GBS805 Rail truck scale bridge type weight sensor
What is specifications of GBS805 Load cell?
| Application | Weighbridge/floor scales |
| Capacity | 10,20,30t |
| Rated output | 2.0±0.004mv/v |
| Accuracy class | C3 |
| Maximum number of verification intervals | 3000Nmax |
| Minimum load cell verification intervals | Emax/7500 Vmin |
| Comprehensive error | ≤±0.020%RO |
| Creep | 0.016%RO/30min |
| Temp. Effect of span | 0.0016%RO/℃ |
| Temp. Effect of zero | 0.002%RO/℃ |
| Zero balance | ±1.0%RO |
| Input resistance | 750±5Ω |
| Output resistance | 700±3Ω |
| Insulation resistance | 5000MΩ(50V) |
| Recommended excitation voltage | 10-15V |
| Compensated temp. range | -10~40℃ |
| Operating temp. range | -35~80℃ |
| Safe overload | 150%RO |
| Ultimate overload | 200%RO |
| load cell material | Alloy steel/ stainless steel |
| Connecting cable | ∅5.7*8-16m |
| Connecting way | Red: Exc + Black:Exc — Green: Sig + White:Sig- |
What is dimension of GBS805 Load cell?