DT14XX-Fluid Pressure Sensor
Technical parameters
| Parameter | Value / Description |
|---|---|
| Standard ranges | 0–1, 2, 5, 10, 15, 20, 25, 30, 50, 75, 100, 150, 200, 250, 300, 400, 500 PSID |
| Linearity | ±0.25% FSO |
| Hysteresis | ±0.25% FSO |
| Repeatability | ±0.20% FSO |
| Zero shift vs. temperature | < ±0.010% FSO/°F |
| Weight | 2 kg |
| Analog current output | 4–20 mA |
| Analog voltage output (isolated) | 0–5 VDC, 0–10 VDC |
| Analog voltage output (non‑isolated) | 0–5 VDC, 1–5 VDC, 1–6 VDC |
| Digital outputs / supply | RS‑232, RS‑485, CANBUS; operates from 8–30 VDC |
| Output insulation resistance | >100 MΩ (50 VDC, 21 °C) |
| Wetted materials / media | 316 stainless steel for compatible liquids and gases with BUNA‑N and Krytox oil; optional Hastelloy‑wetted parts and O‑ring materials |
| Pressure ports | 7/16″‑20 per AS5202E4 / MS33649‑4 female (standard); 1/4″ NPT female (no‑charge option); 7/16″‑20 per AS4395E4 / MS33656‑4 male (optional); 1/4″ NPT male (optional) |
| Electrical protection | EMI protection; surge protection to 500 VDC; output short‑circuit protection |
| Electrical connection | PTIH‑10‑6P stainless‑steel connector or equivalent electrical termination |
| Compensated temperature range | –23 to 71 °C |
| Operating temperature range | –40 to 85 °C |
Dimensions