{"id":308261,"date":"2026-01-05T15:26:52","date_gmt":"2026-01-05T06:26:52","guid":{"rendered":"https:\/\/ksensors.co.kr\/product\/zemic-bm14a-compression-load-cell-zemic-canister-load-cell\/"},"modified":"2026-01-05T15:26:52","modified_gmt":"2026-01-05T06:26:52","slug":"zemic-bm14a-compression-load-cell-zemic-canister-load-cell","status":"publish","type":"product","link":"https:\/\/ksensors.co.kr\/en\/product\/zemic-bm14a-compression-load-cell-zemic-canister-load-cell\/","title":{"rendered":"Zemic \/ BM14A Compression Canister Load Cell"},"content":{"rendered":"<h1 class=\"this-description-name\">BM14A Compression Load Cell Zemic Canister Load Cell\u00a0<i class=\"fa fa-qrcode\" aria-hidden=\"true\"><\/i><\/h1>\n<p><strong><a>Product Description<\/a><\/strong><\/p>\n<div class=\"detial-cont-tabscont\">\n<div class=\"fix prodDesc\">\n<div class=\"prodDetail-editor-container \">\n<p><img decoding=\"async\" class=\" lazyloaded\" title=\"\u56fe\u72471\" src=\"https:\/\/ksensors.co.kr\/wp-content\/uploads\/2026\/01\/181_tupian1.png\" alt=\"\u56fe\u72471\" data-original=\"\/\/ilrorwxhklojlp5p.ldycdn.com\/cloud\/lkBpoKmlliSRojmklrmoip\/tupian1.png\" \/><\/p>\n<p><strong>Short Description:<\/strong><\/p>\n<p>\u25ceStainless steel IP68 compression load cell\uff1b<\/p>\n<p>\u25ceHermetically sealed\uff1b<\/p>\n<p>\u25ceSuitable for vehicle and hopper scales and vehicle testing facilities\uff1b<\/p>\n<p>\u25ceBuilt in surge arrestors\uff1b<\/p>\n<p>\u25ceCurrent calibrated (sc-option)\uff1b<\/p>\n<p><strong>Dimensions in mm\uff1a<\/strong><\/p>\n<p><img decoding=\"async\" class=\" lazyloaded\" title=\"\u56fe\u72472\" src=\"https:\/\/ksensors.co.kr\/wp-content\/uploads\/2026\/01\/176_tupian2.png\" alt=\"\u56fe\u72472\" data-original=\"\/\/ilrorwxhklojlp5p.ldycdn.com\/cloud\/loBpoKmlliSRojmklriqiq\/tupian2.png\" \/><\/p>\n<div class=\"sliderTable mt10 mb10 sliderTable-index0 change-to-org\">\n<div class=\"inner\">\n<table width=\"629\">\n<tbody>\n<tr class=\"firstRow\">\n<td valign=\"top\" width=\"104\">Dimension<\/p>\n<p>Capacity<\/td>\n<td valign=\"top\" width=\"56\">\u03a6A<\/td>\n<td valign=\"top\" width=\"53\">B<\/td>\n<td valign=\"top\" width=\"49\">C<\/td>\n<td valign=\"top\" width=\"56\">\u03a6D<\/td>\n<td valign=\"top\" width=\"49\">E<\/td>\n<td valign=\"top\" width=\"50\">F<\/td>\n<td valign=\"top\" width=\"51\">G<\/td>\n<td valign=\"top\" width=\"53\">\u03a6H<\/td>\n<td valign=\"top\" width=\"47\">J<\/td>\n<td valign=\"top\" width=\"62\">SR<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\" width=\"104\">10\/25t<\/td>\n<td valign=\"top\" width=\"56\">73 (2.87)<\/td>\n<td valign=\"top\" width=\"53\">82.5 (3.25)<\/td>\n<td valign=\"top\" width=\"49\">12 (0.47)<\/td>\n<td valign=\"top\" width=\"56\">58 (2.28)<\/td>\n<td valign=\"top\" width=\"49\">7 (0.28)<\/td>\n<td valign=\"top\" width=\"50\">1.8 (0.07)<\/td>\n<td valign=\"top\" width=\"51\">64 (2.52)<\/td>\n<td valign=\"top\" width=\"53\">31.8 (1.25)<\/td>\n<td valign=\"top\" width=\"47\">M12<\/td>\n<td valign=\"top\" width=\"62\">152 (5.98)<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\" width=\"104\">40\/60t<\/td>\n<td valign=\"top\" width=\"56\">105 (4.13)<\/td>\n<td valign=\"top\" width=\"53\">127 (5.0)<\/td>\n<td valign=\"top\" width=\"49\">34 (1.34)<\/td>\n<td valign=\"top\" width=\"56\">82.5 (3.25)<\/td>\n<td valign=\"top\" width=\"49\">9 (0.35)<\/td>\n<td valign=\"top\" width=\"50\">11 (0.43)<\/td>\n<td