카테고리: 태그: , , 브랜드:

BRG SENSOR / KPC Analog Linear Position Sensor


Q: How long is your delivery time? A: Generally it is 2-4 days after full payment if the goods are in stock. or it is 7-12 days if the goods are not in stock, it is according to quantity. Q: What is your terms of payment ? A: We accept T/T, Paypal, Western union or money gramm. Q: What’s your warranty ? A: 12 months. If the items you purchased from our company are not with perfect quality or can’t work normally, you can ship back for replacement or refund.


Share it:

KPC Analog Linear Position Sensor

Description

Products :

The KPC articulated linear displacement sensor features an articulated mounting mechanism with fixed ends. Powered by 5V or 10V, it outputs 0-5V or 0-10V. Powered by 12V/24V, it can output 0-5V, 0-10V, 4-20mA, 0-20mA, and 1-20mA. RS485 and RS232 transmitter modules are required. It is suitable for position monitoring of large mechanical travel and back-and-forth motion, with no requirements for alignment. It is suitable for applications with no alignment requirements and motion, such as robots, unloaders, brick and shoe machines, ceramic machinery, geological hazards, sluice gates, 3D cinema seats, and entertainment equipment.

KPC-4

 

 

KPC-6

Expansion Joint Width Monitoring

 

To meet underground utility corridor design requirements, expansion joints are installed at regular intervals. Monitoring their width is critical to prevent issues like water seepage. Surface crack meters can be mounted directly on joints to track long-term opening and closing, even in harsh environments. Their universal joints allow limited shear displacement, while built-in temperature sensors record ambient conditions. With optional accessories, they can also function as void meters or bi-/tri-directional crack meters to measure void volume, joint displacement, or perimeter movement.

 

 

Features :

◇ Displacement range 50-750mm
◇ High resolution and immune to external signal interference
◇ Displacement speed 10m/s
◇ Output: Voltage divider ② RS485 ③ RS232
④ Voltage signal: DC24V output 0-5V/0-10V
⑤ Current signal: DC24V output 4-20mA
◇ Connector
KPC: Aviation plug with 1m shielded cable
KPC-F: Waterproof plug
◇ Service life >100 x 106 cycles under different conditions

KPC-7

 

 

 

Technical parameter

 

KPC mm 50 100 130 150 175 200 225 275 300 375 400 450 500 600 750
Actual range(A.E) mm 50 100 130 150 175 200 225 275 300 375 400 450 500 600 750
Theoretical Range(T.E) mm AE+3 AE+4 380 406 457 508 609 672
resistance ±20% 5 10
Independent Linear ±% 0.1 0.05%
Mechanical stroke (M.T) mm AE+9 AE+10 386 412 463 518 619 772
Resolution infinite
Size  A mm AE+135 AE+136 512 538 589 644 745 898
Size  B mm AE+187 AE+188 564 590 641 696 797 950

 

 

Note: Built-in transmitter available. Powered by 24V, it outputs 0-5V, 0-10V, 4-20mA (2-wire or 3-wire optional), and RS485.

          Built-in 0-5V, 0-10V, and 4-20mA 2-wire outputs increase the overall length by 25mm.
Built-in 4-20mA 3-wire outputs and RS485 increase the overall length by 50mm.

 

Dimension (mm)

 

1

 

Electrical parameters
Use range(mm) 50—-750
Resolution unlimited
Resistor tolerance ±20%
Normal working current of brush <1uA
Maximum current ≤10mA
Maximum operating voltage 42V
Drift per °C <1.5ppm/℃
Insulation resistance >100MOhm at 500v
Dielectric strength ≤100uA

(500VDC,50HZ)

Protection level IP60

IP67

 

Environmental parameters
Operating temperature -40…+120℃
Storage temperature -50…+120℃
Maximum movement speed ≤10m/s
Mobility ≤3.5N IP60

≤15N IP67

Vibration resistance standards 50g

11ms

Impact resistance standards 5~2000HZ

Amax=0.75mm

amax=20g

Operating temperature -50…+120℃

 

Application

 

KPC sensors are suitable for applications where there is no alignment requirement and there is oscillation, such as jacks, house crack monitoring, highway bridges, railway bridges, hydropower dams, prestressed construction projects such as high-rise buildings, sluice gates, bridge monitoring, 3D cinema seats, entertainment equipment, etc.