In-Line Submersible Load Cell | IP68 | Underwater Force Sensor | DDEN
O-Ring Sealed, Fully Submersible, Accurate and Easily Adaptable
Technical Specifications
| Rated Capacity (RC) | N | 0-50, 0-100, 0-250, 0-500, 0-1000, 0-2000, 0-5000, 0-10,000, 0-20,000, 0-50,000 |
|---|---|---|
| Operating Modes | Tension/Compression / Tension & Compression | |
| Sensitivity (RO) | mV/V (nominal) | 50N = 0.5 / 100N=1.0 / 250N = 0.75 / 500N = 1.5 / 1000N up = 2.0 |
| Zero Balance/Offset | ±%/Rated Output | <1.0 |
| Output Symmetry (tension vs. compression) | ±%/Rated Output | <0.25 typical |
| Non-Linearity | ±%/Rated Output (BFSL) | <0.15 (0.05 typical) |
| Hysteresis | %/Rated Output | <0.15 (0.05 typical) |
| Repeatability | ±%/Rated Output | <0.1 |
| Temperature Effect on Zero | ±%/Rated Output/ ˚C | <0.005 |
| Temperature Effect on Sensitivity | ±%/Applied Load/ ˚C | <0.005 |
| Input Resistance | Ohms | 700 |
| Output Resistance | Ohms | 700 |
| Insulation Resistance | Megohms | >5000 @ 50Vdc |
| Excitation Voltage | Volts AC or DC | 10 recommended (2-15 acceptable) – Note mV/V only, see page 5 for details of conditioned output versions. |
| Operating Temperature Range | ˚C | -20 to +80 |
| Compensated Temperature Range | ˚C | 0 to +70 |
| Storage Temperature Range | ˚C | -20 to +80 |
| Safe Overload | % of Rated Capacity | 150 |
| Ultimate Overload | % of Rated Capacity | 200 |
| Deflection @ Rated Capacity | mm | 50N=0.08; 100N=0.12; 250N=0.09; 500N=0.06; 1000N=0.04; 2000N=0.03; 5000N=0.02; 10,000N=0.015; 20,000N=0.01; 50,000N=0.03 |
| Fundamental Resonant Frequency* | kHz | 50N=1.7; 100N=1.3; 250N=0.72; 500N=1.18; 1000N=2; 2000N=3.1; 5000N=6.1; 10,000N=9.9; 20,000N=18.2; 50,000N=13.3 |
| IP Rating (Environmental Protection) | IP68 to 10m depth (please consult sales for greater depths) | |
| Weight (excluding cable) | kg | 50N to 20kN: 0.3kg / 50kN: 0.45kg, |
| Fatigue Life | 108 cycles typical (109 cycles on fatigue-rated version) | |
| Cable Length (as standard) | metres | 2 |
| Cable Type | 4-core screened submersible, PUR (weight: 82g/m) sheath, Ø7.5 | |
| Construction Materials / Wetted Parts | 17-4PH Stainless Steel, 303 Stainless Steel, PUR, NBR, TPE, Silicone | |
| Resolution | 1 part in 250,000 (with appropriate instrumentation) | |
| Pressure Effect on Output | 9N/mH²O nominal | |
| *The resonant frequency is calculated with the body of the load cell attached to a large plate, ensuring that only the sensing element oscillates: This is vital to achieve the highest natural frequency and subsequent frequency response. | ||
Product Dimensions

All dimensions are in mm
|
Model
|
Capacity
|
A
|
B
|
C
|
ØD
|
E
|
|---|---|---|---|---|---|---|
|
DDEN
|
0-50N up to 0-20kN
|
67
|
15
|
35
|
44
|
M12x1.75
|
|
DDEN
|
0-50kN
|
71
|
18
|
35
|
44
|
M16x2.0
|
|
DDENA
|
0-50N up to 0-20kN
|
67
|
15
|
35
|
44
|
M12x1.75
|
|
DDENA
|
0-50kN
|
71
|
17
|
37
|
50
|
M16x2.0
|
Wiring Details
| Wire | mV/V Output | 3-Wire Voltage or Current Otput | 4-Wire Voltage Output | 2-Wire Current | RS485 Digital |
|---|---|---|---|---|---|
| Red | +ve excitation | +ve supply | +ve supply | +ve supply | +5.4 to +18Vdc supply |
| Blue | -ve excitation | 0V common | -ve supply | -ve supply / signal | -ve supply |
| White | +ve signal (tension) * | +ve signal | +ve signal | N/C | RS485 (B) Data -ve |
| Yellow | -ve signal | N/C | -ve signal | N/C | RS485 (A) Data +ve |
| Screen | To ground – not connected to load cell body | ||||
| * +ve signal in tension is standard, +ve signal in compression can also be offered. | |||||
Ordering Codes & Options
| Core Product | Capacity (inc Engineering Units) | Cable Length (m) | Specials Code | Example Result |
|---|---|---|---|---|
| DDEN | 50N | 002 | 000 | DDEN-50N-002-000 |
| DDEN | 100N | 002 | 000 | DDEN-100N-002-000 |
| DDEN | 250N | 002 | 000 | DDEN-250N-002-000 |
| DDEN | 500N | 002 | 000 | DDEN-500N-002-000 |
| DDEN | 1000N | 002 | 000 | DDEN-1000N-002-000 |
| DDEN | 2000N | 002 | 000 | DDEN-2000N-002-000 |
| DDEN | 5000N | 002 | 000 | DDEN-5000N-002-000 |
| DDEN | 10kN | 002 | 000 | DDEN-10kN-002-000 |
| DDEN | 20kN | 002 | 000 | DDEN-20kN-002-000 |
| DDEN | 50kN | 002 | 000 | DDEN-50kN-002-000 |
Mounting And Installation Accessories
Rod End Bearings for Tension Use
Designed to align forces through the principle axis of the load cell thus reducing the effects of extraneous forces, hence offering improved performance from the cell. Rod End Bearings are used where tensile forces are being applied. Maintenance-free rod ends are a complete units made up of a housing with both an integral shank (with an internal or external thread) and a maintenance-free spherical plain bearing, located within the housing. Key Features:
- Supports radial loads in a tensile or compressive direction.
- Suitable for unilateral loads – can support alternating loads and alternating loads in combination with bearing GE..UK-2RS, consult sales.
- Stainless Steel for corrosion resistance.
- Are maintenance-free.
- Fitted with radial spherical plain bearings.
- PTFE composite sliding contact surfaces.
- Enables compact adjacent construction thanks to its thin-walled design of the eye housing.

All dimensions are in mm
| LOAD CELL | ORDERING CODES | Size (D) | B | M | A | F | L | K | J | O | SW | G | GL | Static load C0 kN | Dynamic load C kN | Limiting Speed rev/min | Weight g |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| DDEN + DDENA-50N to 20kN | GIRSW-12RR-316 | 12 | 16 | 12 | 32 | 50 | 66 | 22 | 17.5 | 15.4 | 19 | M12 | 22 | 34.5 | 32 | 300 | 115 |
| DDEN-50kN | GIRSW-16RR-316 | 16 | 21 | 15 | 42 | 64 | 85 | 27 | 22 | 19.3 | 22 | M16 | 28 | 60.5 | 52.5 | 230 | 230 |