GSS416 Through hole donut load cell
What is specifications of GSS416 Load cell?
| Specifications: | |||
| Range | 120, 180, 220,260,330, 400KN | Input resistance | 735±35Ω |
| Sensitivity | 1.5±0.1mV/V | Output resistance | 700±3Ω |
| Comprehensive error (%F.S) | 0.1%F.S | Insulation resistance | ≥2000MΩ |
| Creep | ±0.1%F.S/30min | Excitation voltage | 5~12VDC |
| Non-linearity | ±0.05%F.S | Operation temp. range | -20~+70℃ |
| Hysteresis | ±0.05%F.S | Ultimate overload | 120%F.S |
| Repeatability | ±0.05%F.S | Ingress protection | IP66 |
| Temp.effect on zero | ±0.03%F.S/10℃ | Material | Alloy steel |
| Temp.effect on span | ±0.03%F.S/10℃ | Cable | Φ5*2000mm |
What is dimension of GSS416 Load cell?

|
Range (KN) |
A |
B |
C |
|
120 |
47.4 |
31 |
17 |
|
180 |
58.4 |
38 |
22 |
|
220 |
62.4 |
42 |
24 |
|
260 |
66.4 |
44 |
26 |
|
330 |
72.4 |
51 |
29 |
|
400 |
74.4 |
53 |
32 |