KR80 Column Force Sensor
Technical
| Mechanical Characteristics | ||
|---|---|---|
| Range | t | 0.25,05,1,2,3.5,5,10 |
| Calibration method | Pressure | |
| Material | Stainless steel1.4542 | |
| Deflection | mm | 0.1 ± 0.02 |
| Safe overload | % FS | 150 |
| Breaking overload | % FS | 300 |
| Maximum measuring load | % FS | 100 |
| Electrical Characteristics | ||
| Sensitivity | mV/V | 2.0±0.1(1.75 ±0.1for0.25t) |
| Excitation voltage—MAX | V | 18 |
| Input resistance | Ohm | 1110 ±50 |
| Output resistance | Ohm | 1025±25 |
| Insulation resistance | Ohm | > 5×109 |
| Cable length | m | 3 (5 from 2t) |
| Accuracy Data | ||
| Accuracy class (OIML R60 standard) | C3 | |
| Maximum number of divisions | 3000 | |
| Minimum number of divisions | FS / 10000 | |
| Combined error | % SN | < ±0.023 |
| Zero output | % FN | < ±0.025 |
| Creep within 30 minutes | % SN | < ±0.0245 |
| Zero temperature drift | % FN / 5°C | < ±0.007 |
| Sensitivity temperature drift | % SN / 5°C | < ±0.005 |
| Temperature | ||
| Operating temperature range | °C | -10…+40 |
| Service temperature range | °C | -30…+70 |
Dimensions