LC476 5/10/20/50/100/200/300T Compression Column Type Load Cells

Dimension:

Technical Parameter:
케이센서스 스마트스토어

Dimension:

| Cap.(T) | Dia.A | Dia.B | Dia.C | D | E |
| 5t | 18 | 55 | 62 | 70 | 3 |
| 10t | 18 | 55 | 62 | 80 | 3 |
| 20t | 43 | 68 | 96 | 80 | 3 |
| 50t | 80 | 112 | 130 | 110 | 5 |
| 100t | 85 | 118 | 158 | 110 | 5 |
| 200t | 120 | 162 | 240 | 120 | 5 |
| 300t | 120 | 179 | 240 | 120 | 5 |
Technical Parameter:
| Rated Load: | 5/10/20/50/100/200/300t | Operating Temp. Range: | -30~+70℃ |
| Sensitivity: | (2.0±0.1%) m V/V | Max. Safe Over Load: | 150%F.S |
| Combined Error: | ±0.02% F.S | Ultimate Over Load: | 300%F.S |
| Creep Error(30min): | ±0.02% F.S | Recommend Excitation: | 10~12V DC |
| Zero Balance: | ±1% F.S | Maximum Excitation: | 15V DC |
| Temp. Effect On Zero: | ±0.02% F.S/10℃ | Sealing Class: | IP67/IP68 |
| Temp. Effect On Span: | ±0.02% F.S/10℃ | Element Material: | Alloy /Stainless Steel |
| Input Resistance: | 750±5Ω | Cable: | Length=L:13m |
| Output Resistance: | 702±2Ω | Citation: | GB/T7551-2008/ OIML R60 |
| Insulation Resistance: | ≥5000MΩ | Mode Of Connection: | Red(Input+),Green(Output+)
Black(Input-),White(Output-) |
| Product name | LC476 5/10/20/50/100/200/300T Compression Column Type Load Cells |
| Brand | SAINTBOND |
| Market | All over the world |
| Features | High precision and stable performance |
| Advantage | 0EM/ODM |
| Sample Lead Time | 5~ 40Days |
| Sample price | The price is different according to product capacity |
| Custom Design | Welcome |
| Form of sale | Factory supply |
| Model: | NF403 |
| Category: | Column Load Cells |
| Capacity: | 10,20,50,75,100,150kN |
| Rated Output: | 2.0±10%mV/V |
| Material: | Stainless steel |
Product description:
Capacity :0~200kg
Stainless steel
High stability
Can be installed in small spaces
Stable anti-interference signal
Compared with traditional column sensor, this structure achieve relatively high accuracy in terms of linearity, anti- side, torsional resistance, and azimuth error.
Product description:◆Capacity :0~200N ◆ Stainless steel ◆High stability ◆ Can be installed in small spaces ◆ Stable anti-interference signal ◆ Compared with traditional column sensor, this structure achieve relatively high accuracy in terms of linearity, anti- side, torsional resistance, and azimuth error. ◆Widely used in automotive pressing, automatic assembly, 3C product testing, new energy product assembly, medical testing, machines Robot field, mold assembly and other industrial testing,motorizing equipment and testing field
Widely used in auto press assembly, automated assembly, 3C product testing;
New energy product assembly, medical testing, robot, mold assembly and other industrial test, measurement and systems.
Material: stainless steel, Aluminum alloy
Size: Overload Protection High precision
| Product name | LC409MA Zemic Weighing Column Load Cell Digital Load Cell |
| Brand | SAINTBOND |
| Market | All over the world |
| Features | High precision and stable performance |
| Advantage | 0EM/ODM |
| Sample Lead Time | 5~ 40Days |
| Sample price | The price is different according to product capacity |
| Custom Design | Welcome |
| Form of sale | Factory supply |
| Model: | NF411 |
| Category: | Column Load Cells |
| Capacity: | 5,10,20,50,100kN |
| Rated Output: | 1.0±10%mV/V |
| Material: | Stainless steel |
| Protection Class: | IP66 |
With the characteristics of imple structure, high reliability and good interchangeability, the column type tension load cell is suitable for various proportioning scales, hopper scales, hook scales, etc.
Model 41 is a low profile “pancake” type load cells. These bonded foil, strain gage load cells are engineered to measure loads from 5 lb to 500,000 lb. The tension/ compression Model 41 is designed with the threaded hole running completely through the center of the cell. Model 41 utilizes two stabilizing diaphragms, which are welded to the sensing member to reduce off-center and side-loading effects. It provides high performance in non-linearity, hysteresis, and repeatability specifications for such applications as tube mills, extruding processes and weighing. Each unit has a welded construction and can be hermetically sealed for added durability. Model 41 load cells are available with optional 0 Vdc to 5 Vdc or 4 mA to 20 mA output.
| Model: | NF401 |
| Category: | Column Load Cells |
| Capacity: | 10,20,30,50N |
| Rated Output: | 2.0±10%mV/V |
| Material: | Stainless steel |