Zemic / H3 S Type Load Cell Zemic Load Cell



Share it:

H3 S Type Load Cell Zemic Load Cell

Product Description

图片1

Short Description:

◎Nickel plated alloy steel IP67 “S” type load cell;

◎Tension and compression applications;

◎Suitable for hanging, hopper and other weighing devices;

◎Also available in imperial capacities and dimensions;

Available models:

Capacity Accuracy Full article description
25kg C3 Excluded from OIML H3-C3-25kg-3B
50kg C3 Excluded from OIML H3-C3-50kg-3B
100kg C3/C4 H3-C3/C4-100kg-3B
150kg C3/C4 H3-C3/C4-150kg-3B
200kg C3/C4 H3-C3/C4-1-0kg-3B
250kg C3/C4 H3-C3/C4-250kg-3B
300kg C3/C4 H3-C3/C4-300kg-3B
500kg C3/C4 H3-C3/C4-500kg-3B
600kg C3/C4 H3-C3/C4-600kg-3B
750kg C3/C4 H3-C3/C4-750kg-3B
1t C3/C4 H3-C3/C4-1t-3B
1.5t C3/C4 H3-C3/C4-1.5t-3B
2t C3/C4 H3-C3/C4-2t-3B
2.5t C3/C4 H3-C3/C4-2.5t-3B
3t C3 Excluded from OIML H3-C3-3t-3B
5t C3 Excluded from OIML H3-C3-5t-3B
7.5t C3 Excluded from OIML H3-C3-7.5t-3B
10t C3 Excluded from OIML H3-C3-10t-3B
15t C3 Excluded from OIML H3-C3-15t-3B
20t C3 Excluded from OIML H3-C3-20t-3B
30t C3 Excluded from OIML H3-C3-30t-3B

Specification:

Accuracy class OIML R60 C3 OIML R6O C4 C3
Output sensitivity(= FS) mV/V 2.0 ± 0.004
Maximum capacity ( Emax ) t 0.1,0.15,0.2,0.3,0.5,0.6,
0.75,1.0,1.5,2.0,2.5,
0.025,0.05,3.0,5.0,7.5, 10,15,20,30
Maximum number of load cell intervals (nLC) 3000 4000 3000
Ratio of minimum LC verification interval Y = Emax / Vmin 10000 20000 10000
Combined error %FS ±0.020 ± 0.018 ±0.020
Minimum dead load kg 0
Safe overload of Emax 150%
Ultimate overload of Emax 300%
Zero balance %FS ±1.5
Excitation, recommended voltage V 5~12(DC)
Excitation maximum V 18(DC)
Input resistance Ω 350±3.5
Output resistance Ω 351±2.0
Insulation resistance ≥ 5000(50VDC)
Compensated temperature -10~+40
Operating temperature -35~+65
Storagetemperature -40~+70
Element material Nickel plated alloy steel
lngress protection (according to EN 60529) IP67
Recommended torque on fixation N.m M8:25 M10:50 M12:75 M20:450 M33:750 M42:1450
ATEX classification (optional) Ⅱ1G Ex ia ⅡC T4 Ⅱ1D Ex iaD 20 T73℃ Ⅱ3G Ex nL ⅡC T4

 Dimensions in mm:

图片2

Dimension

Capacity

H L W1 M H1
25kg -50kg 76.2(3.0) 50.8(2.0) 12.7(0.5) M8 15.7(0.62)
0.1t.0.15t 76.2(3.0) 50.8(2.0) 19(0.75) M10×1.5 15.3(0.60)
0.2t~0.75t 76.2(3.0) 50.8(2.0) 19(0.75) M12×1.75 15.1(0.59)~12.5 (0.48)
1,1.5t 76.2(3.0) 50.8(2.0) 25.4(1.0) M12×1.75 12.6(0.50), 11.7(0.46)
2t~5t 101.6(4.0) 76.2(3.0) 25.4(1.0) M20×1.5 20(0.79)
7.5t,10t 175(8.89) 125(4.92) 50(1.97) M33×3 41(1.61), 39.5(1.56)
15t,20t 200(7.87) 160(6.3) 60(2.36) M42×3 51(2.01)
30t 230(9.06) 190(7.48) 80(3.15) M42×3 57(2.26)

 

Wiring:

◎Shielded, 4 conductor cable;

◎Cable diameter: Φ5mm;

◎Standard cable length for 25kg — 1.5t: 3m and for 2t — 30t: 6m;

◎Shield not connected to element;