{"id":294512,"date":"2025-12-19T14:42:30","date_gmt":"2025-12-19T05:42:30","guid":{"rendered":"https:\/\/ksensors.co.kr\/product\/utilcell-lp510s-load-pin\/"},"modified":"2025-12-19T14:42:30","modified_gmt":"2025-12-19T05:42:30","slug":"utilcell-lp510s-load-pin","status":"publish","type":"product","link":"https:\/\/ksensors.co.kr\/ru\/product\/utilcell-lp510s-load-pin\/","title":{"rendered":"UTILCELL \/  LP510S LOAD PIN"},"content":{"rendered":"<h1>LP510S LOAD PIN<\/h1>\n<div class=\"product-info-content\">\n<table class=\"table1\">\n<tbody>\n<tr class=\"firstRow\">\n<td colspan=\"2\" rowspan=\"1\">Parameter<\/td>\n<td>Units<\/td>\n<td>Specification<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" rowspan=\"1\">Model No.<\/td>\n<td colspan=\"1\" rowspan=\"1\"><\/td>\n<td colspan=\"1\" rowspan=\"1\">LP510S<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" rowspan=\"1\">Rated capacity (Emax)<\/td>\n<td colspan=\"1\" rowspan=\"1\">kN<\/td>\n<td colspan=\"1\" rowspan=\"1\">90kN<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" rowspan=\"1\">Min. dead load<\/td>\n<td colspan=\"1\" rowspan=\"1\">kg<\/td>\n<td colspan=\"1\" rowspan=\"1\">0<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" rowspan=\"1\">Rated output<\/td>\n<td colspan=\"1\" rowspan=\"1\">mV\/V<\/td>\n<td colspan=\"1\" rowspan=\"1\">1.0 \u00b1 0.5%<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" rowspan=\"1\">Zero balance<\/td>\n<td colspan=\"1\" rowspan=\"1\">% of Emax<\/td>\n<td colspan=\"1\" rowspan=\"1\">\u00b1 1<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" rowspan=\"1\">Combined error 1)2)<\/td>\n<td colspan=\"1\" rowspan=\"1\">% of Emax<\/td>\n<td colspan=\"1\" rowspan=\"1\">\uff1c \u00b1 0.5<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" rowspan=\"1\">Repeatability error<\/td>\n<td colspan=\"1\" rowspan=\"1\">% of AL 3)<\/td>\n<td colspan=\"1\" rowspan=\"1\">\uff1c \u00b1 0.3<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" rowspan=\"1\">Creep; 30 minute<\/td>\n<td colspan=\"1\" rowspan=\"1\">% of AL<\/td>\n<td colspan=\"1\" rowspan=\"1\">\uff1c \u00b1 0.1<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" rowspan=\"1\">Min. dead load output return (DR); 30 min<\/td>\n<td colspan=\"1\" rowspan=\"1\">% of AL<\/td>\n<td colspan=\"1\" rowspan=\"1\">\uff1c \u00b1 0.1<\/td>\n<\/tr>\n<tr>\n<td colspan=\"1\" rowspan=\"2\">Temp. effect on<\/td>\n<td>Min. dead load output<\/td>\n<td>% of Emax\/\u2103<\/td>\n<td>\uff1c \u00b1 0.005<\/td>\n<\/tr>\n<tr>\n<td>Rated output 2)<\/td>\n<td>% of AL\/\u2103<\/td>\n<td>\uff1c \u00b1 0.01<\/td>\n<\/tr>\n<tr>\n<td colspan=\"1\" rowspan=\"3\">Temperature range<\/td>\n<td>Compensated<\/td>\n<td colspan=\"1\" rowspan=\"3\">\u2103(\u00b0F)<\/td>\n<td>-10 to +40 [+14 to +104]<\/td>\n<\/tr>\n<tr>\n<td>Operating<\/td>\n<td>-30 to +65 [-22 to +149]<\/td>\n<\/tr>\n<tr>\n<td>Safe storage<\/td>\n<td>-40 to +80 [-40 to +176]<\/td>\n<\/tr>\n<tr>\n<td colspan=\"1\" rowspan=\"2\">Excitation voltage<\/td>\n<td>Recommended<\/td>\n<td colspan=\"1\" rowspan=\"2\">V AC\/DC<\/td>\n<td>5 ~ 15<\/td>\n<\/tr>\n<tr>\n<td>Maximum<\/td>\n<td>20<\/td>\n<\/tr>\n<tr>\n<td colspan=\"1\" rowspan=\"2\">Terminal resistance<\/td>\n<td>Excitation<\/td>\n<td colspan=\"1\" rowspan=\"2\">\u03a9<\/td>\n<td>382 \u00b1 10<\/td>\n<\/tr>\n<tr>\n<td>Output<\/td>\n<td>350 \u00b1 3<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" rowspan=\"1\">Insulation resistance @50VDC<\/td>\n<td colspan=\"1\" rowspan=\"1\">M\u03a9<\/td>\n<td colspan=\"1\" rowspan=\"1\">\uff1e5000<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" rowspan=\"1\">Breakdown voltage<\/td>\n<td colspan=\"1\" rowspan=\"1\">V AC<\/td>\n<td colspan=\"1\" rowspan=\"1\">\uff1e500<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" rowspan=\"1\">Seal type \/ IP rating<\/td>\n<td colspan=\"1\" rowspan=\"1\"><\/td>\n<td colspan=\"1\" rowspan=\"1\">Hermetically welded \/ IP68<\/td>\n<\/tr>\n<tr>\n<td colspan=\"1\" rowspan=\"2\">Load limit<\/td>\n<td colspan=\"1\" rowspan=\"1\">Safe<\/td>\n<td colspan=\"1\" rowspan=\"2\">% of Emax<\/td>\n<td colspan=\"1\" rowspan=\"1\">300<\/td>\n<\/tr>\n<tr>\n<td