SP1041 SINGLE-POINT LOAD CELL
| Parameter | Units | Specification | |
| Model No. | SP1041 | ||
| Rated capacity (Emax) | kg | 10 / 20 / 30 / 50 / 100 | |
| Accuracy class | C3 C6 | ||
| Min. dead load | kg | 0 | |
| Rated output | mV/V | 2.0 ± 0.2 | |
| Zero balance | % of Emax | ± 2 | |
| Repeatability error | % of AL 3) | < ± 0.010 < ± 0.005 | |
| Creep; 30 minute | % of AL | < ± 0.017 < ± 0.0083 | |
| Min. dead load output return (DR); 30 min | % of AL | < ± 0.017 < ± 0.0083 | |
| Temp. effect on | Min. dead load output | % of Emax/℃ | < ± 0.0020 < ± 0.0014 |
| Rated output 2) | % of AL/℃ | < ± 0.0012 < ± 0.0006 | |
| Temperature range | Compensated | ℃(°F) | -10 to +40 [+14 to +104] |
| Operating | -10 to +50 [+14 to +122] | ||
| Safe storage | -30 to +70 [-22 to +158] | ||
| Excitation voltage | Recommended | V AC/DC | 5 ~ 15 |
| Maximum | 15 | ||
| Terminal resistance | Excitation | Ω | 403 ± 10 |
| Output | 350 ± 3 | ||
| Insulation resistance @50VDC | MΩ | >5000 | |
| Breakdown voltage | V AC | >500 | |
| Seal type / IP rating | potted silicon sealed / IP66 | ||
| Load limit | Safe | % of Emax | 150 |
| Ultimate | 300 | ||
| Material | Spring element | Aluminum, anodizing | |
| Cable | Φ5.6; 4-wire; PVC | ||
| Cable length | m | 2.0 | |
| Maximum platform size | mm | 400*400 | |
| Offer center load error (OIML R76) | % of AL/cm | < ± 0.0028 | |
| Fatigue life | cycles@Emax | >1,000,000 | |
| Deflection at Emax; approx | mm | <0.5 | |
| Weight; approx | kg | 0.4 | |
| Barometric pressure effect on Zero Output | Vmin/kPa | <1.0 | |
| Mounting screw | Size/Grade | M6 / 8.8 | |
| Recommended torque | N.m | <50kg: 10; ≥50kg: 15 | |
| Notes: | |||
| 1) Error due to the combined effect of non-linearity and hysteresis | |||
| 2) The sum of errors due to Temperature Effect on Output comply with the requirements of OIML R60 and NIST HB44 | |||
| 3) AL = Applied Load | |||