GT16XX Fluid Pressure Sensor
Technical parameters
| Parameter | Value / Description |
|---|---|
| Standard pressure ranges | 0–50, 75, 100, 200, 500, 750, 1000, 1500, 2000, 3000, 5000, 7500, 10,000, 15,000, 20,000, 25,000, 30,000, 40,000 psi (PSIA or PSIG) |
| Static accuracy | ±0.1% FSO |
| Resolution | Analog: essentially infinite; Digital: 0.025% FSO |
| Insulation resistance | >100 MΩ (50 VDC, 21 °C) |
| Zero shift | < ±0.005% FSO/°F (standard) |
| Span shift | < ±0.005% FSO/°F (standard) |
| Proof pressure | 150% of rated range |
| Burst pressure | 200% of rated range |
| Wetted materials / media | 17‑4 stainless steel for compatible liquids and gases, with BUNA‑N and Krytox oil; optional nickel‑chromium alloy |
| Pressure ports (50–10,000 psi) | 1/4″ NPT female (standard); 1/4″ NPT male (no‑charge option) |
| Pressure ports (15,000–40,000 psi) | AE F250‑C, 9/16″‑18 UNF or equivalent (standard) |
| Secondary containment | 4500 psi (standard); 10,000 psi (optional) |
| Weight | 454 g |
| Analog current output | 4–20 mA |
| Isolated voltage output | 0–5 VDC, 0–10 VDC |
| Non‑isolated voltage output | 0–5 VDC, 1–5 VDC, 1–6 VDC |
| Digital outputs | RS‑232, RS‑485, CAN |
| Output isolation resistance | >100 MΩ (50 V, 70 °F) |
| Electrical connector | PTIH‑10‑6P stainless‑steel weldable connector or equivalent |
| Electrical protection | EMI protection; surge/over‑voltage protection to 2500 V; output short‑circuit protection |
| Compensated temperature range | –35 to 76 °C |
| Operating temperature range | –54 to 121 °C |
Dimensions