CALT / CAX60 / Canbus 2.0 Многоборотный абсолютный энкодер с параллельным выходом


  • Multi-turn absolute encoder (mechanical gear set circle counting)
  • Detection method: magnetoelectric encoder, Hall principle
  • Operating voltage: 10…30Vdc polarity protected
  • Output signal: Canbus 2.0B standard frame or extended frame
  • Programmable, intelligent absolute encoder, professional setting software, user-friendly operation
    With setting line, easy to install and debug
  • Resolution: ≤16 bits, up to 65536 lines (order selection)
  • Laps: 4096 laps
  • Outer diameter 60mm, inner hole/shaft diameter 6-15mm optional
  • Protection class: shell IP67 shaft IP65
  • Vibration and shock: 20g, 10~2000Hz; 100g, 6ms
  • Allowable speed: 6000 rpm
  • Software and hardware can be customized according to actual needs

Share it:

Specifications

Mechanical parameters Electrical parameters
maximum speed 6000 rpm Operating Voltage 10-30Vdc (5Vdc can be customized)
Spindle load Axial 40N, Radial 100N current consumption < 50mA (24Vdc) no load
impact resistance 1000m/s²(6ms), equal to 100g output signal CAN 2.0B protocol standard frame or extended frame
Anti-vibration 200m/s²(10-2000Hz), equal to 20g Linear resolution 1/4096FS-65536FS
Allow axial play ±1.5mm Maximum working laps 4096 laps (256 laps/64 laps optional)
Allow radial runout ±0.2mm Repeatability Less than 2Bit
external structure 60mm OD, solid shaft, blind hole shaft Operating temperature -40℃~85℃
Connection Type 8-core shielded cable or aviation plug Storage temperature -40℃~85℃

Wiring diagram

Function Vcc GND RS485A(parameter setting) RS485B (parameter setting) CAN H CAN L direction shield
colour Brown White green yellow pink black blue Net (thick red)

Note: 1. Use of direction line (blue)

Connect the blue wire to a high level (that is, the encoder power supply is positive), and the encoder output value is counterclockwise (CCW).

Connect the blue line to low level (or leave it in the air), the encoder output value is clockwise (CW)

Mechanical dimension drawing

Clamping synchro flange (optional for cable output or plug output)

Synchronous flange/servo flange (cable output or plug output optional)

Blind Hole/Half Through Hole Flange (Cable output or plug output optional)

Absolute encoder parameter setting
The encoder is to set the communication frequency, address and resolution of CAN through our company’s special RS485 communication setting software.

The baud rate of RS485 communication is fixed at 115200.

Frame format: 8 data bits, 1 stop bit, no parity, no control flow

For example: