{"id":45862,"date":"2025-07-01T10:29:30","date_gmt":"2025-07-01T01:29:30","guid":{"rendered":"https:\/\/ksensors.co.kr\/product\/daysensor-dyjn-102-torque-sensor\/"},"modified":"2025-07-01T10:29:30","modified_gmt":"2025-07-01T01:29:30","slug":"daysensor-dyjn-102-torque-sensor","status":"publish","type":"product","link":"https:\/\/ksensors.co.kr\/en\/product\/daysensor-dyjn-102-torque-sensor\/","title":{"rendered":"DAYSENSOR \/ DYJN-102 \/ Torque Sensor"},"content":{"rendered":"<h4><strong>Models<\/strong><\/h4>\n<p>DYJN-102<\/p>\n<h4><strong>Features<\/strong><\/h4>\n<ul>\n<li data-start=\"69\" data-end=\"91\">\n<p data-start=\"71\" data-end=\"91\">Dust and water resistance rating (protection rating)<\/p>\n<\/li>\n<li data-start=\"92\" data-end=\"121\">\n<p data-start=\"94\" data-end=\"121\">For use in static conditions, not continuous rotation<\/p>\n<\/li>\n<li data-start=\"122\" data-end=\"141\">\n<p data-start=\"124\" data-end=\"141\">Non-standard\/custom specifications available<\/p>\n<\/li>\n<li data-start=\"142\" data-end=\"170\">\n<p data-start=\"144\" data-end=\"170\">Excellent signal stability and strong electromagnetic interference suppression<\/p>\n<\/li>\n<li data-start=\"171\" data-end=\"184\">\n<p data-start=\"173\" data-end=\"184\">Use of high-grade alloy steel<\/p>\n<\/li>\n<li data-start=\"185\" data-end=\"262\">\n<p data-start=\"187\" data-end=\"262\">Widely applied to static torque measurement of non-rotating torque test systems (testing machines, torque wrenches, steering motor actuators, valves, transmissions, etc.)<\/p>\n<\/li>\n<\/ul>\n<h4><strong>Dimensi<\/strong><strong>ons<\/strong><\/h4>\n<p><img fetchpriority=\"high\" decoding=\"async\" class=\"alignnone size-large wp-image-14364\" src=\"http:\/\/ksensors.co.kr\/wp-content\/uploads\/2025\/07\/DYJN-102_%EB%8F%84%EB%A9%B4-520x1024.jpg\" alt=\"\" width=\"520\" height=\"1024\"><\/p>\n<h4><strong>Specifications<\/strong><\/h4>\n<div class=\"flex basis-auto flex-col -mb-(--composer-overlap-px) [--composer-overlap-px:55px] grow overflow-hidden\">\n<div class=\"relative h-full\">\n<div class=\"flex h-full flex-col overflow-y-auto [scrollbar-gutter:stable_both-edges] @[84rem]\/thread:pt-(--header-height)\">\n<div class=\"@thread-xl\/thread:pt-header-height flex flex-col text-sm pb-25\">\n<article class=\"text-token-text-primary w-full\" dir=\"auto\" data-testid=\"conversation-turn-292\" data-scroll-anchor=\"true\">\n<div class=\"text-base my-auto mx-auto py-5 [--thread-content-margin:--spacing(4)] @[37rem]:[--thread-content-margin:--spacing(6)] @[72rem]:[--thread-content-margin:--spacing(16)] px-(--thread-content-margin)\">\n<div class=\"[--thread-content-max-width:32rem] @[34rem]:[--thread-content-max-width:40rem] @[64rem]:[--thread-content-max-width:48rem] mx-auto flex max-w-(--thread-content-max-width) flex-1 text-base gap-4 md:gap-5 lg:gap-6 group\/turn-messages focus-visible:outline-hidden\" tabindex=\"-1\">\n<div class=\"group\/conversation-turn relative flex w-full min-w-0 flex-col agent-turn\">\n<div class=\"relative flex-col gap-1 md:gap-3\">\n<div class=\"flex max-w-full flex-col grow\">\n<div class=\"min-h-8 text-message relative flex w-full flex-col items-end gap-2 text-start break-words whitespace-normal [.text-message+&amp;]:mt-5\" dir=\"auto\" data-message-author-role=\"assistant\" data-message-id=\"1ca77515-c27b-462c-acd6-f72f437b9dc8\" data-message-model-slug=\"gpt-4o\">\n<div class=\"flex w-full flex-col gap-1 empty:hidden first:pt-[3px]\">\n<div class=\"markdown prose dark:prose-invert w-full break-words light\">\n<div class=\"_tableContainer_80l1q_1\">\n<div class=\"_tableWrapper_80l1q_14 group flex w-fit flex-col-reverse\" tabindex=\"-1\">\n<table class=\"w-fit min-w-(--thread-content-width)\" data-start=\"61\" data-end=\"2037\">\n<thead data-start=\"61\" data-end=\"149\">\n<tr data-start=\"61\" data-end=\"149\">\n<th data-start=\"61\" data-end=\"96\" data-col-size=\"sm\">Item<\/th>\n<th data-start=\"96\" data-end=\"111\" data-col-size=\"sm\">Unit<\/th>\n<th data-start=\"111\" data-end=\"149\" data-col-size=\"sm\">Value<\/th>\n<\/tr>\n<\/thead>\n<tbody data-start=\"240\" data-end=\"2037\">\n<tr data-start=\"240\" data-end=\"329\">\n<td data-start=\"240\" data-end=\"275\" data-col-size=\"sm\">Rated Capacity<\/td>\n<td data-col-size=\"sm\" data-start=\"275\" data-end=\"290\">N\u00b7m<\/td>\n<td data-col-size=\"sm\" data-start=\"290\" data-end=\"329\">0\u2013200<\/td>\n<\/tr>\n<tr data-start=\"330\" data-end=\"419\">\n<td data-start=\"330\" data-end=\"365\" data-col-size=\"sm\">Output Sensitivity<\/td>\n<td data-col-size=\"sm\" data-start=\"365\" data-end=\"380\">mV\/V<\/td>\n<td data-col-size=\"sm\" data-start=\"380\" data-end=\"419\">2.0 \u00b110%<\/td>\n<\/tr>\n<tr data-start=\"420\" data-end=\"509\">\n<td data-start=\"420\" data-end=\"455\" data-col-size=\"sm\">Zero Output<\/td>\n<td data-col-size=\"sm\" data-start=\"455\" data-end=\"470\">%F.S.<\/td>\n<td data-col-size=\"sm\" data-start=\"470\" data-end=\"509\">\u00b12<\/td>\n<\/tr>\n<tr data-start=\"510\" data-end=\"599\">\n<td data-start=\"510\" data-end=\"545\" data-col-size=\"sm\">Non-linearity<\/td>\n<td data-col-size=\"sm\" data-start=\"545\" data-end=\"560\">%F.S.<\/td>\n<td data-col-size=\"sm\" data-start=\"560\" data-end=\"599\">0.3<\/td>\n<\/tr>\n<tr data-start=\"600\" data-end=\"689\">\n<td data-start=\"600\" data-end=\"635\" data-col-size=\"sm\">Hysteresis<\/td>\n<td data-col-size=\"sm\" data-start=\"635\" data-end=\"650\">%F.S.<\/td>\n<td data-col-size=\"sm\" data-start=\"650\" data-end=\"689\">0.1<\/td>\n<\/tr>\n<tr data-start=\"690\" data-end=\"779\">\n<td data-start=\"690\" data-end=\"725\" data-col-size=\"sm\">Repeatability<\/td>\n<td data-col-size=\"sm\" data-start=\"725\" data-end=\"740\">%F.S.<\/td>\n<td data-col-size=\"sm\" data-start=\"740\" data-end=\"779\">0.1<\/td>\n<\/tr>\n<tr data-start=\"780\" data-end=\"869\">\n<td data-start=\"780\" data-end=\"815\" data-col-size=\"sm\">Creep (30 minutes)<\/td>\n<td data-col-size=\"sm\" data-start=\"815\" data-end=\"830\">%F.S.<\/td>\n<td data-col-size=\"sm\" data-start=\"830\" data-end=\"869\">0.1<\/td>\n<\/tr>\n<tr data-start=\"870\" data-end=\"959\">\n<td data-start=\"870\" data-end=\"905\" data-col-size=\"sm\">Temperature Effect on Sensitivity<\/td>\n<td data-col-size=\"sm\" data-start=\"905\" data-end=\"920\">%F.S.\/10\u2103<\/td>\n<td data-col-size=\"sm\" data-start=\"920\" data-end=\"959\">0.05<\/td>\n<\/tr>\n<tr data-start=\"960\" data-end=\"1049\">\n<td data-start=\"960\" data-end=\"995\" data-col-size=\"sm\">Temperature Effect on Zero<\/td>\n<td data-col-size=\"sm\" data-start=\"995\" data-end=\"1010\">%F.S.