{"id":294185,"date":"2025-12-19T11:46:00","date_gmt":"2025-12-19T02:46:00","guid":{"rendered":"https:\/\/ksensors.co.kr\/product\/utilcell-b560s-b760s-single-ended-beam-load-cell\/"},"modified":"2025-12-19T11:46:00","modified_gmt":"2025-12-19T02:46:00","slug":"utilcell-b560s-b760s-single-ended-beam-load-cell","status":"publish","type":"product","link":"https:\/\/ksensors.co.kr\/ru\/product\/utilcell-b560s-b760s-single-ended-beam-load-cell\/","title":{"rendered":"UTILCELL \/ B560S\/B760S SINGLE-ENDED BEAM LOAD CELL"},"content":{"rendered":"<h1>B560S\/B760S SINGLE-ENDED BEAM LOAD CELL<\/h1>\n<table class=\"table1\">\n<tbody>\n<tr class=\"firstRow\">\n<td colspan=\"2\" rowspan=\"1\">Patameter<\/td>\n<td>Units<\/td>\n<td colspan=\"4\" rowspan=\"1\">Specifications<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" rowspan=\"1\">Model No.<\/td>\n<td><\/td>\n<td colspan=\"4\" rowspan=\"1\">B560S\/B760S<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" rowspan=\"2\">Rated capacity (Emax)<\/td>\n<td>kN<\/td>\n<td>5 \/ 10 \/20<\/td>\n<td colspan=\"2\" rowspan=\"1\">50<\/td>\n<td>100<\/td>\n<\/tr>\n<tr>\n<td colspan=\"1\" rowspan=\"1\">kg<\/td>\n<td colspan=\"1\" rowspan=\"1\">510 \/ 1020 \/ 2039<\/td>\n<td colspan=\"2\" rowspan=\"1\">5099<\/td>\n<td colspan=\"1\" rowspan=\"1\">10197<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" rowspan=\"1\">Accruacy class 1)2)<\/td>\n<td colspan=\"1\" rowspan=\"1\"><\/td>\n<td colspan=\"4\" rowspan=\"1\">C3\u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 C5<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" rowspan=\"1\">Min. dead load<\/td>\n<td>kg<\/td>\n<td colspan=\"4\" rowspan=\"1\">0<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" rowspan=\"1\">Rated output<\/td>\n<td>mV\/V<\/td>\n<td colspan=\"4\" rowspan=\"1\">2.0 \u00b1 0.002<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" rowspan=\"1\">Zero balance<\/td>\n<td>% of Emax<\/td>\n<td colspan=\"4\" rowspan=\"1\">\uff1c \u00b1 1<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" rowspan=\"1\">Repeatability error<\/td>\n<td>% of AL 3)<\/td>\n<td colspan=\"4\" rowspan=\"1\">\uff1c \u00b1 0.010\u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0\uff1c \u00b1 0.006<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" rowspan=\"1\">Creep; 30 minute<\/td>\n<td>% of AL<\/td>\n<td colspan=\"4\" rowspan=\"1\">\uff1c \u00b1 0.017\u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0\uff1c \u00b1 0.010<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" rowspan=\"1\">Min. dead load output return (DR); 30 min<\/td>\n<td>% of AL<\/td>\n<td colspan=\"4\" rowspan=\"1\">\uff1c \u00b1 0.017\u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0\uff1c \u00b1 0.010<\/td>\n<\/tr>\n<tr>\n<td colspan=\"1\" rowspan=\"2\">Temp. effect on<\/td>\n<td colspan=\"1\" rowspan=\"1\">Min. dead load output<\/td>\n<td colspan=\"1\" rowspan=\"1\">% of Emax\/\u2103<\/td>\n<td colspan=\"4\" rowspan=\"1\">\uff1c \u00b1 0.0020\u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0\uff1c \u00b1 0.0014<\/td>\n<\/tr>\n<tr>\n<td colspan=\"1\" rowspan=\"1\">Rated output 2)<\/td>\n<td colspan=\"1\" rowspan=\"1\">% of AL\/\u2103<\/td>\n<td colspan=\"4\" rowspan=\"1\">\uff1c \u00b1 0.0012\u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0\uff1c \u00b1 0.0007<\/td>\n<\/tr>\n<tr>\n<td colspan=\"1\" rowspan=\"3\">Temperature range<\/td>\n<td colspan=\"1\" rowspan=\"1\">Compensated<\/td>\n<td colspan=\"1\" rowspan=\"3\">\u2103(\u00b0F)<\/td>\n<td colspan=\"4\" rowspan=\"1\">-10 to +40 [+14 to +104]<\/td>\n<\/tr>\n<tr>\n<td colspan=\"1\" rowspan=\"1\">Operating<\/td>\n<td colspan=\"4\" rowspan=\"1\">-30 to +65 [-22 to +149]<\/td>\n<\/tr>\n<tr>\n<td