KD80s/KD80sHT S-type Force Sensors
Technical
| Mechanical Characteristics | |||||
|---|---|---|---|---|---|
| Calibration method | Pressure & tensile force | ||||
| Material | Stainless steel | ||||
| Range | kg | 50,100,250,500,1k,2.5k,5.0k,7.5k,10k | |||
| Safe overload | %FS | 150 | |||
| Breaking overload | %FS | 300 | |||
| Maximum lateral load | %FS | 100 | |||
| Electrical Characteristics | |||||
| Sensitivity | mV/V @ FS | 3.3±0.3 | |||
| Zero signal | mV/V | < 0.05 | |||
| Excitation voltage—MAX | V | 10 | |||
| Input resistance | Ohm | 390 ±15 | |||
| Output resistance | Ohm | 350 ±3.5 | |||
| Insulation resistance | Ohm | > 5×109 | |||
| Cable length | m | 6 | |||
| Accuracy Data | |||||
| Accuracy class (OIML R60 standard) | CC | C1 | C2 | C3 | |
| Maximum number of divisions | 1000 | 2000 | 3000 | ||
| Minimum number of divisions | SN/4500 | SN/6000 | SN/9000 | ||
| Combined error | % SN | < ±0.05 | < ±0.03 | < ±0.023 | < ±0.02 |
| Zero output | % FN | < ±0.02 | < ±0.02 | < ±0.01 | < ±0.01 |
| Creep within 30 minutes | % SN | < ±0.06 | < ±0.049 | < ±0.0245 | < ±0.0167 |
| Zero temperature drift | % FN / 5°C | < ±0.025 | < ±0.0140 | < ±0.0112 | < ±0.0070 |
| Sensitivity temperature drift | % SN / 5°C | < ±0.025 | < ±0.0085 | < ±0.0060 | < ±0.0050 |
| Temperature | |||||
| Operating temperature range | °C | -10… +40 | |||
| Service temperature range | °C | -40 … +85 | |||
Dimensions