\/10\u2103<\/td>\n<td data-col-size=\"sm\" data-start=\"1010\" data-end=\"1049\">0.05<\/td>\n<\/tr>\n<tr data-start=\"1050\" data-end=\"1139\">\n<td data-start=\"1050\" data-end=\"1085\" data-col-size=\"sm\">Frequency Response<\/td>\n<td data-col-size=\"sm\" data-start=\"1085\" data-end=\"1100\">kHz<\/td>\n<td data-col-size=\"sm\" data-start=\"1100\" data-end=\"1139\">10<\/td>\n<\/tr>\n<tr data-start=\"1140\" data-end=\"1229\">\n<td data-start=\"1140\" data-end=\"1175\" data-col-size=\"sm\">Material<\/td>\n<td data-col-size=\"sm\" data-start=\"1175\" data-end=\"1190\">\u2014<\/td>\n<td data-col-size=\"sm\" data-start=\"1190\" data-end=\"1229\">Alloy Steel<\/td>\n<\/tr>\n<tr data-start=\"1230\" data-end=\"1319\">\n<td data-start=\"1230\" data-end=\"1265\" data-col-size=\"sm\">Impedance<\/td>\n<td data-col-size=\"sm\" data-start=\"1265\" data-end=\"1280\">\u03a9<\/td>\n<td data-col-size=\"sm\" data-start=\"1280\" data-end=\"1319\">350<\/td>\n<\/tr>\n<tr data-start=\"1320\" data-end=\"1409\">\n<td data-start=\"1320\" data-end=\"1355\" data-col-size=\"sm\">Insulation Resistance<\/td>\n<td data-col-size=\"sm\" data-start=\"1355\" data-end=\"1370\">M\u03a9\/100V DC<\/td>\n<td data-col-size=\"sm\" data-start=\"1370\" data-end=\"1409\">\u22655000<\/td>\n<\/tr>\n<tr data-start=\"1410\" data-end=\"1499\">\n<td data-start=\"1410\" data-end=\"1445\" data-col-size=\"sm\">Operating Voltage<\/td>\n<td data-start=\"1445\" data-end=\"1460\" data-col-size=\"sm\">V<\/td>\n<td data-start=\"1460\" data-end=\"1499\" data-col-size=\"sm\">5\u201315<\/td>\n<\/tr>\n<tr data-start=\"1500\" data-end=\"1589\">\n<td data-start=\"1500\" data-end=\"1535\" data-col-size=\"sm\">Operating Temperature Range<\/td>\n<td data-col-size=\"sm\" data-start=\"1535\" data-end=\"1550\">\u2103<\/td>\n<td data-col-size=\"sm\" data-start=\"1550\" data-end=\"1589\">-20 to +80<\/td>\n<\/tr>\n<tr data-start=\"1590\" data-end=\"1679\">\n<td data-start=\"1590\" data-end=\"1625\" data-col-size=\"sm\">Safe Overload<\/td>\n<td data-col-size=\"sm\" data-start=\"1625\" data-end=\"1640\">%R.C.<\/td>\n<td data-col-size=\"sm\" data-start=\"1640\" data-end=\"1679\">120<\/td>\n<\/tr>\n<tr data-start=\"1680\" data-end=\"1769\">\n<td data-start=\"1680\" data-end=\"1715\" data-col-size=\"sm\">Ultimate Overload<\/td>\n<td data-col-size=\"sm\" data-start=\"1715\" data-end=\"1730\">%R.C.<\/td>\n<td data-col-size=\"sm\" data-start=\"1730\" data-end=\"1769\">150<\/td>\n<\/tr>\n<tr data-start=\"1770\" data-end=\"1859\">\n<td data-start=\"1770\" data-end=\"1805\" data-col-size=\"sm\">Cable Specification<\/td>\n<td data-col-size=\"sm\" data-start=\"1805\" data-end=\"1820\">m<\/td>\n<td data-col-size=\"sm\" data-start=\"1820\" data-end=\"1859\">\u03a65 \u00d7 3m<\/td>\n<\/tr>\n<tr data-start=\"1860\" data-end=\"1949\">\n<td data-start=\"1860\" data-end=\"1895\" data-col-size=\"sm\">Cable Maximum Tension<\/td>\n<td data-col-size=\"sm\" data-start=\"1895\" data-end=\"1910\">kg<\/td>\n<td data-col-size=\"sm\" data-start=\"1910\" data-end=\"1949\">10<\/td>\n<\/tr>\n<tr data-start=\"1950\" data-end=\"2037\">\n<td data-start=\"1950\" data-end=\"1992\" data-col-size=\"sm\">TEDS (Transducer Electronic Data Sheet)<\/td>\n<td data-col-size=\"sm\" data-start=\"1992\" data-end=\"1998\">\u2014<\/td>\n<td data-col-size=\"sm\" data-start=\"1998\" data-end=\"2037\">Optional<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<div class=\"sticky end-(--thread-content-margin) h-0 self-end select-none\">\n<div class=\"absolute end-0 flex items-end\"><img decoding=\"async\" class=\"alignnone size-large