1.50 deep, \u00d85.00 B.C. Dia.<\/td>\n<td width=\"70\">6<\/td>\n<td width=\"80\">\u00d80.41,<\/p>\n<p>0.38 deep<\/td>\n<td width=\"22\">0<\/td>\n<td width=\"84\">N\/A<\/td>\n<\/tr>\n<tr>\n<td width=\"63\">500K, 800K,<\/p>\n<p>1000K<\/td>\n<td width=\"34\">C<\/td>\n<td width=\"33\">12.8<\/td>\n<td width=\"55\">12.3<\/td>\n<td width=\"78\">5-8 UN-2B,<\/p>\n<p>3.50 deep<\/td>\n<td width=\"44\">12.5<\/td>\n<td width=\"24\">8<\/td>\n<td width=\"120\">1 3\/4 -12 UN-2B, 2.0 deep, \u00d89.50 B.C. Dia.<\/td>\n<td width=\"70\">4<\/td>\n<td width=\"80\">\u00d80.41,<\/p>\n<p>0.38 deep.<\/td>\n<td width=\"22\">2<\/td>\n<td width=\"84\">3\/8-16, UNC-2B,<\/p>\n<p>0.65 deep<\/td>\n<\/tr>\n<tr>\n<td width=\"63\">500K, 800K,<\/p>\n<p>1000K<\/td>\n<td width=\"34\">D<\/td>\n<td width=\"33\">12.8<\/td>\n<td width=\"55\">12.3<\/td>\n<td width=\"78\">5-8 UN-2B,<\/p>\n<p>5.30 deep<\/td>\n<td width=\"44\">16.0<\/td>\n<td width=\"24\">8<\/td>\n<td width=\"120\">1 3\/4 -12 UN-2B, 2.0 deep, \u00d89.50 B.C. Dia.<\/td>\n<td width=\"70\">4<\/td>\n<td width=\"80\">\u00d80.41,<\/p>\n<p>0.38 deep.<\/td>\n<td width=\"22\">2<\/td>\n<td width=\"84\">3\/8-16, UNC-2B,<\/p>\n<p>0.65 deep<\/td>\n<\/tr>\n<tr>\n<td width=\"63\">2000K<\/td>\n<td width=\"34\">E<\/td>\n<td width=\"33\">17.6<\/td>\n<td width=\"55\">17<\/td>\n<td width=\"78\">6-8 UN-2B,<\/p>\n<p>8.25 deep<\/td>\n<td width=\"44\">22.5<\/td>\n<td width=\"24\">12<\/td>\n<td width=\"120\">1 3\/4 -12 UN-2B, 3.5 deep, \u00d812.00 B.C. Dia.<\/td>\n<td width=\"70\">6<\/td>\n<td width=\"80\">\u00d80.41,<\/p>\n<p>0.38 deep<\/td>\n<td width=\"22\">2<\/td>\n<td width=\"84\">3\/4-10, UNC-2B,<\/p>\n<p>1.5 deep<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>Mechanical Characteristics<\/h2>\n<h4>Static Overload Without Damage<\/h4>\n<p>150% of nominal capacity.<\/p>\n<h4>Calibration<\/h4>\n<p>Standard calibration is 5 pts (0, 50%, 100%, 50%, 0) in both tension and compression.<\/p>\n<p><em>Important Note: Factory calibration based on <\/em><em>customer\u2019s use.Specify if load cell will be mounted using mounting bolt holes or axial threaded hole.<\/em><\/p>\n<h4>Material<\/h4>\n<p>Electroless nickel-plated carbon steel with painted carbon steel cover.<\/p>\n<h4>Fatigue Life<\/h4>\n<p>Greater than 100 million fully reversed cycles at FSO.<\/p>\n<p>&nbsp;<\/p>\n<h2>Electrical Characteristics<\/h2>\n<h4>Bridge Resistance<\/h4>\n<p>350 ohms (Types A, B). 700 ohms (Types C, D, E).<\/p>\n<h4>Excitation<\/h4>\n<p>10 Vdc or 10 Vac.<\/p>\n<h4>Maximum Excitation<\/h4>\n<p>&gt; 100 megohms at 50 Vdc at 70\u00b0F.<\/p>\n<h4>Insulation Resistance<\/h4>\n<p>Greater than 5000 megohms at 50 Vdc @ 70\u00baF.<\/p>\n<h4>Electrical Termination<\/h4>\n<p>MS-3102-14S-6P stainless steel electrical receptacle or equivalent.<\/p>\n<p><em>Optional electrical terminations, including <\/em><em>Integral<\/em> <em>cable,<\/em> <em>are<\/em> <em>available<\/em> <em>(consult<\/em> <em>factory).<\/em><\/p>\n<p>&nbsp;<\/p>\n<h2>Electrical Characteristics<\/h2>\n<h4>Standard Wiring Code<\/h4>\n<p>(Connector pin-outs)<\/p>\n<p>A\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0 +EXC<br \/>\nB\u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 +SIG<br \/>\nC\u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0-SIG<br \/>\nD\u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 -EXC<br \/>\nE\u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 N\/C<br \/>\nF\u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 N\/C<\/p>\n<p>&nbsp;<\/p>\n","protected":false},"excerpt":{"rendered":"<p>These canister style Series CNR960 load cells are suitable for tension \/ compression applications. They have been designed specifically for use in high accuracy and capacity applications, both for testing and measurement purposes. When you are looking for load cells that can resist the impacts of off-axis loading and extraneous bending, our Series CNR960 load cells are what you need.