T707 Weighing Load Cell

Dimension

T707 installation dimensions

Parameters

Specifications

Technique

Capacity

300g, 500g, 1, 2, 3, 5 kg

Accuracy

C3

Zero Balance

1.0 ± 10% mV / V (300g, 500g)

2.0 ± 10% mV / V (1 ~ 5Kg)

Non-linearity

± 2% F.S.

Hysteresis Error

0.015% F.S.

Repetition

0.015% F.S.

Creep (30 min)

0.0166% F.S.

Temp. Effect on sensitivity (TKc)

0.017% F.S. / 10 ℃

Temp. Effect on zero balance (TKo)

0.02% F.S. / 10 ℃

Input resistance

380 ± 40 Ω

Output resistance

380 ± 40 Ω

Insulating Resistance

≥5000 MΩ / 100VDC

Excitation Voltage

5 ~ 15 V

Max. Excitation Voltage

20 V

Compensation Range

-10 ~ 40 ℃

Service Temperature Range

-25 ~ 70 ℃

Limit load (E L)

150% F.S.

Breaking load (E d)

300% F.S.

Cable size

φ4 × 400 mm

Weight (G), approx.

0.1 kg

Material (Measuring element)

Aluminum alloy

IP Class

IP65

Features and Applications

Aluminum alloy material

High precision and strong anti-eccentricity

Easy to install, IP 65

Main electronic scales, counting scales, electronic balances and various industrial weighing systems, etc.

 

Load Direction

T707-2

Wiring Code

Wiring regulations