wp-image-1256\" src=\"http:\/\/ksensors.co.kr\/wp-content\/uploads\/2025\/05\/KSENSORS-1024x195.jpg\" alt=\"\" width=\"600\" height=\"114\"><\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/article>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<div id=\"thread-bottom-container\" class=\"content-fade relative isolate z-10 w-full basis-auto has-data-has-thread-error:pt-2 has-data-has-thread-error:[box-shadow:var(--sharp-edge-bottom-shadow)] md:border-transparent md:pt-0 dark:border-white\/20 md:dark:border-transparent flex flex-col\">\n<div id=\"thread-bottom\">\n<div class=\"text-base mx-auto [--thread-content-margin:--spacing(4)] @[37rem]:[--thread-content-margin:--spacing(6)] @[72rem]:[--thread-content-margin:--spacing(16)] px-(--thread-content-margin)\">\n<div class=\"[--thread-content-max-width:32rem] @[34rem]:[--thread-content-max-width:40rem] @[64rem]:[--thread-content-max-width:48rem] mx-auto flex max-w-(--thread-content-max-width) flex-1 text-base gap-4 md:gap-5 lg:gap-6\">\n<div class=\"max-xs:[--force-hide-label:none] relative z-1 flex h-full max-w-full flex-1 flex-col\" role=\"button\" aria-haspopup=\"dialog\" aria-expanded=\"false\" aria-controls=\"radix-\u00abr3o\u00bb\" data-state=\"closed\">\n<form class=\"w-full [view-transition-name:var(--vt-composer)]\" role=\"region\" aria-label=\"\uba54\uc2dc\uc9c0 \ucef4\ud3ec\uc800\" data-type=\"unified-composer\">\n<div class=\"bg-token-bg-primary flex w-full cursor-text flex-col items-center justify-center overflow-clip bg-clip-padding contain-inline-size dark:bg-[#303030] shadow-short rounded-[28px]\">\n<div class=\"relative flex w-full items-end px-2.5 py-2.5\">\n<div class=\"relative flex w-full flex-auto flex-col\">\n<div><\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/form>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<p>This sensor boasts protection performance and high signal stability, making it a high-precision product suitable for torque measurement in static or non-rotating conditions. Non-standard specifications are also available for flexible application in a variety of industries and equipment. <\/p>\n","protected":false},"featured_media":15998,"template":"","meta":[],"product_brand":[395],"product_cat":[391],"product_tag":[541],"class_list":{"0":"post-45862","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_brand-daysensor-en","7":"product_cat-torque-sensor","8":"product_tag--en","10":"first","11":"instock","12":"taxable","13":"shipping-taxable","14":"product-type-simple"},"aioseo_notices":[],"_links":{"self":[{"href":"https:\/\/ksensors.co.kr\/en\/wp-json\/wp\/v2\/product\/45862","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/ksensors.co.kr\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/ksensors.co.kr\/en\/wp-json\/wp\/v2\/types\/product"}],"version-history":[{"count":0,"href":"https:\/\/ksensors.co.kr\/en\/wp-json\/wp\/v2\/product\/45862\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/ksensors.co.kr\/en\/wp-json\/wp\/v2\/media\/15998"}],"wp:attachment":[{"href":"https:\/\/ksensors.co.kr\/en\/wp-json\/wp\/v2\/media?parent=45862"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/ksensors.co.kr\/en\/wp-json\/wp\/v2\/product_brand?post=45862"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/ksensors.co.kr\/en\/wp-json\/wp\/v2\/product_cat?post=45862"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/ksensors.co.kr\/en\/wp-json\/wp\/v2\/product_tag?post=45862"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}