<\/p>\n","protected":false},"featured_media":330553,"template":"","meta":[],"product_brand":[3375],"product_cat":[2341],"product_tag":[1429,937],"class_list":{"0":"post-330559","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_brand-sti-ru","7":"product_cat-2341","8":"product_tag---ru-2","9":"product_tag--ru","11":"first","12":"instock","13":"taxable","14":"shipping-taxable","15":"product-type-simple"},"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v27.4 (Yoast SEO v27.4) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>STI \/ High Capacity-High Accuracy Tension and Compression Canister Load Cell-Series CNR960 - KSENSORS : \ucf00\uc774\uc13c\uc11c\uc2a4<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/ksensors.co.kr\/ru\/product\/sti-high-capacity-high-accuracy-tension-and-compression-canister-load-cell-series-cnr960\/\" \/>\n<meta property=\"og:locale\" content=\"ru_RU\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"STI \/ High Capacity-High Accuracy Tension and Compression Canister Load Cell-Series CNR960\" \/>\n<meta property=\"og:description\" content=\"These canister style Series CNR960 load cells are suitable for tension \/ compression applications. They have been designed specifically for use in high accuracy and capacity applications, both for testing and measurement purposes. When you are looking for load cells that can resist the impacts of off-axis loading and extraneous bending, our Series CNR960 load cells are what you need.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/ksensors.co.kr\/ru\/product\/sti-high-capacity-high-accuracy-tension-and-compression-canister-load-cell-series-cnr960\/\" \/>\n<meta property=\"og:site_name\" content=\"KSENSORS : \ucf00\uc774\uc13c\uc11c\uc2a4\" \/>\n<meta property=\"og:image\" content=\"https:\/\/ksensors.co.kr\/wp-content\/uploads\/2026\/02\/CNR960.png\" \/>\n\t<meta property=\"og:image:width\" content=\"350\" \/>\n\t<meta property=\"og:image:height\" content=\"315\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/png\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data1\" content=\"3 \u043c\u0438\u043d\u0443\u0442\u044b\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/ksensors.co.kr\\\/ru\\\/product\\\/sti-high-capacity-high-accuracy-tension-and-compression-canister-load-cell-series-cnr960\\\/\",\"url\":\"https:\\\/\\\/ksensors.co.kr\\\/ru\\\/product\\\/sti-high-capacity-high-accuracy-tension-and-compression-canister-load-cell-series-cnr960\\\/\",\"name\":\"STI \\\/ High Capacity-High Accuracy Tension and Compression Canister Load Cell-Series CNR960 - KSENSORS : \ucf00\uc774\uc13c\uc11c\uc2a4\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/ksensors.co.kr\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/ksensors.co.kr\\\/ru\\\/product\\\/sti-high-capacity-high-accuracy-tension-and-compression-canister-load-cell-series-cnr960\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/ksensors.co.kr\\\/ru\\\/product\\\/sti-high-capacity-high-accuracy-tension-and-compression-canister-load-cell-series-cnr960\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/ksensors.co.kr\\\/wp-content\\\/uploads\\\/2026\\\/02\\\/CNR960.png\",\"datePublished\":\"2026-02-11T03:04:07+00:00\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/ksensors.co.kr\\\/ru\\\/product\\\/sti-high-capacity-high-accuracy-tension-and-compression-canister-load-cell-series-cnr960\\\/#breadcrumb\"},\"inLanguage\":\"ru-RU\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/ksensors.co.kr\\\/ru\\\/product\\\/sti-high-capacity-high-accuracy-tension-and-compression-canister-load-cell-series-cnr960\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"ru-RU\",\"@id\":\"https:\\\/\\\/ksensors.co.kr\\\/ru\\\/product\\\/sti-high-capacity-high-accuracy-tension-and-compression-canister-load-cell-series