KPC Analog Linear Position Sensor
Products :
The KPC articulated linear displacement sensor features an articulated mounting mechanism with fixed ends. Powered by 5V or 10V, it outputs 0-5V or 0-10V. Powered by 12V/24V, it can output 0-5V, 0-10V, 4-20mA, 0-20mA, and 1-20mA. RS485 and RS232 transmitter modules are required. It is suitable for position monitoring of large mechanical travel and back-and-forth motion, with no requirements for alignment. It is suitable for applications with no alignment requirements and motion, such as robots, unloaders, brick and shoe machines, ceramic machinery, geological hazards, sluice gates, 3D cinema seats, and entertainment equipment.


To meet underground utility corridor design requirements, expansion joints are installed at regular intervals. Monitoring their width is critical to prevent issues like water seepage. Surface crack meters can be mounted directly on joints to track long-term opening and closing, even in harsh environments. Their universal joints allow limited shear displacement, while built-in temperature sensors record ambient conditions. With optional accessories, they can also function as void meters or bi-/tri-directional crack meters to measure void volume, joint displacement, or perimeter movement.
Features :
◇ Displacement range 50-750mm
◇ High resolution and immune to external signal interference
◇ Displacement speed 10m/s
◇ Output: Voltage divider ② RS485 ③ RS232
④ Voltage signal: DC24V output 0-5V/0-10V
⑤ Current signal: DC24V output 4-20mA
◇ Connector
KPC: Aviation plug with 1m shielded cable
KPC-F: Waterproof plug
◇ Service life >100 x 106 cycles under different conditions

Technical parameter
| KPC | mm | 50 | 100 | 130 | 150 | 175 | 200 | 225 | 275 | 300 | 375 | 400 | 450 | 500 | 600 | 750 |
| Actual range(A.E) | mm | 50 | 100 | 130 | 150 | 175 | 200 | 225 | 275 | 300 | 375 | 400 | 450 | 500 | 600 | 750 |
| Theoretical Range(T.E) | mm | AE+3 | AE+4 | 380 | 406 | 457 | 508 | 609 | 672 | |||||||
| resistance ±20% | kΩ | 5 | 10 | |||||||||||||
| Independent Linear | ±% | 0.1 | 0.05% | |||||||||||||
| Mechanical stroke (M.T) | mm | AE+9 | AE+10 | 386 | 412 | 463 | 518 | 619 | 772 | |||||||
| Resolution | infinite | |||||||||||||||
| Size A | mm | AE+135 | AE+136 | 512 | 538 | 589 | 644 | 745 | 898 | |||||||
| Size B | mm | AE+187 | AE+188 | 564 | 590 | 641 | 696 | 797 | 950 | |||||||
Note: Built-in transmitter available. Powered by 24V, it outputs 0-5V, 0-10V, 4-20mA (2-wire or 3-wire optional), and RS485.
Built-in 0-5V, 0-10V, and 4-20mA 2-wire outputs increase the overall length by 25mm.
Built-in 4-20mA 3-wire outputs and RS485 increase the overall length by 50mm.
Dimension (mm)

| Electrical parameters | |
| Use range(mm) | 50—-750 |
| Resolution | unlimited |
| Resistor tolerance | ±20% |
| Normal working current of brush | <1uA |
| Maximum current | ≤10mA |
| Maximum operating voltage | 42V |
| Drift per °C | <1.5ppm/℃ |
| Insulation resistance | >100MOhm at 500v |
| Dielectric strength | ≤100uA
(500VDC,50HZ) |
| Protection level | IP60
IP67 |
| Environmental parameters | |
| Operating temperature | -40…+120℃ |
| Storage temperature | -50…+120℃ |
| Maximum movement speed | ≤10m/s |
| Mobility | ≤3.5N IP60
≤15N IP67 |
| Vibration resistance standards | 50g
11ms |
| Impact resistance standards | 5~2000HZ
Amax=0.75mm amax=20g |
| Operating temperature | -50…+120℃ |
Application
KPC sensors are suitable for applications where there is no alignment requirement and there is oscillation, such as jacks, house crack monitoring, highway bridges, railway bridges, hydropower dams, prestressed construction projects such as high-rise buildings, sluice gates, bridge monitoring, 3D cinema seats, entertainment equipment, etc.