ZHIMIN / ZM300 / Светодиодный весовой индикатор с 6-разрядным дисплеем, питание 220 В


The display uses a 24 bit A / D converter, can be connected to various types of sensors and transmitters to achieve the pressure, flow, level, composition analysis and volume measurements, and other physical and mechanical parameters, display, alarm monitoring, data acquisition and recording.

Functions:
Relay(1,2,3)
Amplifer 4-20mA, 0-5V
Modbus RTU RS485
Dual 6 digit LED display

Baud rate 19200

Applications:
Load cells
Torque transducers

Share it:

ZM300 220V LED 6 digit weight indicator

1.Introduction:

The display uses a 24 bit A / D converter, can be connected to various types of sensors and transmitters to achieve the pressure, flow, level, composition analysis and volume measurements, and other physical and mechanical parameters, display, alarm monitoring, data acquisition and recording.

2.Parameters:

Work Environment: Temperature-20-50℃ Display Dual 5 high brightness red LED
Humidity:20-90%RH Output excitation voltage 5V ~15V (for sensor supply), current <50MA
Accuracy ±0.2%F.S±1 word Supply Voltage AC195 ~ 242V, power consumption <5w
Monitoring cycle 0.2 seconds: can be increased to 0.05 seconds

3.Button introduction

“SET”button:SET “>”button:Shift key or tare key(peak meter)

“∧”button:UP “CLR”button:Peak clear key or tare key(upper and lower limit gauge)

  1. Content:
Symbol Name Range
SAL OUT1relay 00000~full scale
SPL OUT1deviation 0<SPL<SAL
SAH OUT2relay 00000~full scale
SPH OUT2deviation 0<SPH<SAL
SL Zero calibration 00000
SH Load calibration More than half scale
Sd Decimal location 0~3
Id Division value 1.2.5.10.20
CLTF Peel key selection 0.1
FIL Weight filtering degree 1-9
ZERO Zero tracking range 0~4
bd Baud rate 0~3
Ad Address setting(RS485 only) 01-30
OUTF Alarming output 0 or 1
  1. Operating introduction:

1. Press’SET’ more than three seconds to show ‘SAL’for setting OUT1relay. Press’SET’ again to show ‘SPL’ for setting OUT1deivation Explanation: When ‘SPL’=0, if force value > SAL, OUT1 close; If force value < SAL, OUT release When ‘SPL’≠0, if force value > SAL+SPL, OUT1 close; If force value < SAL+SPL, OUT1 release

2. Press’SET’ to show ‘SAH’for setting OUT1relay. Press’SET’ again to show ‘SPH’ for setting OUT2deivation

3. PressSET to show CIN for entering password. The original password is 00000. If you don t want to change password, press SET for next step. If you want to change password, press CLR to show CON, set your 5 digit password and press SET for next step.

4. Press ‘ SET’ to show ‘SL’ for zero calibration

5. Press’SET ’to show ‘SH’ for load calibration. The loading should be more than half scale. Input corresponding force value.

6. Press’SET’ to show ‘Sd’ for decimal setting. Press ‘∧’ for adjusting decimal location.

7. Press’SET’ to show ‘Id’ for division value.

8. Press’SET’ to show ‘CLFT’ for peel key selection. When ‘CLFT’ is 0, ‘CLR’ can peel. When ‘CLFT’ is 1, ‘CLR’ cann’t peel.

9. Press ‘SET’ to show ‘FIL’ for weight filtering. The value is from 1-9. The value means the speed of value stability. The bigger the value is, the slower the speed stabilize.

10. Press ‘SET’ to show ‘ZERO’, if the time is less than 2 seconds, the value will track to zero.

  1. Communication protocol
  2. Baud rate
bd Value Baud rate
0 2400
1 4800
2 9600
3 19200
  1. RS232 wiring definition

Serial ports are GND(indicator 21 foot), RXD(indicator 22 foot), TXD(indicator 23 foot), RXD refers to PC’s RXD. TXD refers to PC’s TXD.

  1. Communication adopts MODBUS-RTU format: address domain+functional domain+data domain+check domain

Functional domain:

Functional code meaning Behavior
0x03 Read data register Read data register value
0x10 Modify data register Overwrite multi-bit data register values

Format:

Read data register

address function Data

start reg hi

Data

start reg lo

Data # of

Reg hi

Data # of

Reg lo

Crc-16 lo Crc-16 hi
0x01 0x03 0x00 0x55 0x00 0x01 0x94 0x1A

Modify the switch

address function Data

start reg hi

Data

start reg lo

Data # of

Reg hi

Data # of

Reg lo

Crc-16 lo Crc-16 hi
0x01 0x05 0x00 0x00 0xFF 0x00 CRC0 CRC1

Modify data register

address function Data

start reg hi

Data

start reg lo

Data # of

Reg hi

Data # of

Reg lo

Byte

count

Value hi Value

lo

Crc-16 lo Crc-16 hi
0x01 0x10 0x00 0x50 0x00 0x01 0x02 0x03 0xE8 0xAA 0xBE

Address: Follower address function: function code

Data start reg hi: Register start address high byte Data start reg lo: Register start address low byte

Data # 0f reg hi: Read register number high byte Data # 0f reg lo: Read register number low byte

Crc -16 lo: Check code low byte Crc -16 hi: Check code high byte

  1. Parameters and address

Register addressParametersValue rangeData type 0x50LO limit0-60000word 0x51LO deviation0-60000word 0x52UPPER limit0-60000word 0x53UPPER deviation0-60000word 0x54Decimal0-3word 0x55Positive or negative0 is positive ; 1 is negativeword 0x56Value display0-60000word0x57peelWrite 1 means peelword

  1. Attention

1. Setting error or invalid, press’∧’ for reset.

Press’>’ for three seconds to display 0 or 1. Press ‘>’ again for switching 0 and 1. When display ‘0’ press’>’ for lowest force value indicator, when display ‘1’ for peak indicator.