colspan=\"1\" rowspan=\"1\">Safe storage<\/td>\n<td colspan=\"4\" rowspan=\"1\">-40 to +80 [-40 to +176]<\/td>\n<\/tr>\n<tr>\n<td colspan=\"1\" rowspan=\"2\">Excitation voltage<\/td>\n<td colspan=\"1\" rowspan=\"1\">Recommended<\/td>\n<td colspan=\"1\" rowspan=\"2\">V AC\/DC<\/td>\n<td colspan=\"4\" rowspan=\"1\">5 ~ 15<\/td>\n<\/tr>\n<tr>\n<td colspan=\"1\" rowspan=\"1\">Maximum<\/td>\n<td colspan=\"4\" rowspan=\"1\">15<\/td>\n<\/tr>\n<tr>\n<td colspan=\"1\" rowspan=\"2\">Terminal resistance<\/td>\n<td colspan=\"1\" rowspan=\"1\">Excitation<\/td>\n<td colspan=\"1\" rowspan=\"2\">\u03a9<\/td>\n<td colspan=\"4\" rowspan=\"1\">1100 \u00b1 15<\/td>\n<\/tr>\n<tr>\n<td colspan=\"1\" rowspan=\"1\">Output<\/td>\n<td colspan=\"4\" rowspan=\"1\">1000 \u00b1 3<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" rowspan=\"1\">Insulation resistance @50VDC<\/td>\n<td colspan=\"1\" rowspan=\"1\">M\u03a9<\/td>\n<td colspan=\"4\" rowspan=\"1\">\uff1e5000<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" rowspan=\"1\">Breakdown voltage<\/td>\n<td colspan=\"1\" rowspan=\"1\">V AC<\/td>\n<td colspan=\"4\" rowspan=\"1\">\uff1e500<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" rowspan=\"1\">Seal type \/ IP rating<\/td>\n<td colspan=\"1\" rowspan=\"1\"><\/td>\n<td colspan=\"4\" rowspan=\"1\">Hermetically welded \/ IP68 IP69k<\/td>\n<\/tr>\n<tr>\n<td colspan=\"1\" rowspan=\"2\">Load limit<\/td>\n<td colspan=\"1\" rowspan=\"1\">Safe<\/td>\n<td colspan=\"1\" rowspan=\"2\">% of Emax<\/td>\n<td colspan=\"4\" rowspan=\"1\">150<\/td>\n<\/tr>\n<tr>\n<td colspan=\"1\" rowspan=\"1\">Ultimate<\/td>\n<td colspan=\"4\" rowspan=\"1\">300<\/td>\n<\/tr>\n<tr>\n<td colspan=\"1\" rowspan=\"3\">Material<\/td>\n<td colspan=\"1\" rowspan=\"1\">Spring element<\/td>\n<td colspan=\"1\" rowspan=\"1\"><\/td>\n<td colspan=\"4\" rowspan=\"1\">Stainless steel\u00a0 \u00a0[ B760S: 17-4PH ]<\/td>\n<\/tr>\n<tr>\n<td colspan=\"1\" rowspan=\"1\">Strain gauge<\/td>\n<td colspan=\"1\" rowspan=\"1\"><\/td>\n<td colspan=\"4\" rowspan=\"1\">PEEK\u00a0 \u00a0[ B760S: HBK SG ]<\/td>\n<\/tr>\n<tr>\n<td colspan=\"1\" rowspan=\"1\">Cable<\/td>\n<td colspan=\"1\" rowspan=\"1\"><\/td>\n<td colspan=\"4\" rowspan=\"1\">\u03a65.6; 4-wire; PVC\u00a0 \u00a0[ B760S: PU ]<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" rowspan=\"1\">Cable length<\/td>\n<td colspan=\"1\" rowspan=\"1\">m<\/td>\n<td colspan=\"4\" rowspan=\"1\">10.0<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" rowspan=\"2\">Weight; approx<\/td>\n<td colspan=\"1\" rowspan=\"2\">kN<\/td>\n<td colspan=\"1\" rowspan=\"1\">5~20kN<\/td>\n<td colspan=\"1\" rowspan=\"1\">50kN<\/td>\n<td colspan=\"2\" rowspan=\"1\">100kN<\/td>\n<\/tr>\n<tr>\n<td colspan=\"1\" rowspan=\"1\">1.4<\/td>\n<td colspan=\"1\" rowspan=\"1\">2.9<\/td>\n<td colspan=\"2\" rowspan=\"1\">7.1<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" rowspan=\"1\">Fatigue life<\/td>\n<td colspan=\"1\" rowspan=\"1\">cycles @Emax<\/td>\n<td colspan=\"4\" rowspan=\"1\">\uff1e1,000,000<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" rowspan=\"1\">Deflection at Emax; approx<\/td>\n<td colspan=\"1\" rowspan=\"1\">mm<\/td>\n<td colspan=\"4\" rowspan=\"1\">\uff1c0.5<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" rowspan=\"1\">Barometric pressure effect on Zero Output<\/td>\n<td colspan=\"1\" rowspan=\"1\">Vmin\/kPa<\/td>\n<td colspan=\"4\" rowspan=\"1\">\uff1c1.0<\/td>\n<\/tr>\n<tr>\n<td colspan=\"1\" rowspan=\"2\">Mounting screw<\/td>\n<td colspan=\"1\" rowspan=\"1\">Size\/Grade<\/td>\n<td colspan=\"1\" rowspan=\"1\"><\/td>\n<td colspan=\"1\" rowspan=\"1\">M12 \/ A2-70<\/td>\n<td colspan=\"1\" rowspan=\"1\">M20 \/ A2-70<\/td>\n<td colspan=\"2\" rowspan=\"1\">M24 \/ A2-70<\/td>\n<\/tr>\n<tr>\n<td colspan=\"1\" rowspan=\"1\">Recommended torque<\/td>\n<td colspan=\"1\" rowspan=\"1\">N.m<\/td>\n<td colspan=\"1\" rowspan=\"1\">98<\/td>\n<td colspan=\"1\" rowspan=\"1\">275<\/td>\n<td colspan=\"2\" rowspan=\"1\">400<\/td>\n<\/tr>\n<tr>\n<td colspan=\"7\" rowspan=\"1\">Notes:<\/td>\n<\/tr>\n<tr>\n<td colspan=\"7\" rowspan=\"1\">1)\u00a0Error due to the combined effect of non-linearity and hysteresis<\/td>\n<\/tr>\n<tr>\n<td colspan=\"7\" rowspan=\"1\">2) The sum of errors due to Temperature Effect on Output comply with the requirements of OIML R60 and NIST HB44<\/td>\n<\/tr>\n<tr>\n<td colspan=\"7\" rowspan=\"1\">3) AL = Applied Load<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><img decoding=\"async\" src=\"https:\/\/www.weighingcell.com\/static\/upload\/image\/20240831\/1725070622963846.jpg\" \/><\/p>\n","protected":false},"excerpt":{"rendered":"<div class=\"scrollbox\">\n<div class=\"scrollbox\">\n<div class=\"scrollbox\">\n<div class=\"scrollbox\">\n<div class=\"scrollbox\">\n<div class=\"scrollbox\">\n<div class=\"scrollbox\">\n<div class=\"scrollbox\">\n<div class=\"scrollbox\">\n<p><strong>Product description\uff1a<\/strong><\/p>\n<p>The B560, B760S series are typical and high precision, low profile single-ended shear beam available in a wide range of capacities. Full stainless steel construction and complete hermetic sealing ensures reliable accuracy and robustness in harsh industrial applications. The B560S, B760S are the ideal load cell for high precision weighing platforms with bolts by 2pcs through-holes firmly at end, meanwhile the force would be applied from the self-aligning level-pin settled into the blind hole at the other end vertically.<\/p>\n<p><strong>Main Features:<\/strong><\/p>\n<p>\u2022 Material: high-quality stainless steel<\/p>\n<p>\u2022 Great long-term stability.<\/p>\n<p>\u2022 Rated Capacities: 5KN~100KN<\/p>\n<p>\u2022 IP Rating: IP68<\/p>\n<p>\u2022 Suitable for platform scales, dosing system and process control in chemical, food, pharmaceutical and other industries.<\/p>\n<p>\u2022 High precision by OIML R60 C5, high reliability.<\/p>\n<p>\u2022 B760S with 17-4PH material and PEEK strain gauge from HBK.<\/p>\n<\/div>\n<p>Category: Shear Beam<\/p>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n","protected":false},"featured_media":294182,"template":"","meta":[],"product_brand":[2448],"product_cat":[413],"product_tag":[857],"class_list":{"0":"post-294185","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_brand-utilcell-ru","7":"product_cat---s---","8":"product_tag----ru","10":"first","11":"instock","12":"taxable","13":"shipping-taxable","14":"product-type-simple"},"aioseo_notices":[],"_links":{"self":[{"href":"https:\/\/ksensors.co.kr\/ru\/wp-json\/wp\/v2\/product\/294185","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/ksensors.co.kr\/ru\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/ksensors.co.kr\/ru\/wp-json\/wp\/v2\/types\/product"}],"version-history":[{"count":0,"href":"https:\/\/ksensors.co.kr\/ru\/wp-json\/wp\/v2\/product\/294185\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/ksensors.co.kr\/ru\/wp-json\/wp\/v2\/media\/294182"}],"wp:attachment":[{"href":"https:\/\/ksensors.co.kr\/ru\/wp-json\/wp\/v2\/media?parent=294185"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/ksensors.co.kr\/ru\/wp-json\/wp\/v2\/product_brand?post=294185"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/ksensors.co.kr\/ru\/wp-json\/wp\/v2\/product_cat?post=294185"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/ksensors.co.kr\/ru\/wp-json\/wp\/v2\/product_tag?post=294185"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}