Technical parameters
| Parameter | Value / Description |
|---|---|
| Static accuracy | ±0.1% FSO |
| Resolution | 0.025% FSO |
| Conversion rate | 100 kHz max |
| Output/update rate (RS‑232) | 1.5–2.5 readings/min |
| Output/update rate (RS‑485) | 20–30 readings/s |
| Output/update rate (CAN bus) | 3–4 readings/s |
| Standard pressure ranges | 0–5, 10, 25, 30, 50, 75, 100, 200, 500, 750, 1,000, 1,500, 2,000, 3,000, 5,000, 7,500, 10,000, 15,000, 20,000, 25,000, 30,000 PSIA / PSIG / PSID |
| Proof pressure | 150% of rated range |
| Burst pressure | 200% of rated range |
| Pressure ports | 1/4″ NPT female or male (standard); 7/16″‑20 MS33649‑4 (female); 7/16″‑20 MS33656‑4 (male); AE F250‑C, 9/16″‑18 UNF (for ranges >15,000 psi) |
| Digital outputs | RS‑232, RS‑485 |
| Measurement buffer capacity | 131,072 readings |
| Data retention | >10 years |
| Power requirement | 8–40 VDC, 200 mW |
| Compensated temperature range | –35 to 76 °C |
| Operating temperature range | –40 to 85 °C |
| Weight | 255 g |
| Natural frequency | ≈3 kHz at 5 psi; ≈150 kHz at 30 kpsi |
Dimensions