{"id":307690,"date":"2026-01-05T13:45:54","date_gmt":"2026-01-05T04:45:54","guid":{"rendered":"https:\/\/ksensors.co.kr\/product\/zemic-l3v-load-cells-zemic-load-cell-weight-sensor\/"},"modified":"2026-01-05T13:50:08","modified_gmt":"2026-01-05T04:50:08","slug":"zemic-l3v-load-cells-zemic-load-cell-weight-sensor","status":"publish","type":"product","link":"https:\/\/ksensors.co.kr\/ru\/product\/zemic-l3v-load-cells-zemic-load-cell-weight-sensor\/","title":{"rendered":"Zemic \/ L3V Load Cells Zemic Load Cell Weight Sensor"},"content":{"rendered":"<h1 class=\"this-description-name\">L3V Load Cells Zemic Load Cell Weight Sensor<\/h1>\n<p><strong><a>Product Description<\/a><\/strong><\/p>\n<div class=\"detial-cont-tabscont\">\n<div class=\"fix prodDesc\">\n<div class=\"prodDetail-editor-container \">\n<p><img decoding=\"async\" class=\" lazyloaded\" title=\"\u56fe\u72471\" src=\"https:\/\/ksensors.co.kr\/wp-content\/uploads\/2026\/01\/144_tupian1.png\" alt=\"\u56fe\u72471\" data-original=\"\/\/ilrorwxhklojlp5p.ldycdn.com\/cloud\/llBpoKmlliSRojmknmniip\/tupian1.png\" \/><\/p>\n<p><strong>Short Description:<\/strong><\/p>\n<p>\u25ceSpraying plastic surface aluminum alloy IP66 &#171;S&#187; type load cell\uff1b<\/p>\n<p>\u25ceTension and compression applications\uff1b<\/p>\n<p>\u25ce Suitable for textile machinery measuring and other\u00a0electronic measuring systems\uff1b<\/p>\n<p><strong>Available models\uff1a<\/strong><\/p>\n<div class=\"sliderTable mt10 mb10 sliderTable-index0 change-to-org\">\n<div class=\"inner\">\n<table width=\"628\">\n<tbody>\n<tr class=\"firstRow\">\n<td valign=\"center\" width=\"208\">Capacity<\/td>\n<td valign=\"center\" width=\"159\">Accuracy<\/td>\n<td valign=\"center\" width=\"261\">Full article description<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\" width=\"208\">200kg-700kg<\/td>\n<td valign=\"center\" width=\"159\">C2<\/td>\n<td valign=\"center\" width=\"261\">L3V-C2-xxkg-2.6B<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<p><strong>Specification\uff1a<\/strong><\/p>\n<div class=\"sliderTable mt10 mb10 sliderTable-index1 change-to-org\">\n<div class=\"inner\">\n<table width=\"628\">\n<tbody>\n<tr class=\"firstRow\">\n<td valign=\"center\" width=\"258\">Maximum capacity ( Emax)<\/td>\n<td valign=\"center\" width=\"121\">kg<\/td>\n<td valign=\"center\" width=\"249\">200\/250\/500\/700<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\" width=\"258\">Output sensitivity(= FS)<\/td>\n<td valign=\"center\" width=\"121\">mV\/V<\/td>\n<td valign=\"center\" width=\"249\">2.3\u00b10.2<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\" width=\"258\">Accuracy class<\/td>\n<td valign=\"center\" width=\"121\"><\/td>\n<td valign=\"center\" width=\"249\">C2<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\" width=\"258\">Combined error<\/td>\n<td valign=\"center\" width=\"121\">%FS<\/td>\n<td valign=\"center\" width=\"249\">\u00b10.03<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\" width=\"258\">Creep<\/td>\n<td valign=\"center\" width=\"121\">%FS\/30min<\/td>\n<td valign=\"center\" width=\"249\">\u00b10.024<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\" width=\"258\">Temperature effect on sensitivity<\/td>\n<td valign=\"center\" width=\"121\">%FS\/10\u2103<\/td>\n<td valign=\"center\" width=\"249\">\u00b10.03<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\" width=\"258\">Temperature effect on zero<\/td>\n<td valign=\"center\" width=\"121\">%FS\/10\u2103<\/td>\n<td valign=\"center\" width=\"249\">\u00b10.5<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\" width=\"258\">Zero balance<\/td>\n<td valign=\"center\" width=\"121\">%FS<\/td>\n<td valign=\"center\" width=\"249\">\u00b11.5<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\" width=\"258\">Compensated temperature<\/td>\n<td valign=\"center\" width=\"121\">\u2103<\/td>\n<td valign=\"center\" width=\"249\">(210~+40<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\" width=\"258\">Operating temperature<\/td>\n<td valign=\"center\" width=\"121\">\u2103<\/td>\n<td valign=\"center\" width=\"249\">-35~+65<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\" width=\"258\">Storage temperature<\/td>\n<td valign=\"center\" width=\"121\">\u2103<\/td>\n<td valign=\"center\" width=\"249\">-40~+70<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\" width=\"258\">Input resistance<\/td>\n<td