colspan=\"1\" rowspan=\"1\">Ultimate<\/td>\n<td colspan=\"1\" rowspan=\"1\">500<\/td>\n<\/tr>\n<tr>\n<td colspan=\"1\" rowspan=\"2\">Material<\/td>\n<td colspan=\"1\" rowspan=\"1\">Spring element<\/td>\n<td colspan=\"1\" rowspan=\"1\"><\/td>\n<td colspan=\"1\" rowspan=\"1\">Stainless steel<\/td>\n<\/tr>\n<tr>\n<td colspan=\"1\" rowspan=\"1\">Cable<\/td>\n<td colspan=\"1\" rowspan=\"1\"><\/td>\n<td colspan=\"1\" rowspan=\"1\">\u03a66; 4-wire; PVC<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" rowspan=\"1\">Cable length<\/td>\n<td colspan=\"1\" rowspan=\"1\">m<\/td>\n<td colspan=\"1\" rowspan=\"1\">3.0<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" rowspan=\"1\">Weight; approx<\/td>\n<td colspan=\"1\" rowspan=\"1\">kg<\/td>\n<td colspan=\"1\" rowspan=\"1\">1.6<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" rowspan=\"1\">Fatigue life<\/td>\n<td colspan=\"1\" rowspan=\"1\">cycles @Emax<\/td>\n<td colspan=\"1\" rowspan=\"1\">\uff1e1,000,000<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" rowspan=\"1\">Deflection at Emax; approx<\/td>\n<td colspan=\"1\" rowspan=\"1\">mm<\/td>\n<td colspan=\"1\" rowspan=\"1\">\uff1c0.5<\/td>\n<\/tr>\n<tr>\n<td colspan=\"4\" rowspan=\"1\">Notes:<\/td>\n<\/tr>\n<tr>\n<td colspan=\"4\" rowspan=\"1\">1) Error due to the combined effect of non-linearity and hysteresis<\/td>\n<\/tr>\n<tr>\n<td colspan=\"4\" rowspan=\"1\">2) The sum of errors due to Temperature Effect on Output comply with the requirements of OIML R60 and NIST HB44<\/td>\n<\/tr>\n<tr>\n<td colspan=\"4\" rowspan=\"1\">3) AL = Applied Load<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><img decoding=\"async\" src=\"https:\/\/www.weighingcell.com\/static\/upload\/image\/20240902\/1725244163324229.jpg\" \/><\/p>\n<\/div>\n<div class=\"pro-back text-right\"><\/div>\n<div class=\"row pre-next mt-5 mb-5\"><\/div>\n","protected":false},"excerpt":{"rendered":"<div class=\"scrollbox\">\n<div class=\"scrollbox\">\n<div class=\"scrollbox\">\n<div class=\"scrollbox\">\n<p><strong>Product description:<\/strong><\/p>\n<p>LP510S is special double ended shear beam load cell, its sharp is pin, it is with throughout-hole to accommodate strain gauge, instead of typical side 4pcs cavities, which improve sealing performance significantly, not easy damaged in harsh environment.<\/p>\n<p><strong>Main Features:<\/strong><\/p>\n<p>\u2022 Material: Stainless steel<\/p>\n<p>\u2022 Rated Capacities: 25KN~90KN<\/p>\n<p>\u2022 Through-hole to accommodate strain gauge<\/p>\n<p>\u2022 IP Rating: IP69K<\/p>\n<p>\u2022 Suitable for force measurement device and safety controlling against overload<\/p>\n<p>\u2022 Excellent sealing performance<\/p>\n<\/div>\n<p>Category: Others<\/p>\n<\/div>\n<\/div>\n<\/div>\n","protected":false},"featured_media":294509,"template":"","meta":[],"product_brand":[2448],"product_cat":[1840,415],"product_tag":[1140],"class_list":{"0":"post-294512","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_brand-utilcell-ru","7":"product_cat-1840","8":"product_cat-s---","9":"product_tag---ru","11":"first","12":"instock","13":"taxable","14":"shipping-taxable","15":"product-type-simple"},"aioseo_notices":[],"_links":{"self":[{"href":"https:\/\/ksensors.co.kr\/ru\/wp-json\/wp\/v2\/product\/294512","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/ksensors.co.kr\/ru\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/ksensors.co.kr\/ru\/wp-json\/wp\/v2\/types\/product"}],"version-history":[{"count":0,"href":"https:\/\/ksensors.co.kr\/ru\/wp-json\/wp\/v2\/product\/294512\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/ksensors.co.kr\/ru\/wp-json\/wp\/v2\/media\/294509"}],"wp:attachment":[{"href":"https:\/\/ksensors.co.kr\/ru\/wp-json\/wp\/v2\/media?parent=294512"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/ksensors.co.kr\/ru\/wp-json\/wp\/v2\/product_brand?post=294512"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/ksensors.co.kr\/ru\/wp-json\/wp\/v2\/product_cat?post=294512"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/ksensors.co.kr\/ru\/wp-json\/wp\/v2\/product_tag?post=294512"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}