Категория: Метка: Бренд:

Right / T722 / Single Point Load Cell


Widely used in process weighing systems in industries such as stainless steel waterproof scales, chemical waterproof pharmaceuticals, etc.

Material: sstainless steel, Good stability
definition: High overall sensitivity Four corner deviations have been compensated


Share it:

T722 Single Point Load Cell

Installation dimensions

T722 installation drawings

Parameters

Specifications

Technique

Capacity

50,100,200,300,500,1000 kg

Sensitivity

2.0 ± 0.002 mV / V

Zero Balance

≤1% F.S.

Non-linearity

≤0.017 % F.S.

Hysteresis Error

≤0.017 % F.S.

Repetition

≤0.01% F.S.

Creep (30 min)

≤0.017 % F.S.

Temp. Effect on sensitivity (TKc)

≤0.002 % F.S. / 10 ℃

Temp. Effect on zero balance (TKo)

≤0.002 % F.S. / 10 ℃

Input Resistance

380 ± 20Ω

Output Resistance

350 ± 10Ω

Insulating Resistance

≥5000MΩ / 100VDC

Excitation Voltage

5 V

Max. Excitation Voltage

15 V

Compensation Range

-10 ~ 40 ℃

Service Temperature Range

-40 ~ 65 ℃

Limit load (E L)

150% F.S.

Breaking load (E d)

300% F.S.

Cable size

φ6.3 × 2500 mm

Weight (G), approx.

0.9 kg

Material (Measuring element)

Stainless Steel

IP Class

IP67

Features and Applications

Stainless steel material, strong stability

High comprehensive sensitivity and compact structure

Four corner deviations have been compensated

Good long-term stability

Mainly used for stainless steel waterproof scales, process weighing in the chemical waterproof pharmaceutical industry

 

Load Direction

T722 force mode

Wiring Code

Wiring regulations