MLC116 high temperature load cell for ladle scale weighing



| Other sizes | ||||||||||||||||||
| Rang
e |
A | B | C | D | E | F | G | H | J | K | L | M | N | P | Q | R | S | T |
| 50t | 450 | 120 | 130 | 105 | D38 | 398 | 68 | 75 | 40 | 80 | 110 | D26 | M20/30 | 32 | 45 | 340 | 25.5 | 57 |
| 100t | 500 | 140 | 143 | 118 | D44 | 444 | 80 | 90 | 44 | 90 | 130 | D30 | M24/36 | 38 | 54 | 370 | 28.5 | 62 |
| 150t | 560 | 160 | 158 | 133 | D48 | 500 | 94 | 102 | 44 | 90 | 150 | D33 | M24/36 | 38 | 66 | 410 | 32 | 69 |
| 200t | 620 | 180 | 175 | 150 | D48 | 560 | 114 | 110 | 44 | 90 | 160 | D33 | M24/40 | 40 | 75 | 450 | 32 | 76 |
| Technical specifications | |||
| Comprehensive error | 0.1%FS | Output resistance | 702±5Ω |
| Rated output | 2±0.005 mv/v | Insulation resistance | ≥5000MΩ(100VDC) |
| Nonlinear | 0.05%FS | Operating voltage | 9~12VDC |
| Hysteresis | 0.05%FS | Compensation temperature | -10~+40℃ |
| Repeatability | 0.03%FS | Operating temperature | -20~+ 70 ℃ / -20c~250c. |
| Creep | 0.03%FS/10MIN | Effect of Temp. on zero point: | 0.05%FS/10℃ |
| Zero output | ±1%FS | Effect of Temp. on sensitivity: | 0.05%FS/10℃ |
| Input resistance | 750±10Ω | Protection level | IP66 & IP68 |