UTILCELL / SP532S SINGLE POINT LOAD CELL


Product description:

SP532S is a typical and standard stainless single point load cell that is compact, low capacity and ideal for a wide range of weighing equipment. Environmentally sealed with potting black glue compound to ensure reliability and durability. The industry standard size and mounting hole configuration makes the SP532S is suitable for new equipment manufacturer or as a replacement for existed weighing equipment.

Main Features:

• Material: stainless steel

• Rated Capacities: 50kg~300kg

• OIML R60, NTEP HB44, CPA, CE and RoHS certified

• IP Rating: IP67

• Environmentally sealed by potting special black glue, also strain gauge is double-sealed with another special nanoscale coating.

• Suitable for bench scales, packaging and grading machines, bag filling equipment, bottle filling machinery and other process weighing, etc.

• Max platform size: 300*350mm

Category: Single Point


Share it:

SP532S SINGLE POINT LOAD CELL

Parameter Units Specifications
Model No. SP532S
Rated capacity (Emax) kg 50 / 100 / 300
Accuracy class 1) 2) C3 / C6
Min. dead load kg 0
Rated output mV/V 2.0 ± 0.2
Zero balance % of Emax < ± 2
Repeatability error % of AL 3) C3: < ± 0.010 / C6: < ± 0.005
Creep; 30 min % of AL C3: < ± 0.017 / C6: < ± 0.0083
DR; 30 min % of AL C3: < ± 0.017 / C6: < ± 0.0083
Temp. effect on Min. dead load output % of Emax/℃ C3: < ± 0.0020 / C6: < ± 0.0014
Rated output 2) % of AL/℃ C3: < ± 0.0012 / C6: < ± 0.0006
Temperature range Compensated ℃ (°F) -10 ~ +40 [14 ~ 104]
Operating -40 ~ +65 [40 ~ 149]
Safe storage -40 ~ +80 [-40 ~ 176]
Excitation voltage Recommended V AC/DC 5 ~ 15
Maximum 15
Terminal resistance Excitation Ω 384 ± 5
Output 350 ± 3
Insulation resistance @50VDC > 5000
Breakdown voltage V AC > 500
Seal type / IP rating Surface potting (black silicone, coated strain gauge) / IP67
Load limit Safe % of Emax 150
Ultimate 300
Material Spring element Stainless steel, electropolished
Cable connector Stainless steel, electropolished
Cable Ø5.6 · 4-wire · PVC
Cable length m 3.0
Maximum platform size mm 400 × 500
Off-center load error (OIML R76) % of AL/cm < ± 0.0025
Weight kg 1.4
Fatigue life cycles @Emax > 1,000,000
Deflection at Emax mm < 0.5
Barometric pressure effect on zero Vmin/kPa < 1.0
Mounting screw Size / Grade M6 / 8.8
Recommended torque N·m 20.0
Notes:
1) Error due to combined non-linearity and hysteresis
2) Temperature effects comply with OIML R60 and NIST HB44
3) AL = Applied Load