valign=\"center\" width=\"121\">\u03a9<\/td>\n<td valign=\"center\" width=\"249\">410\u00b130<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\" width=\"258\">Output resistance<\/td>\n<td valign=\"center\" width=\"121\">\u03a9<\/td>\n<td valign=\"center\" width=\"249\">350\u00b13<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\" width=\"258\">Insulation resistance<\/td>\n<td valign=\"center\" width=\"121\">M\u03a9<\/td>\n<td valign=\"center\" width=\"249\">\u2265 5000(50VDC)<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\" width=\"258\">Excitation, recommended voltage<\/td>\n<td valign=\"center\" width=\"121\">V<\/td>\n<td valign=\"center\" width=\"249\">5~12(DC)<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\" width=\"258\">Excitation maximum<\/td>\n<td valign=\"center\" width=\"121\">V<\/td>\n<td valign=\"center\" width=\"249\">18(DC)<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\" width=\"258\">Safe overload<\/td>\n<td valign=\"center\" width=\"121\">of Emax<\/td>\n<td valign=\"center\" width=\"249\">120<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\" width=\"258\">UItimate overload<\/td>\n<td valign=\"center\" width=\"121\">of Emax<\/td>\n<td valign=\"center\" width=\"249\">150<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\" width=\"258\">lngress protection (according to EN 60529)<\/td>\n<td valign=\"center\" width=\"121\"><\/td>\n<td valign=\"center\" width=\"249\">IP66<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\" width=\"258\">Cable specification<\/td>\n<td valign=\"center\" width=\"121\">mm<\/td>\n<td valign=\"center\" width=\"249\">\u03d55.0<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\" width=\"258\">Cable length<\/td>\n<td valign=\"center\" width=\"121\">m<\/td>\n<td valign=\"center\" width=\"249\">2.6<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\" width=\"258\">Recommended torque on fixation<\/td>\n<td valign=\"center\" width=\"121\">N.m<\/td>\n<td valign=\"center\" width=\"249\">100<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<p><strong>\u00a0<\/strong><\/p>\n<p><strong>Dimensions in mm\uff1a<\/strong><\/p>\n<p><img decoding=\"async\" class=\" lazyloaded\" title=\"\u56fe\u72472\" src=\"https:\/\/ksensors.co.kr\/wp-content\/uploads\/2026\/01\/139_tupian2.png\" alt=\"\u56fe\u72472\" data-original=\"\/\/ilrorwxhklojlp5p.ldycdn.com\/cloud\/lkBpoKmlliSRojmknmliip\/tupian2.png\" \/><\/p>\n<\/div>\n<\/div>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<p>L3V Load Cells Zemic Load Cell Weight Sensor Product Description Short Description: \u25ceSpraying plastic surface aluminum alloy IP66 &#171;S&#187; type load cell\uff1b \u25ceTension and compression applications\uff1b \u25ce Suitable for textile machinery measuring and other\u00a0electronic measuring systems\uff1b Available models\uff1a Capacity Accuracy Full article description 200kg-700kg C2 L3V-C2-xxkg-2.6B Specification\uff1a Maximum capacity ( Emax) kg 200\/250\/500\/700 Output sensitivity(= [&hellip;]<\/p>\n","protected":false},"featured_media":307681,"template":"","meta":[],"product_brand":[2432],"product_cat":[414],"product_tag":[507],"class_list":{"0":"post-307690","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_brand-zemic-ru","7":"product_cat-s--","8":"product_tag-s--","10":"first","11":"instock","12":"taxable","13":"shipping-taxable","14":"product-type-simple"},"aioseo_notices":[],"_links":{"self":[{"href":"https:\/\/ksensors.co.kr\/ru\/wp-json\/wp\/v2\/product\/307690","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/ksensors.co.kr\/ru\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/ksensors.co.kr\/ru\/wp-json\/wp\/v2\/types\/product"}],"version-history":[{"count":0,"href":"https:\/\/ksensors.co.kr\/ru\/wp-json\/wp\/v2\/product\/307690\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/ksensors.co.kr\/ru\/wp-json\/wp\/v2\/media\/307681"}],"wp:attachment":[{"href":"https:\/\/ksensors.co.kr\/ru\/wp-json\/wp\/v2\/media?parent=307690"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/ksensors.co.kr\/ru\/wp-json\/wp\/v2\/product_brand?post=307690"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/ksensors.co.kr\/ru\/wp-json\/wp\/v2\/product_cat?post=307690"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/ksensors.co.kr\/ru\/wp-json\/wp\/v2\/product_tag?post=307690"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}