-cnr960\\\/#primaryimage\",\"url\":\"https:\\\/\\\/ksensors.co.kr\\\/wp-content\\\/uploads\\\/2026\\\/02\\\/CNR960.png\",\"contentUrl\":\"https:\\\/\\\/ksensors.co.kr\\\/wp-content\\\/uploads\\\/2026\\\/02\\\/CNR960.png\",\"width\":350,\"height\":315},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/ksensors.co.kr\\\/ru\\\/product\\\/sti-high-capacity-high-accuracy-tension-and-compression-canister-load-cell-series-cnr960\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"\ud648\",\"item\":\"https:\\\/\\\/ksensors.co.kr\\\/ru\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"\u041c\u0430\u0433\u0430\u0437\u0438\u043d\",\"item\":\"https:\\\/\\\/ksensors.co.kr\\\/ru\\\/%d0%bc%d0%b0%d0%b3%d0%b0%d0%b7%d0%b8%d0%bd\\\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"STI \\\/ High Capacity-High Accuracy Tension and Compression Canister Load Cell-Series CNR960\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/ksensors.co.kr\\\/#website\",\"url\":\"https:\\\/\\\/ksensors.co.kr\\\/\",\"name\":\"KSENSORS : \ucf00\uc774\uc13c\uc11c\uc2a4\",\"description\":\"Load cell, torque center, displacement sensor, pressure sensor\",\"publisher\":{\"@id\":\"https:\\\/\\\/ksensors.co.kr\\\/#organization\"},\"alternateName\":\"KSENSORS\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/ksensors.co.kr\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"ru-RU\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/ksensors.co.kr\\\/#organization\",\"name\":\"\ucf00\uc774\uc13c\uc11c\uc2a4\",\"alternateName\":\"KSENSORS\",\"url\":\"https:\\\/\\\/ksensors.co.kr\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"ru-RU\",\"@id\":\"https:\\\/\\\/ksensors.co.kr\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/ksensors.co.kr\\\/wp-content\\\/uploads\\\/2025\\\/05\\\/EMBLEM.png\",\"contentUrl\":\"https:\\\/\\\/ksensors.co.kr\\\/wp-content\\\/uploads\\\/2025\\\/05\\\/EMBLEM.png\",\"width\":1711,\"height\":676,\"caption\":\"\ucf00\uc774\uc13c\uc11c\uc2a4\"},\"image\":{\"@id\":\"https:\\\/\\\/ksensors.co.kr\\\/#\\\/schema\\\/logo\\\/image\\\/\"}}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"STI \/ High Capacity-High Accuracy Tension and Compression Canister Load Cell-Series CNR960 - KSENSORS : \ucf00\uc774\uc13c\uc11c\uc2a4","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/ksensors.co.kr\/ru\/product\/sti-high-capacity-high-accuracy-tension-and-compression-canister-load-cell-series-cnr960\/","og_locale":"ru_RU","og_type":"article","og_title":"STI \/ High Capacity-High Accuracy Tension and Compression Canister Load Cell-Series CNR960","og_description":"These canister style Series CNR960 load cells are suitable for tension \/ compression applications. They have been designed specifically for use in high accuracy and capacity applications, both for testing and measurement purposes. When you are looking for load cells that can resist the impacts of off-axis loading and extraneous bending, our Series CNR960 load cells are what you need.","og_url":"https:\/\/ksensors.co.kr\/ru\/product\/sti-high-capacity-high-accuracy-tension-and-compression-canister-load-cell-series-cnr960\/","og_site_name":"KSENSORS : \ucf00\uc774\uc13c\uc11c\uc2a4","og_image":[{"width":350,"height":315,"url":"https:\/\/ksensors.co.kr\/wp-content\/uploads\/2026\/02\/CNR960.png","type":"image\/png"}],"twitter_card":"summary_large_image","twitter_misc":{"Est. reading time":"3 \u043c\u0438\u043d\u0443\u0442\u044b"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/ksensors.co.kr\/ru\/product\/sti-high-capacity-high-accuracy-tension-and-compression-canister-load-cell-series-cnr960\/","url":"https:\/\/ksensors.co.kr\/ru\/product\/sti-high-capacity-high-accuracy-tension-and-compression-canister-load-cell-series-cnr960\/","name":"STI \/ High Capacity-High Accuracy Tension and Compression Canister Load Cell-Series CNR960 - KSENSORS : \ucf00\uc774\uc13c\uc11c\uc2a4","isPartOf":{"@id":"https:\/\/ksensors.co.kr\/#website"},"primaryImageOfPage":{"@id":"https:\/\/ksensors.co.kr\/ru\/product\/sti-high-capacity-high-accuracy-tension-and-compression-canister-load-cell-series-cnr960\/#primaryimage"},"image":{"@id":"https:\/\/ksensors.co.kr\/ru\/product\/sti-high-capacity-high-accuracy-tension-and-compression-canister-load-cell-series-cnr960\/#primaryimage"},"thumbnailUrl":"https:\/\/ksensors.co.kr\/wp-content\/uploads\/2026\/02\/CNR960.png","datePublished":"2026-02-11T03:04:07+00:00","breadcrumb":{"@id":"https:\/\/ksensors.co.kr\/ru\/product\/sti-high-capacity-high-accuracy-tension-and-compression-canister-load-cell-series-cnr960\/#breadcrumb"},"inLanguage":"ru-RU","potentialAction":[{"@type":"ReadAction","target":["https:\/\/ksensors.co.kr\/ru\/product\/sti-high-capacity-high-accuracy-tension-and-compression-canister-load-cell-series-cnr960\/"]}]},{"@type":"ImageObject","inLanguage":"ru-RU","@id":"https:\/\/ksensors.co.kr\/ru\/product\/sti-high-capacity-high-accuracy-tension-and-compression-canister-load-cell-series-cnr960\/#primaryimage","url":"https:\/\/ksensors.co.kr\/wp-content\/uploads\/2026\/02\/CNR960.png","contentUrl":"https:\/\/ksensors.co.kr\/wp-content\/uploads\/2026\/02\/CNR960.png","width":350,"height":315},{"@type":"BreadcrumbList","@id":"https:\/\/ksensors.co.kr\/ru\/product\/sti-high-capacity-high-accuracy-tension-and-compression-canister-load-cell-series-cnr960\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"\ud648","item":"https:\/\/ksensors.co.kr\/ru\/"},{"@type":"ListItem","position":2,"name":"\u041c\u0430\u0433\u0430\u0437\u0438\u043d","item":"https:\/\/ksensors.co.kr\/ru\/%d0%bc%d0%b0%d0%b3%d0%b0%d0%b7%d0%b8%d0%bd\/"},{"@type":"ListItem","position":3,"name":"STI \/ High Capacity-High Accuracy Tension and Compression Canister Load Cell-Series CNR960"}]},{"@type":"WebSite","@id":"https:\/\/ksensors.co.kr\/#website","url":"https:\/\/ksensors.co.kr\/","name":"KSENSORS : \ucf00\uc774\uc13c\uc11c\uc2a4","description":"Load cell, torque center, displacement sensor, pressure sensor","publisher":{"@id":"https:\/\/ksensors.co.kr\/#organization"},"alternateName":"KSENSORS","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/ksensors.co.kr\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"ru-RU"},{"@type":"Organization","@id":"https:\/\/ksensors.co.kr\/#organization","name":"\ucf00\uc774\uc13c\uc11c\uc2a4","alternateName":"KSENSORS","url":"https:\/\/ksensors.co.kr\/","logo":{"@type":"ImageObject","inLanguage":"ru-RU","@id":"https:\/\/ksensors.co.kr\/#\/schema\/logo\/image\/","url":"https:\/\/ksensors.co.kr\/wp-content\/uploads\/2025\/05\/EMBLEM.png","contentUrl":"https:\/\/ksensors.co.kr\/wp-content\/uploads\/2025\/05\/EMBLEM.png","width":1711,"height":676,"caption":"\ucf00\uc774\uc13c\uc11c\uc2a4"},"image":{"@id":"https:\/\/ksensors.co.kr\/#\/schema\/logo\/image\/"}}]}},"_links":{"self":[{"href":"https:\/\/ksensors.co.kr\/ru\/wp-json\/wp\/v2\/product\/330559","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/ksensors.co.kr\/ru\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/ksensors.co.kr\/ru\/wp-json\/wp\/v2\/types\/product"}],"version-history":[{"count":0,"href":"https:\/\/ksensors.co.kr\/ru\/wp-json\/wp\/v2\/product\/330559\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/ksensors.co.kr\/ru\/wp-json\/wp\/v2\/media\/330553"}],"wp:attachment":[{"href":"https:\/\/ksensors.co.kr\/ru\/wp-json\/wp\/v2\/media?parent=330559"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/ksensors.co.kr\/ru\/wp-json\/wp\/v2\/product_brand?post=330559"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/ksensors.co.kr\/ru\/wp-json\/wp\/v2\/product_cat?post=330559"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/ksensors.co.kr\/ru\/wp-json\/wp\/v2\/product_tag?post=330559"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}