UTILCELL / SL5126 / Single Point Load Cell



Share it:

SL5126 Bench Scale Single Point Load Cell

Product Features

Multi-axis force sensor is a kind of force sensor which can measure the force and torque components in more than two directions simultaneously. Multi — axis force sensors are divided into two — axis force sensors, three — axis force sensors and six — axis force sensors. The three-axis force sensor can simultaneously detect the change of force value in three directions, X axis, Y axis, Z axis (vertical force), and output three groups of voltage signals.

Three-dimensional force sensor, high-speed sampling, high-speed dynamic response, anti-interference, long-term stable performance, sensitive response;
And it is small in size and light in weight, can measure spatial acceleration, and can fully and accurately reflect the motion properties of objects.

Technical Specifications

Specfications Technique
Maximum capacity (Emax) 50/60/80/100/150/200/250/300/400/500kg
Output sensitivity (=FS) 2.0±0.2mV/V
Accuracy class C3 C4 C5
Combined error ±0.02%FS Emax/15000 Vmin OIML R60 C4
Creep ±0.0167%FS/30min ≤ ±0.018%FS OIML R60 C4
Temperature effect on sensitivity ±0.0175%FS/10℃ ≤ ±0.012%FS/30min OIML R60 C4
Temperature effect on zero ±0.02%FS/10℃ ≤ ±0.009%FS/10℃ OIML R60 C4
Zero balance ±2%FS
Compensated temperature -10~40℃
Operating temperature -35~65℃
Input resistance 406±6Ω
Output resistance 350±3Ω
Insulation resistance ≥5000MΩ(50VDC)
Excitation, recommended voltage 5~12VDC
Excitation maximum 18VDC
Safe overload 120%FS
Ultimate overloadProtection  150%FS
Class  IP65
Cable specification φ5.3mm
Cable length 2m
Recommended scale size 400x400mm
Corner correction 0.02% load value/100mm
Recommended torque on fixation 20N.m
Wiring Red: Input+, Green: Output+, Transparent: Shield,Black: Input-,White: Output-

Product Dimensions

Installation size

SL5126-1.JPG

Load Direction

Wiring Diagram

Accurate measurement with matching display

The output of the force measuring and weighing sensor itself is an MV signal, which needs to be amplified and convertedto display numerical values or output signals to the upper computer, PLC, etc.