Models

FA5123

Features

Accuracy:C3/C4
IP:IP67
Material:Stainless steel

Dimensions

Specifications

Item Unit C3 Specification C4 Specification
Maximum Capacity (Emax) kg 5, 7, 8, 10, 15, 20, 30, 50, 75, 100, 150, 200
Accuracy Class – OIML R60 C3 OIML R60 C4
Max. Number of Intervals (nLC) nmax 3000 4000
Min. Verification Interval Ratio (Y) – Emax / 10000Vmin Emax / 15000Vmin
Combined Error %FS ≤ ±0.020 ≤ ±0.018
Creep (30min) %FS ≤ ±0.016 ≤ ±0.012
Temp. Effect on Sensitivity %FS / 10℃ ≤ ±0.011 ≤ ±0.009
Temp. Effect on Zero %FS / 10℃ ≤ ±0.015 ≤ ±0.010
Output Sensitivity (=FS) mV/V 2.0 ± 0.2 2.0 ± 0.2
Input Resistance Ω 384 ± 4 384 ± 4
Output Resistance Ω 350 ± 3.5 350 ± 3.5
Insulation Resistance MΩ / 50VDC ≥ 5000 ≥ 5000
Zero Balance %FS ≤ ±1.5 ≤ ±1.5
Compensated Temp. Range ℃ -10 ~ +40 -10 ~ +40
Operating Temp. Range ℃ -35 ~ +70 -35 ~ +70
Recommended Excitation Voltage VDC 5 ~ 12 5 ~ 12
Maximum Excitation Voltage VDC 18 18
Safe Overload %FS 150 150
Ultimate Overload %FS 300 300
Corner Correction %load/100mm ≤ 0.02 ≤ 0.02
Recommended Torque on Fixation N·m 10 10
ATEX Classification (Optional) – II1G Ex ia IIC T4II1D Ex iaD20 T73℃II3G Ex nL IIC T4 Same as C3
Cable Diameter mm Φ5 Φ5
Standard Cable Length m 1 1
Wiring Color Code – Green: Input+Blue: Sense+White: Output+Red: Output−Black: Input−Yellow: Sense−Shield: Transparent Same as C3

본 게시물은 케이센서스에 저작권이 있습니다.

무단으로 전제 및 도용 시 법적으로 처벌 될 수 있습니다.


Copyright 2025. 케이센서스(KSENSORS) Co. All rights reserved.