B530S SINGLE ENDED BEAM LOAD CELL
| Patameter | Units | Specifications | ||||||
| Model No. | B530S/B730S | |||||||
| Rated capacity (Emax) | t | 0.5;1 | 2 | 3 | 5 | |||
| Accruacy class 1)2) | C3 C5 | |||||||
| Min. dead load | kg | 0 | ||||||
| Rated output | mV/V | 2.0 ± 0.002 | ||||||
| Zero balance | % of Emax | ± 1 | ||||||
| Repeatability error | % of AL 3) | < ± 0.010 < ± 0.006 | ||||||
| Creep; 30 minute | % of AL | < ± 0.017 < ± 0.010 | ||||||
| Min. dead load output return (DR); 30 min | % of AL | < ± 0.017 < ± 0.010 | ||||||
| Temp. effect on | Min. dead load output | % of Emax/℃ | < ± 0.0020 < ± 0.0014 | |||||
| Rated output 2) | % of AL/℃ | < ± 0.0012 < ± 0.0007 | ||||||
| Temperature range | Compensated | ℃(°F) | -10 to +40 [+14 to +104] | |||||
| Operating | -40 to +65 [-40 to +149] | |||||||
| Safe storage | -40 to +80 [-40 to +176] | |||||||
| Excitation voltage | Recommended | V AC/DC | 5 ~ 15 | |||||
| Maximum | 15 | |||||||
| Terminal resistance | Excitation | Ω | 384 ± 5 | |||||
| Output | 350 ± 3 | |||||||
| Insulation resistance @50VDC | MΩ | >5000 | ||||||
| Breakdown voltage | V AC | >500 | ||||||
| Seal type / IP rating | Hermetically welded / IP68 IP69k | |||||||
| Load limit | Safe | % of Emax | 150 | |||||
| Ultimate | 300 | |||||||
| Material | Spring element | Stainless steel [ B730S: 17-4PH ] | ||||||
| Strain gauge | PEEK [ B730S: HBK SG ] | |||||||
| Cable | Φ5.4; 4-wire; PVC | |||||||
| Cable length | m | 5.0 | ||||||
| Weight; approx | kg | 0.5;1t | 2t | 3t | 5t | |||
| 1.0 | 1.4 | 1.8 | 4.0 | |||||
| Fatigue life | cycles @Emax | >1,000,000 | ||||||
| Deflection at Emax; approx | mm | <0.5 | ||||||
| Barometric pressure effect on Zero Output | Vmin/kPa | <1.0 | ||||||
| Mounting screw | Size/Grade | M12 / A2-70 | M12 / A2-70 | M14 / A2-70 | M18 / A2-70 | |||
| Recommended torque | N.m | 98 | 120 | 140 | 275 | |||
| Notes: | ||||||||
| 1) Error due to the combined effect of non-linearity and hysteresis | ||||||||
| 2) The sum of errors due to Temperature Effect on Output comply with the requirements of OIML R60 and NIST HB44 | ||||||||
| 3) AL = Applied Load | ||||||||