Xjcsensor / X-100CY-Q Wind Differential Pressure / Pressure Sensor/Pressure Transmitter


Feature
  • Range: 0-1kpa-600kpa.
  • High performance core, Compact design.
  • Multiple output signals optional.
  • Field adjustable calibration.
  • Superior long term stability.

Share it:
Technical Parameter
Product Performance
Long-Term Stability
Pressure ±1%FS/year (Not cumulative)
Temperature ±0.5%FS, 0.1℃/year (The larger value applies)
Accuracy
Accuracy ±1%FS
Temperature Effect
Pressure 1.5%FS / 100℃
Temperature ≤ ±0.5%FS/℃ (Reference: 22℃)
Temperature Range
Compensation Temp. -20℃ ~ 60℃ (Pressure)
Working Temp. -30℃ ~ 70℃
Errors
Zero Error ±2%FS (Pressure)
Span Error ±2%FS (Pressure)
Response Time
Pressure ≤10 ms
Temperature t09 = 10 sec
Physical Characteristics
Fatigue Life More than 100 million cycles
Pressure Interface See Ordering Guide
Protection Tube Diameter 6 mm, 8 mm, etc.
Electrical Interface See Ordering Guide
Shell Protection IP65
Shock EC 68-2-32, Procedure I
Vibration 40 g, 20–2000 Hz
Weight About 250 g
Environmental Data
Certification CE, RoHS
Voltage Output
Output (3-wire) Min 0V to Max 10V
Power Supply Over full range output 4V, Max 30 VDC
Current Output
Output (2-wire) 4–20 mA, 4–20 mA + HART (2-wire)
Power Supply 10–30 VDC
Dimension & Capacity

pic-1

Application

It is used in the process control fields of power and coal industries such as boiler air supply and underground ventilation.

Ordering Guide

Model: X-100CY-Q-①②③④⑤

Attention Range Process connection Output Electrical connection Accuracy
1. Direct lead with 1 m cable

2. With”*”,please contact thetechnician

Range

K=kPa

B=bar

M=MPa

6=Φ6mm

Pagoda mouth

8=Φ8mm

Pagoda mouth

XX*=Other*

4A=4~20mA

4AX= 4-20mA+LCD

With Display

10V=0~10V

xE= Direct lead x meter =±0.5

%FS

2=±0.25

%FS

File Download