CALT / CAS60 / 병렬 출력 싱글턴 앱솔루트 엔코더


  • Single-turn absolute encoder
  • Detection method: magnetoelectric encoder, Hall principle
  • Operating voltage: 10…30Vdc polarity protected
  • Output signal: Parallel output (pure binary, Gray code or Gray remainder)
  • Programmable, intelligent absolute encoder, professional setting software, user-friendly operation
    With setting line, easy to install and debug
  • Resolution: ≤12 bits, up to 4096 lines (order option)
  • Outer diameter 60mm, inner hole/shaft diameter 6-15mm optional
  • Protection class: shell IP67 shaft IP65
  • Vibration and shock: 20g, 10~2000Hz; 100g, 6ms
  • Allowable speed: 6000 rpm
  • Software and hardware can be customized according to actual needs

Share it:

Specifications

Mechanical parameters Electrical parameters
maximum speed 6000 rpm Operating Voltage 10-30Vdc (5Vdc can be customized)
Spindle load Axial 40N, Radial 100N current consumption < 300mA (24Vdc) no load
impact resistance 1000m/s²(6ms), equal to 100g output signal 12-bit synchronous parallel signal (pure binary, Gray code or Gray remainder)
Anti-vibration 200m/s²(10-2000Hz), equal to 20g Linear resolution 1/4096FS, 1/360FS or 1/720FS
Allow axial play ±1.5mm IP Class IP65 or IP68
Allow radial runout ±0.2mm Repeatability <2Bit
external structure 60mm OD, solid shaft, blind hole shaft Operating temperature -40℃~85℃
Connection Type 30 core shielded cable or aviation plug Storage temperature -40℃~85℃
reliable and patented

l Strong bearing structure with Safety-Lock TM design, which can provide higher vibration resistance and installation error resistance

l IP68 protection grade and wide operating temperature range -40℃…+85℃

l Patented mechanical gear technology, with permanent power-off memory function

performance optimization

l High precision, data refresh rate of location data ≤ 4us

l Direct reading through I/O port

l International standard SSI signal format

Wiring diagram

Black 20 Brown 28 Note:

1. For normal use, please short the two wires together

2. Forward and reverse: When connected to 24V+, the counterclockwise data increases

3. Set: connect to 24V + 1 second to set the current value to zero

4. Parallel output maximum 50mA per bit

 

White 21 Orange(white) 29
Green 22 Green(White) 210
Pink 23 Brown(White) 211
Orange 24 Ash Set   Note3
Purple 25 Red 10-30Vdc
Yellow 26 blue/Ash GND 0V  Note1
Ash(white) 27 Blue(White) Forward and reverse Note 2

Mechanical dimension drawing

Clamping synchro flange (optional for cable output or plug output)

Synchronous flange/servo flange (cable output or plug output optional)

Blind Hole/Half Through Hole Flange (Cable output or plug output optional)

output signal
The output is a parallel push-pull output signal, which is connected to the input module (I/O) of the PLC as shown in the figure below: