Категория: Метка: Бренд:

UTILCELL / R540S COMPRESSION TYPE LOAD CELL


Product description:

R540S is a large range capacity compression load cell, it is compact and low-profile, capacity is from 1t to 60t. It is widely suitable for applications in t heavy-duty process weighing industry, it is with smooth electro-polished surfaces so that it is easy to be cleaned, and is ideally suited to weighing applications in clean-in-place/sterilize-in-place environments. Full stainless steel constructure, completely hermetically sealed by laser. Also it is designed with separate mandrel with self-aligning arc point to receive force vertically to ensure the high force accuracy.

Main Features:

• Material: Stainless steel

• Rated Capacities: 1t~60t

• OIML R60, NTEP HB44, CE and RoHS certified

• IP Rating: IP68

• Suitable for process weighing of hopper scales, silo scales, tank scales.

• High precision by OIML R60 C3, high reliability.

Category: Compression


Share it:

R540S COMPRESSION TYPE LOAD CELL

Parameter Units Specification
Model No. R540S
Rated capacity (Emax) t 0.5t; 1t; 2t; 5t; 10t; 15t; 28t; 60t
Min. dead load kg 0
Rated output mV/V 2.0 ± 0.1%
Zero balance % of Emax ± 1
Combined error 1)2) % of Emax < ± 0.05
Repeatability error % of AL 3) < ± 0.02
Creep; 30 minute % of AL < ± 0.03
Min. dead load output return (DR); 30 min % of AL < ± 0.03
Temp. effect on Min. dead load output % of Emax/℃ < ± 0.002
Rated output 2) % of AL/℃ < ± 0.002
Temperature range Compensated ℃(°F) -10 to +40 [+14 to +104]
Operating -30 to +65 [-22 to +149]
Safe storage -40 to +80 [-40 to +176]
Excitation voltage Recommended V AC/DC 5 ~ 15
Maximum 20
Terminal resistance Excitation Ω 0.5t-5t: 1150 ± 10 10t-60t: 1530 ± 10
Output 0.5t-5t: 1050 ± 3 10t-60t: 1400 ± 3
Insulation resistance @50VDC >5000
Breakdown voltage V AC >500
Seal type / IP rating Hermetically welded / IP68
Load limit Safe % of Emax 150
Ultimate 300
Material Spring element Stainless steel
Cable Φ6; 4-wire; PVC
Cable length m 0.5t 1t … 15t 28t … 60t
3 6 12
Weight; approx kg 0.5t~5t 10t~15t 28t~60t
1.0 2.0 5.0
Fatigue life cycles @Emax >1,000,000
Deflection at Emax; approx mm <0.5
Notes:
1) Error due to the combined effect of non-linearity and hysteresis
2) The sum of errors due to Temperature Effect on Output comply with the requirements of OIML R60 and NIST HB44
3) AL = Applied Load