SP1320 SINGLE POINT LOAD CELL
| Parameter | Units | Specification | ||
| Model No. | SP1320 | |||
| Rated capacity (Emax) | kg | 300 / 500 / 750SE | 750 / 1000 / 2000 | |
| Accuracy class | C3 C6 | |||
| Min. dead load | kg | 0 | ||
| Rated output | mV/V | 2.0 ± 0.2 | ||
| Zero balance | % of Emax | ± 2 | ||
| Repeatability error | % of AL 3) | < ± 0.010 < ± 0.005 | ||
| Creep; 30 minute | % of AL | < ± 0.017 < ± 0.0083 | ||
| Min. dead load output return (DR); 30 min | % of AL | < ± 0.017 < ± 0.0083 | ||
| Temp. effect on | Min. dead load output | % of Emax/℃ | < ± 0.0020 < ± 0.0014 | |
| Rated output 2) | % of AL/℃ | < ± 0.0012 < ± 0.0006 | ||
| Temperature range | Compensated | ℃(°F) | -10 to +40 [+14 to +104] | |
| Operating | -10 to +50 [+40 to +122] | |||
| Safe storage | -30 to +70 [-22 to +158] | |||
| Excitation voltage | Recommended | V AC/DC | 5 ~ 15 | |
| Maximum | 15 | |||
| Terminal resistance | Excitation | Ω | 404 ± 10 | |
| Output | 350 ± 3 | |||
| Insulation resistance @50VDC | MΩ | >5000 | ||
| Breakdown voltage | V AC | >500 | ||
| Seal type / IP rating | potted silicon sealed / IP66 | |||
| Load limit | Safe | % of Emax | 150 | |
| Ultimate | 300 | |||
| Material | Spring element | Aluminum, anodizing | ||
| Cable | Φ6; 4-wire; PVC | |||
| Cable length | m | 3.0 | ||
| Maximum platform size | mm | 600*800 | 1200*1200 | |
| Offer center load error (OIML R76) | % of AL/cm | < ± 0.0016 | ||
| Fatigue life | cycles @Emax | >1,000,000 | ||
| Deflection at Emax; approx | mm | <0.5 | ||
| Weight; approx | kg | 1.8 | 3.6 | |
| Barometric pressure effect on Zero Output | Vmin/kPa | <1.0 | ||
| Mounting screw | Size/Grade | M12-10.9 | M16-10.9 | |
| Recommended torque | N.m | 98.0 | 160.0 | |
| Notes: | ||||
| 1) Error due to the combined effect of non-linearity and hysteresis | ||||
| 2) The sum of errors due to Temperature Effect on Output comply with the requirements of OIML R60 and NIST HB44 | ||||
| 3) AL = Applied Load | ||||