BM11 Bending Beam Load Cell Zemic Load Cell

Product Description

图片1

Short Description:

◎Stainless steel IP68 single ended bending beam;

◎Hermetically sealed;

◎Suitable for pallet, platform and small hopper scales;

◎High accuracy;

◎Current calibrated (sc-option);

 

Dimensions in mm:

图片2

Capacity(kg)
Dimension
5,10,20,30,50,100,150,200 250,300,350,500
d 8.2 (0.32) 10.3 (0.41)
D 23 (0.91) 24 (0.94)
H 20 (0.79) 19 (0.75)

 

Available models:

Capacity Accuracy Full article description Capacity Accuracy Full article description
5kg C3 Excluded from OIML BM11-C3-5kg-3B-SC 100 kg C3/C4 BM11-C3/C4-100kg-3B-SC
10kg C3/C4 BM11-C3/C4-10kg-3B-SC 200 kg C3/C4 BM11-C3/C4-200kg-3B-SC
20kg C3/C4 BM11-C3/C4-20kg-3B-SC 250 kg C3/C4 BM11-C3/C4-250kg-3B-SC
30kg C3/C4 BM11-C3/C4-30kg-3B-SC 350 kg C3/C4 BM11-C3/C4-350kg-3B-SC
50kg C3/C4 BM11-C3/C4-50kg-3B-SC 500kg C3/C4 BM11-C3/C4-500kg-3B-SC

Specification:

Accuracy class C3 OIML R60 C3 OIML R60 C4
Output sensitivity ( = FS ) mV/V 2.0 ± 0.02
Maximum capacity ( Emax ) klb 5 10,20,30,50,100,200,250,350,500
Maximum number of load cell intervals ( nLC ) 3000 3000 4000
Ratio of minimum LC verification interval Y = Emax / vmin 10000 15000
Combined error %FS ± 0.023 ± 0.0174
Minimum dead load of Emax 0%
Safe overload of Emax 150 %
Ultimate overload of Emax 300 %
Zero balance %FS ± 1.0
Excitation, recommended voltage V 5 ~ 12( DC )
Excitation maximum V 18( DC )
Input resistance Ω 460 ± 50
Output resistance Ω 350 ± 3.5
Insulation resistance ≥ 5000 ( 50VDC )
Compensated temperature -10 ~+40
Operating temperature -35 ~ +65
Storage temperature -40 ~ +70
Element material Stainless steel
Ingress protection (according to EN 60529) IP68
Recommended torque on fixation N.m M8:25 M10:50
ATEX classification (optional) II1G Ex ia IIC T4 II1D Ex iaD 20 T73℃ C II3G Ex nL IIC T4

 

Wiring:

◎Shielded, 6 and 4 conductor cable for all capacities;

◎Cable diameter: Φ 5mm;

◎Standard cable length for 4 conductor cable: 3m and for 6 conductor cable: 6m;

◎Shield not connected to element;