VALCOM / VZ6FC6 Extremely High Accurate Beam Load Cell


  • 50kg–200kg
  • Ultrahigh accuracy, Non Linearity: 0.0110%R.C.
  • Particularly good environmental resistance

Share it:

VZ6FC6 Extremely High Accurate Beam Load Cell

Specifications

Rated output 2mV/V±0.05%
Nonlinearity ±0.0110%R.C.
Hysteresis ±0.0080%R.C.
Zero balance −0.020–0.020mV/V
Temperature effect on zero balance ±0.0093%R.C./10°C
Temperature effect on load ±0.0040%R.C./10°C
Safe overload rating 150%R.C.
Temperature compensation range −10–40°C (No condensation or freezing)
Safe temperature range −30–70°C (No condensation or freezing)
Input terminal resistance 350.0–480.0Ω
Output terminal resistance 356±0.12Ω
Recommended excitation voltage 5V
Excitation voltage range 0.5–12V
Insulation resistance 5000MΩ
IP rating Equivalent to IP68 (Note 1)
Cable φ5.4mm 6-core Shielded cable 3m
  • Creep 30min:±0.083%R.C.
  • (Note 1) Sealing performance of the cable outlet may deteriorate due to the change of cable jacket over years.

Model selection

Selection Model Rated capacity Deflection at R.C. Weight
VZ6FC6-50kg 50kg (490.3N) Approx. 0.27mm Approx. 0.5kg
VZ6FC6-100kg 100kg (980.7N) Approx. 0.31mm
VZ6FC6-200kg 200kg (1.961kN) Approx. 0.39mm
  • *Weight includes cable.

External dimensions (Unit: mm)