valign=\"top\" width=\"51\">87 (3.43)<\/td>\n<td valign=\"top\" width=\"53\">58.7 (2.31)<\/td>\n<td valign=\"top\" width=\"47\">M20<\/td>\n<td valign=\"top\" width=\"62\">152 (5.98)<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\" width=\"104\">100t<\/td>\n<td valign=\"top\" width=\"56\">152.4 (6.0)<\/td>\n<td valign=\"top\" width=\"53\">184 (7.24)<\/td>\n<td valign=\"top\" width=\"49\">72 (2.83)<\/td>\n<td valign=\"top\" width=\"56\">123.8 (4.87)<\/td>\n<td valign=\"top\" width=\"49\">23 (0.91)<\/td>\n<td valign=\"top\" width=\"50\">21 (0.83)<\/td>\n<td valign=\"top\" width=\"51\">108 (4.25)<\/td>\n<td valign=\"top\" width=\"53\">79.4 (3.13)<\/td>\n<td valign=\"top\" width=\"47\">M20<\/td>\n<td valign=\"top\" width=\"62\">432 (17.01)<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\" width=\"104\">200t<\/td>\n<td valign=\"top\" width=\"56\">167.6 (6.60)<\/td>\n<td valign=\"top\" width=\"53\">228.6 (9.0)<\/td>\n<td valign=\"top\" width=\"49\">92 (3.62)<\/td>\n<td valign=\"top\" width=\"56\">136.3 (5.37)<\/td>\n<td valign=\"top\" width=\"49\">10 (0.39)<\/td>\n<td valign=\"top\" width=\"50\">25 (0.98)<\/td>\n<td valign=\"top\" width=\"51\">123 (4.84)<\/td>\n<td valign=\"top\" width=\"53\">93.7 (3.69)<\/td>\n<td valign=\"top\" width=\"47\">M20<\/td>\n<td valign=\"top\" width=\"62\">432 (17.01)<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<p><strong>Available models\uff1a<\/strong><\/p>\n<div class=\"sliderTable mt10 mb10 sliderTable-index1 change-to-org\">\n<div class=\"inner\">\n<table width=\"630\">\n<tbody>\n<tr class=\"firstRow\">\n<td valign=\"center\" width=\"119\">Capacity<\/td>\n<td valign=\"center\" width=\"185\">Accuracy<\/td>\n<td valign=\"center\" width=\"326\">Full article description<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\" width=\"119\">10t<\/td>\n<td valign=\"center\" width=\"185\">C3<\/td>\n<td valign=\"center\" width=\"326\">BM14A-C3-10t-10B<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\" width=\"119\">25t<\/td>\n<td valign=\"center\" width=\"185\">C3<\/td>\n<td valign=\"center\" width=\"326\">BM14A-C3-25t-20B<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\" width=\"119\">40t<\/td>\n<td valign=\"center\" width=\"185\">C3<\/td>\n<td valign=\"center\" width=\"326\">BM14A-C3-40t-20B<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\" width=\"119\">60t<\/td>\n<td valign=\"center\" width=\"185\">C3<\/td>\n<td valign=\"center\" width=\"326\">BM14A-C3-60t-20B<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\" width=\"119\">100t<\/td>\n<td valign=\"center\" width=\"185\">C3<\/td>\n<td valign=\"center\" width=\"326\">BM14A-C3-100t-20B<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\" width=\"119\">200t<\/td>\n<td valign=\"center\" width=\"185\">G1 Excluded from OIML<\/td>\n<td valign=\"center\" width=\"326\">BM14A-G1-200t-20B<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<p><strong>Specification\uff1a<\/strong><\/p>\n<div class=\"sliderTable mt10 mb10 sliderTable-index2 change-to-org\">\n<div class=\"inner\">\n<table width=\"630\">\n<tbody>\n<tr class=\"firstRow\">\n<td valign=\"center\" width=\"317\">Accuracy class<\/td>\n<td valign=\"center\" width=\"67\"><\/td>\n<td colspan=\"2\" valign=\"center\" width=\"168\">OIML R60 C3<\/td>\n<td valign=\"center\" width=\"77\">G1<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\" width=\"317\">Output sensitivity ( = FS )<\/td>\n<td valign=\"center\" width=\"67\">mV\/V<\/td>\n<td