카테고리: 태그: 브랜드:

Detail Sensing / DLC401 Column Type Load Cell


Rated Capacity: 3kg, 5kg, 6kg, 10kg, 15kg, 20kg, 30kg, 40kg, 50kg, 100kg

Size: 88*30*22 mm


Share it:

DLC401 Column Type Load Cell

Description of column style load cell

Model: DLC401

Category: column load cell

Range: 10t 25t 40t 60t 100t

Material: Alloy steel

Features: The sensor elastomer is made of alloy steel; it can provide welded seals; high precision and high reliability.

Application: Widely used in various weighing and measuring equipment such as electronic platform scales, truck scales and floor scales.

 

 Installation dimension specification (unit: mm):

DLC410.jpg

_20200304143838.png

Force diagram:

1545709638999009518.jpg

 

Detailed specifications of conventional sensor specifications:

 

Range (t): 10, 25, 40, 60, 100

Accuracy level : C3

Sensitivity temperature effect (%F.S/10°C): ±0.017

Comprehensive error (%F.S) : ±0.02

Zero temperature effect (%F.S/10°C) ±0.023

Sensitivity (mv/v) : 2.0±0.003

Temperature compensation range (°C ) : -10~+40

Creep (%F.S/30min) : ±0.024

Use temperature effect (°C ) : -20~+55

Zero output (%F.S) : ±1.0

Excitation voltage (V) : 9~12(DC)

Input impedance (Ω) : 450±5

Safety overload range (%F.S) : 150

Output impedance (Ω) 480±5

Extreme overload range (%F.S) : 200

Insulation resistance (MΩ) : ≥5000(100VDC)

Protection level; IP67; IP68

 

 

Detailed description of digital sensor technical indicators:

 

Range (t): 10, 25, 40, 60, 100

Accuracy level : C3

Digital module resolution (code) : 1,000,000

Comprehensive error (%F.S) : ±0.02

Communication Baud Rate (BPS) : 9600

Rated output (counts) : 1,000,000

Communication interface (cable) : RS 485/RS232

Creep (%F.S/30min) : ±0.02

Data refresh frequency (s) : 10~80

Sensitivity temperature effect (%F.S/10°C): ±0.011

Maximum verification scale value (n max) : 5000

Zero temperature effect (%F.S/10°C) : ±0.019

Maximum transmission distance (m) : 1200

Temperature compensation range (°C ) : -10~+40

Bus address number (max) : 32

Use temperature effect (°C ) : -20~+55

Safety overload range (%F.S) : 150

Excitation voltage (V) : 5.5~12(DC)

Protection level : IP67 / IP68

 

 

Digital sensor wiring method:

_20200304113905.png

Red line: Incentive ( +) 111 Green line: Signal ( +)
Black line: Incentive ( -) 111 White line: Signal ( -)

Remarks: Four-core shielded cable is used. The standard cable length is 10 meters. If you have special needs, you can provide it according to customer requirements!