| Product Performance | |
|---|---|
| Long-Term Stability | |
| Pressure | ±1%FS/year (Not cumulative) |
| Temperature | ±0.5%FS, 0.1℃/year (The larger value applies) |
| Accuracy | |
| Accuracy | ±1%FS |
| Temperature Effect | |
| Pressure | 1.5%FS / 100℃ |
| Temperature | ≤ ±0.5%FS/℃ (Reference: 22℃) |
| Temperature Range | |
| Compensation Temp. | -20℃ ~ 60℃ (Pressure) |
| Working Temp. | -30℃ ~ 70℃ |
| Errors | |
| Zero Error | ±2%FS (Pressure) |
| Span Error | ±2%FS (Pressure) |
| Response Time | |
| Pressure | ≤10 ms |
| Temperature | t09 = 10 sec |
| Physical Characteristics | |
| Fatigue Life | More than 100 million cycles |
| Pressure Interface | See Ordering Guide |
| Protection Tube Diameter | 6 mm, 8 mm, etc. |
| Electrical Interface | See Ordering Guide |
| Shell Protection | IP65 |
| Shock | EC 68-2-32, Procedure I |
| Vibration | 40 g, 20–2000 Hz |
| Weight | About 250 g |
| Environmental Data | |
| Certification | CE, RoHS |
| Voltage Output | |
| Output (3-wire) | Min 0V to Max 10V |
| Power Supply | Over full range output 4V, Max 30 VDC |
| Current Output | |
| Output (2-wire) | 4–20 mA, 4–20 mA + HART (2-wire) |
| Power Supply | 10–30 VDC |

It is used in the process control fields of power and coal industries such as boiler air supply and underground ventilation.
Model: X-100CY-Q-①②③④⑤
| ① | ② | ③ | ④ | ⑤ | |
| Attention | Range | Process connection | Output | Electrical connection | Accuracy |
| 1. Direct lead with 1 m cable
2. With”*”,please contact thetechnician |
Range
K=kPa B=bar M=MPa |
6=Φ6mm
Pagoda mouth 8=Φ8mm Pagoda mouth XX*=Other* |
4A=4~20mA
4AX= 4-20mA+LCD With Display 10V=0~10V |
xE= Direct lead x meter | =±0.5
%FS 2=±0.25 %FS |