Zemic / HM8 Load Cell Zemic Shear Beam Load Cells



Share it:

HM8 Load Cell Zemic Shear Beam Load Cells

Product Description

图片1

Short Description:

◎Nickel plated alloy steel IP68 shear beam load cell;

◎Hermetically sealed;

◎Suitable for electronic platform scales, hopper scales;

◎High accuracy;

Dimensions in mm:

图片2

Dimension
Capacity
0.5t 1t 1.5t-2t 2.5t 3t-5t 10t
L 130 (5.12) 130 (5.12) 130 (5.12) 171.5 (6.75) 171.5 (6.75) 222.3
L1 15.8 (0.62) 15.8 (0.62) 15.8 (0.62) 19.1 (0.75) 19.1 (0.75) 25.4 (1.00)
L2 25.4 (1.00) 25.4 (1.00) 25.4 (1.00) 38.1 (1.50) 38.1 (1.50) 50.8 (2.00)
L3 76.2 (3.00) 76.2 (3.00) 76.2 (3.00) 95.3 (3.75) 95.3 (3.75) 120.3 (4.74)
L4 53.7 (2.11) 53.7 (2.11) 54.2 (2.13) 76.2 (3.00) 77.2 (3.04) 101.6 (4.00)
H 31.8 (1.25) 31.8 (1.25) 31.8 (1.25) 38.1 (1.50) 38.1 (1.50) 50.8 (2.00)
H1 15.8 (0.62) 15.8 (0.62) 15.8 (0.62) 18.8 (0.74) 18.8 (0.74) 25.4 (1.00)
H2 26 (1.02) 28 (1.10) 34 (1.34)
B 31.8 (1.25) 31.8 (1.25) 31.8 (1.25) 38.1 (1.50) 38.1 (1.50) 50.8 (2.00)
ΦD 13.5 (0.53) 13.5 (0.53) 13.5 (0.53) 19.8 (0.78) 19.8 (0.78) 26 (1.02)
Φd 13.5 (0.53) 13.5 (0.53) 13.5 (0.53) 19.8 (0.78) 19.8 (0.78) 26 (1.02)
M M12 M12 M12 M18 M18 M24

Available models:

Capacity Accuracy Full article description
500kg C3 Excluded from OIML HM8C-C3-500kg-4B
1t C3 Excluded from OIML HM8C-C3-1t-4B
1.5t C3 Excluded from OIML HM8C-C3-1.5t-4B
2t C3 Excluded from OIML HM8C-C3-2t-4B
3t C3 Excluded from OIML HM8C-C3-3t-4B
5t C3 Excluded from OIML HM8C-C3-5t-4B
10t C3 Excluded from OIML HM8C-C3-10t-4B

Specification:

Accuracy class C3
Output sensitivity ( = FS ) mV/V 2.0 ± 0.004
Maximum capacity ( Emax ) t 0.5, 1, 1.5, 2, 3, 5, 10
Maximum number of load cell intervals ( nLC ) 3000
Ratio of minimum LC verification interval Y = Emax / vmin 10000
Combined error %FS ± 0.0230
Minimum dead load of Emax 0%
Safe overload of Emax 150 %
Ultimate overload of Emax 300 %
Zero balance %FS ± 1.5
Excitation, recommended voltage V 5 ~ 12( DC )
Excitation maximum V 18( DC )
Input resistance Ω 350 ± 3.5
Output resistance Ω 351 ± 2.0
Insulation resistance ≥ 5000 ( 50VDC )
Compensated temperature -10 ~+40
Operating temperature -35 ~ +65
Storage temperature -40 ~ +70
Element material Nickel plated alloy steel
Ingress protection (acc. to EN 60529) IP68
Recommended torque on fixation N.m M12: 100 M18:300 M24:750
ATEX classification (optional) II1G Ex ia IIC T4 II1D Ex iaD 20 T73℃ C II3G Ex nL IIC T4

 

Wiring:

◎Shielded, 4 conductor cable;

◎Cable diameter: Φ5mm;

◎Standard cable length for 500kg -2t:4m and for 3t — 10t: 6m;

◎Shield not connected to element;