Product Features:
This product adopts components such as feet, tumblers, upper and lower inducers, which are easy to install and suitable for weighing systems such as electronic platform scales with single and double layer countertops.
Range(t) | Size: mm | |||||
L | L1 | H | H1 | H2 | F | |
0.3-3 | 130 | 25.4 | 78 | 66 | 32 | 94 |
5 | 171.5 | 38 | 38 | 107 | ||
7.5-10 | 222.2 | 50.8 | 50.8 | 132 |
Technical Parameters: Rated
Load: 300kg to 10T
Accuracy Class: C2 and C3
Sensitivity: 2.0 ±0.002% and 3.0 ±0.002% mV/V
Nonlinear (with hysteresis): ±0.02%F.S
Repeatability: ±0.02%F.S
Creep (30 min): ±0.02%F.S
Temperature Effect on Zero Point: ±0.02% F.S/10°C
Temperature Effect on Sensitivity: ±0.02% F.S/10°C
Operating Temperature: -30 to 70
Temperature Compensation Range: -20 to 60°C
Safe Load: 150% F.S
Ultimate Load: 200% F.S
Breaking Load: 300% F.S
Input Resistance: 400 ± 20Ω
Output Resistor : 350 ± 2Ω
Insulation Resistance: ≥5000MΩ Zero
Point Balance: ±1% F.S
Recommended Operating Voltage: 10V DC
Maximum Operating Voltage: 15V DC
Material: Stainless Steel/Alloy Steel
Cable Length: 3,5,9m
Protection Level: IP67
Reference Standard: GB/T7551-2008 OIMLR60
Wiring Method:
Input +: Red
Input -: Black
Output + : Green
Output -: White