{"id":292100,"date":"2025-12-18T09:38:12","date_gmt":"2025-12-18T00:38:12","guid":{"rendered":"https:\/\/ksensors.co.kr\/product\/utilcell-sl552-single-point-load-cell\/"},"modified":"2025-12-18T09:38:12","modified_gmt":"2025-12-18T00:38:12","slug":"utilcell-sl552-single-point-load-cell","status":"publish","type":"product","link":"https:\/\/ksensors.co.kr\/ru\/product\/utilcell-sl552-single-point-load-cell\/","title":{"rendered":"UTILCELL \/ SL552 \/ Single Point Load Cell"},"content":{"rendered":"<h1>SL552 Dosage Scale Load Cell<\/h1>\n<table class=\"tt2\" width=\"100%\">\n<tbody>\n<tr class=\"firstRow\">\n<td width=\"50%\"><img decoding=\"async\" title=\"1710118289118460.jpg\" src=\"https:\/\/www.weighingcell.com\/static\/upload\/image\/20240311\/1710118289118460.jpg\" alt=\"SL552.JPG\" \/><\/td>\n<td>\n<h2>Product Features<\/h2>\n<p>SL552 load cell adopts cantilever structure design, pressure bearing, easy and flexible installation and use. It has good sealing and moisture-proof performance. It has high precision and high stability, small size, beautiful appearance, and high dynamic response frequency. Shock resistance, overload resistance, simple installation, save the difficulty of on-site installation work.<\/p>\n<p>Each sensor sends out a signal separately and is processed by a separate module. If multiple sensor group scales are used, there is no need to worry about the influence of partial load, thus providing the measurement accuracy of the overall weighing system.<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<div class=\"row\">\n<div class=\"col-md-6\">\n<h2>Technical Specifications<\/h2>\n<table class=\"table1\" width=\"100%\">\n<tbody>\n<tr class=\"firstRow\">\n<td>Specification<\/td>\n<td>Technical Indicators<\/td>\n<\/tr>\n<tr>\n<td>Capacity<\/td>\n<td>6,10,20,30,40kg<\/td>\n<\/tr>\n<tr>\n<td>Rated Output<\/td>\n<td>2.0\u00b110%mV\/V<\/td>\n<\/tr>\n<tr>\n<td>Zero Balance<\/td>\n<td>\u00b12%mV\/V<\/td>\n<\/tr>\n<tr>\n<td>Creep<\/td>\n<td>\u22640.03%F.S.<\/td>\n<\/tr>\n<tr>\n<td>Non-Linearity<\/td>\n<td>\u22640.02%F.S.<\/td>\n<\/tr>\n<tr>\n<td>Hysteresis<\/td>\n<td>\u22640.02%F.S.<\/td>\n<\/tr>\n<tr>\n<td>Repeatability<\/td>\n<td>\u22640.017%F.S.<\/td>\n<\/tr>\n<tr>\n<td>Input Inpedance<\/td>\n<td>387\u00b110\u03a9<\/td>\n<\/tr>\n<tr>\n<td>Output Inpedance<\/td>\n<td>350\u00b15\u03a9<\/td>\n<\/tr>\n<tr>\n<td>Temp. effect on output<\/td>\n<td>0.025%F.S.\/10\u2103<\/td>\n<\/tr>\n<tr>\n<td>Temp. effect on zero<\/td>\n<td>0.025%F.S.\/10\u2103<\/td>\n<\/tr>\n<tr>\n<td>Insulation Inpendance<\/td>\n<td>\u22655000M\u03a9\/100V(DC)<\/td>\n<\/tr>\n<tr>\n<td>Reconnended Excitation<\/td>\n<td>10V<\/td>\n<\/tr>\n<tr>\n<td>Maximum Excitation<\/td>\n<td>15V<\/td>\n<\/tr>\n<tr>\n<td>Conpensated Temp Range<\/td>\n<td>-10~40\u2103<\/td>\n<\/tr>\n<tr>\n<td>Operating Temp Range<\/td>\n<td>-20~65\u2103<\/td>\n<\/tr>\n<tr>\n<td>Safe Overload<\/td>\n<td>150% F.S.<\/td>\n<\/tr>\n<tr>\n<td>Ultimate Overload<\/td>\n<td>200% F.S.<\/td>\n<\/tr>\n<tr>\n<td>Cable Size<\/td>\n<td>4X3m<\/td>\n<\/tr>\n<tr>\n<td>Material<\/td>\n<td>Stainless steel<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<div class=\"col-md-6\">\n<h2>Product Dimensions<\/h2>\n<h4>Installation size<\/h4>\n<p><img decoding=\"async\" title=\"1710118296184767.jpg\" src=\"https:\/\/www.weighingcell.com\/static\/upload\/image\/20240311\/1710118296184767.jpg\" alt=\"SL552-1.JPG\" \/><\/p>\n<h4>Load Direction<\/h4>\n<p><img decoding=\"async\" title=\"1710118302116411.jpg\" src=\"https:\/\/www.weighingcell.com\/static\/upload\/image\/20240311\/1710118302116411.jpg\" alt=\"SL552-2.JPG\" \/><\/p>\n<h4>Wiring Diagram<\/h4>\n<p><img decoding=\"async\" title=\"1710118308183176.jpg\" src=\"https:\/\/www.weighingcell.com\/static\/upload\/image\/20240311\/1710118308183176.jpg\" alt=\"SL552-3.JPG\" \/><\/p>\n<\/div>\n<\/div>\n<h2>Accurate measurement with matching display<\/h2>\n<p>The output of the force measuring and weighing sensor itself is an MV signal, which needs to be amplified and convertedto display numerical values or output signals to the upper computer, PLC, etc.<\/p>\n","protected":false},"excerpt":{"rendered":"<div class=\"scrollbox\">\n<div class=\"scrollbox\">\n<div class=\"scrollbox\">\n<div class=\"scrollbox\">\n<div class=\"scrollbox\">\n<p>Signle Point Load Cell<\/p>\n<p>L 130mm*W 22mm*H 30mm<\/p>\n<p>Capacity: 6,10,20,30,40kg<\/p>\n<\/div>\n<p>Category: Single Point Load Cell<\/p>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n","protected":false},"featured_media":292097,"template":"","meta":[],"product_brand":[2448],"product_cat":[430],"product_tag":[860],"class_list":{"0":"post-292100","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_brand-utilcell-ru","7":"product_cat-430","8":"product_tag----ru","10":"first","11":"instock","12":"taxable","13":"shipping-taxable","14":"product-type-simple"},"aioseo_notices":[],"_links":{"self":[{"href":"https:\/\/ksensors.co.kr\/ru\/wp-json\/wp\/v2\/product\/292100","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/ksensors.co.kr\/ru\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/ksensors.co.kr\/ru\/wp-json\/wp\/v2\/types\/product"}],"version-history":[{"count":0,"href":"https:\/\/ksensors.co.kr\/ru\/wp-json\/wp\/v2\/product\/292100\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/ksensors.co.kr\/ru\/wp-json\/wp\/v2\/media\/292097"}],"wp:attachment":[{"href":"https:\/\/ksensors.co.kr\/ru\/wp-json\/wp\/v2\/media?parent=292100"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/ksensors.co.kr\/ru\/wp-json\/wp\/v2\/product_brand?post=292100"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/ksensors.co.kr\/ru\/wp-json\/wp\/v2\/product_cat?post=292100"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/ksensors.co.kr\/ru\/wp-json\/wp\/v2\/product_tag?post=292100"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}