colspan=\"3\" valign=\"center\" width=\"246\">2.0 \u00b1 0.002<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\" width=\"317\">Maximum capacity ( Emax )<\/td>\n<td valign=\"center\" width=\"67\">t<\/td>\n<td valign=\"center\" width=\"82\">10, 25, 40<\/td>\n<td valign=\"center\" width=\"86\">60, 100<\/td>\n<td valign=\"center\" width=\"77\">200<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\" width=\"317\">Maximum number of load cell intervals ( nLC )<\/td>\n<td valign=\"center\" width=\"67\"><\/td>\n<td colspan=\"3\" valign=\"center\" width=\"246\">3000<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\" width=\"317\">Ratio of minimum LC verification interval Y = Emax \/ vmin<\/td>\n<td valign=\"center\" width=\"67\"><\/td>\n<td valign=\"center\" width=\"82\">9000<\/td>\n<td valign=\"center\" width=\"86\">10000<\/td>\n<td valign=\"center\" width=\"77\"><\/td>\n<\/tr>\n<tr>\n<td valign=\"center\" width=\"317\">Combined error<\/td>\n<td valign=\"center\" width=\"67\">%FS<\/td>\n<td colspan=\"2\" valign=\"center\" width=\"168\">\u00b1 0.023<\/td>\n<td valign=\"center\" width=\"77\">\u00b1 0.100<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\" width=\"317\">Minimum dead load<\/td>\n<td valign=\"center\" width=\"67\">t<\/td>\n<td colspan=\"3\" valign=\"center\" width=\"246\">0<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\" width=\"317\">Safe overload<\/td>\n<td valign=\"center\" width=\"67\">of Emax<\/td>\n<td colspan=\"3\" valign=\"center\" width=\"246\">150 %<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\" width=\"317\">Ultimate overload<\/td>\n<td valign=\"center\" width=\"67\">of Emax<\/td>\n<td colspan=\"3\" valign=\"center\" width=\"246\">300 %<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\" width=\"317\">Zero balance<\/td>\n<td valign=\"center\" width=\"67\">%FS<\/td>\n<td colspan=\"3\" valign=\"center\" width=\"246\">\u00b1 1.0<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\" width=\"317\">Excitation, recommended voltage<\/td>\n<td valign=\"center\" width=\"67\">V<\/td>\n<td colspan=\"3\" valign=\"center\" width=\"246\">5 ~ 12( DC )<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\" width=\"317\">Excitation maximum<\/td>\n<td valign=\"center\" width=\"67\">V<\/td>\n<td colspan=\"3\" valign=\"center\" width=\"246\">18( DC )<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\" width=\"317\">Input resistance<\/td>\n<td valign=\"center\" width=\"67\">\u03a9<\/td>\n<td colspan=\"3\" valign=\"center\" width=\"246\">450 \u00b1 5<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\" width=\"317\">Output resistance<\/td>\n<td valign=\"center\" width=\"67\">\u03a9<\/td>\n<td colspan=\"3\" valign=\"center\" width=\"246\">480 \u00b1 5<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\" width=\"317\">Insulation resistance<\/td>\n<td valign=\"center\" width=\"67\">M\u03a9<\/td>\n<td colspan=\"3\" valign=\"center\" width=\"246\">\u2265 5000 ( 50VDC )<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\" width=\"317\">Compensated temperature<\/td>\n<td valign=\"center\" width=\"67\">\u2103<\/td>\n<td colspan=\"3\" valign=\"center\" width=\"246\">-10 ~+40<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\" width=\"317\">Operating temperature<\/td>\n<td valign=\"center\" width=\"67\">\u2103<\/td>\n<td colspan=\"3\" valign=\"center\" width=\"246\">-35 ~ +65<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\" width=\"317\">Storage temperature<\/td>\n<td valign=\"center\" width=\"67\">\u2103<\/td>\n<td colspan=\"3\" valign=\"center\" width=\"246\">-40 ~ +70<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\" width=\"317\">Element material<\/td>\n<td valign=\"center\" width=\"67\"><\/td>\n<td colspan=\"3\" valign=\"center\" width=\"246\">Stainless steel<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\" width=\"317\">Ingress protection (according to EN 60529)<\/td>\n<td valign=\"center\" width=\"67\"><\/td>\n<td colspan=\"3\" valign=\"center\" width=\"246\">IP68<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\" width=\"317\">ATEX classification (optional)<\/td>\n<td valign=\"center\" width=\"67\"><\/td>\n<td valign=\"center\" width=\"82\">II1G Ex ia IIC T4<\/td>\n<td valign=\"center\" width=\"86\">II1D Ex iaD 20 T73\u2103<\/td>\n<td valign=\"center\" width=\"77\">II3G Ex nL IIC T4<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<p><strong>Wiring\uff1a<\/strong><\/p>\n<p>\u25ceShielded, 4 conductor cable\uff1b<\/p>\n<p>\u25ceCable diameter: \u03a6 7.7mm\uff1b<\/p>\n<p>\u25ceStandard cable length for 10t: 10m and for all other capacities: 20m\uff1b<\/p>\n<p>\u25ceShield not connected to element\uff1b<\/p>\n<p><strong>BM14A Part:<\/strong><\/p>\n<p><img decoding=\"async\" class=\" lazyloaded\" title=\"\u56fe\u72473\" src=\"https:\/\/ksensors.co.kr\/wp-content\/uploads\/2026\/01\/48_tupian3.png\" alt=\"\u56fe\u72473\" data-original=\"\/\/ilrorwxhklojlp5p.ldycdn.com\/cloud\/lnBpoKmlliSRojmklrrqiq\/tupian3.png\" \/><\/p>\n<p><strong>Features:<\/strong><\/p>\n<p>Easy installation, good self-aligning ability\u00a0anti-reversal ability\u00a0Stainless steel construction, anti-corrosion\u00a0can be used under hazardous environments\u00a0Mainly used for platform scales, automobile testing\u00a0facilities, electronic truck scales and other\u00a0electronic weighing devices;<\/p>\n<p>lStainless steel Assembled with:BM14A<\/p>\n<p>lM8 screw hole is for anti-reversal occasion;<\/p>\n<p><img decoding=\"async\" class=\" lazyloaded\" title=\"\u56fe\u72474\" src=\"https:\/\/ksensors.co.kr\/wp-content\/uploads\/2026\/01\/12_tupian4.png\" alt=\"\u56fe\u72474\" data-original=\"\/\/ilrorwxhklojlp5p.ldycdn.com\/cloud\/lqBpoKmlliSRojmklrjqiq\/tupian4.png\" \/><\/p>\n<\/div>\n<\/div>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<p>BM14A Compression Load Cell Zemic Canister Load Cell\u00a0 Product Description Short Description: \u25ceStainless steel IP68 compression load cell\uff1b \u25ceHermetically sealed\uff1b \u25ceSuitable for vehicle and hopper scales and vehicle testing facilities\uff1b \u25ceBuilt in surge arrestors\uff1b \u25ceCurrent calibrated (sc-option)\uff1b Dimensions in mm\uff1a Dimension Capacity \u03a6A B C \u03a6D E F G \u03a6H J SR 10\/25t 73 (2.87) [&hellip;]<\/p>\n","protected":false},"featured_media":308245,"template":"","meta":[],"product_brand":[2431],"product_cat":[2340],"product_tag":[1005],"class_list":["post-308261","product","type-product","status-publish","has-post-thumbnail","product_brand-zemic-en","product_cat-compression-load-cell","product_tag---en","first","instock","taxable","shipping-taxable","product-type-simple"],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v27.4 (Yoast SEO v27.4) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>Zemic \/ BM14A Compression Canister Load Cell - KSENSORS<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/ksensors.co.kr\/en\/product\/zemic-bm14a-compression-load-cell-zemic-canister-load-cell\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Zemic \/ BM14A Compression Canister Load Cell\" \/>\n<meta property=\"og:description\" content=\"BM14A Compression Load Cell Zemic Canister Load Cell\u00a0 Product Description Short Description: \u25ceStainless steel IP68 compression load cell\uff1b \u25ceHermetically sealed\uff1b \u25ceSuitable for vehicle and hopper scales and vehicle testing facilities\uff1b \u25ceBuilt in surge arrestors\uff1b \u25ceCurrent calibrated (sc-option)\uff1b Dimensions in mm\uff1a Dimension Capacity \u03a6A B C \u03a6D E F G \u03a6H J SR 10\/25t 73 (2.87) [&hellip;]\" \/>\n<meta property=\"og:url\" content=\"https:\/\/ksensors.co.kr\/en\/product\/zemic-bm14a-compression-load-cell-zemic-canister-load-cell\/\" \/>\n<meta property=\"og:site_name\" content=\"KSENSORS\" \/>\n<meta property=\"og:image\" content=\"https:\/\/ksensors.co.kr\/wp-content\/uploads\/2026\/01\/BM14A.webp\" \/>\n\t<meta property=\"og:image:width\" content=\"751\" \/>\n\t<meta property=\"og:image:height\" content=\"750\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/webp\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data1\" content=\"1 minute\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/ksensors.co.kr\\\/en\\\/product\\\/zemic-bm14a-compression-load-cell-zemic-canister-load-cell\\\/\",\"url\":\"https:\\\/\\\/ksensors.co.kr\\\/en\\\/product\\\/zemic-bm14a-compression-load-cell-zemic-canister-load-cell\\\/\",\"name\":\"Zemic \\\/ BM14A Compression Canister Load Cell - KSENSORS\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/ksensors.co.kr\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/ksensors.co.kr\\\/en\\\/product\\\/zemic-bm14a-compression-load-cell-zemic-canister-load-cell\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/ksensors.co.kr\\\/en\\\/product\\\/zemic-bm14a-compression-load-cell-zemic-canister-load-cell\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/ksensors.co.kr\\\/wp-content\\\/uploads\\\/2026\\\/01\\\/BM14A.webp\",\"datePublished\":\"2026-01-05T06:26:52+00:00\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/ksensors.co.kr\\\/en\\\/product\\\/zemic-bm14a-compression-load-cell-zemic-canister-load-cell\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/ksensors.co.kr\\\/en\\\/product\\\/zemic-bm14a-compression-load-cell-zemic-canister-load-cell\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/ksensors.co.kr\\\/en\\\/product\\\/zemic-bm14a-compression-load-cell-zemic-canister-load-cell\\\/#primaryimage\",\"url\":\"https:\\\/\\\/ksensors.co.kr\\\/wp-content\\\/uploads\\\/2026\\\/01\\\/BM14A.webp\",\"contentUrl\":\"https:\\\/\\\/ksensors.co.kr\\\/wp-content\\\/uploads\\\/2026\\\/01\\\/BM14A.webp\",\"width\":751,\"height\":750},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/ksensors.co.kr\\\/en\\\/product\\\/zemic-bm14a-compression-load-cell-zemic-canister-load-cell\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"\ud648\",\"item\":\"https:\\\/\\\/ksensors.co.kr\\\/en\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Product Overview\",\"item\":\"https:\\\/\\\/ksensors.co.kr\\\/en\\\/product-overview\\\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"Zemic \\\/ BM14A Compression Canister Load Cell\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/ksensors.co.kr\\\/#website\",\"url\":\"https:\\\/\\\/ksensors.co.kr\\\/\",\"name\":\"KSENSORS : \ucf00\uc774\uc13c\uc11c\uc2a4\",\"description\":\"\ub85c\ub4dc\uc140, \ud1a0\ud06c\uc13c\ud130, \ubcc0\uc704\uc13c\uc11c, \uc555\ub825\uc13c\uc11c\",\"publisher\":{\"@id\":\"https:\\\/\\\/ksensors.co.kr\\\/#organization\"},\"alternateName\":\"KSENSORS\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/ksensors.co.kr\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/ksensors.co.kr\\\/#organization\",\"name\":\"\ucf00\uc774\uc13c\uc11c\uc2a4\",\"alternateName\":\"KSENSORS\",\"url\":\"https:\\\/\\\/ksensors.co.kr\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/ksensors.co.kr\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/ksensors.co.kr\\\/wp-content\\\/uploads\\\/2025\\\/05\\\/EMBLEM.png\",\"contentUrl\":\"https:\\\/\\\/ksensors.co.kr\\\/wp-content\\\/uploads\\\/2025\\\/05\\\/EMBLEM.png\",\"width\":1711,\"height\":676,\"caption\":\"\ucf00\uc774\uc13c\uc11c\uc2a4\"},\"image\":{\"@id\":\"https:\\\/\\\/ksensors.co.kr\\\/#\\\/schema\\\/logo\\\/image\\\/\"}}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"Zemic \/ BM14A Compression Canister Load Cell - KSENSORS","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/ksensors.co.kr\/en\/product\/zemic-bm14a-compression-load-cell-zemic-canister-load-cell\/","og_locale":"en_US","og_type":"article","og_title":"Zemic \/ BM14A Compression Canister Load Cell","og_description":"BM14A Compression Load Cell Zemic Canister Load Cell\u00a0 Product Description Short Description: \u25ceStainless steel IP68 compression load cell\uff1b \u25ceHermetically sealed\uff1b \u25ceSuitable for vehicle and hopper scales and vehicle testing facilities\uff1b \u25ceBuilt in surge arrestors\uff1b \u25ceCurrent calibrated (sc-option)\uff1b Dimensions in mm\uff1a Dimension Capacity \u03a6A B C \u03a6D E F G \u03a6H J SR 10\/25t 73 (2.87) [&hellip;]","og_url":"https:\/\/ksensors.co.kr\/en\/product\/zemic-bm14a-compression-load-cell-zemic-canister-load-cell\/","og_site_name":"KSENSORS","og_image":[{"width":751,"height":750,"url":"https:\/\/ksensors.co.kr\/wp-content\/uploads\/2026\/01\/BM14A.webp","type":"image\/webp"}],"twitter_card":"summary_large_image","twitter_misc":{"Est. reading time":"1 minute"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/ksensors.co.kr\/en\/product\/zemic-bm14a-compression-load-cell-zemic-canister-load-cell\/","url":"https:\/\/ksensors.co.kr\/en\/product\/zemic-bm14a-compression-load-cell-zemic-canister-load-cell\/","name":"Zemic \/ BM14A Compression Canister Load Cell - KSENSORS","isPartOf":{"@id":"https:\/\/ksensors.co.kr\/#website"},"primaryImageOfPage":{"@id":"https:\/\/ksensors.co.kr\/en\/product\/zemic-bm14a-compression-load-cell-zemic-canister-load-cell\/#primaryimage"},"image":{"@id":"https:\/\/ksensors.co.kr\/en\/product\/zemic-bm14a-compression-load-cell-zemic-canister-load-cell\/#primaryimage"},"thumbnailUrl":"https:\/\/ksensors.co.kr\/wp-content\/uploads\/2026\/01\/BM14A.webp","datePublished":"2026-01-05T06:26:52+00:00","breadcrumb":{"@id":"https:\/\/ksensors.co.kr\/en\/product\/zemic-bm14a-compression-load-cell-zemic-canister-load-cell\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/ksensors.co.kr\/en\/product\/zemic-bm14a-compression-load-cell-zemic-canister-load-cell\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/ksensors.co.kr\/en\/product\/zemic-bm14a-compression-load-cell-zemic-canister-load-cell\/#primaryimage","url":"https:\/\/ksensors.co.kr\/wp-content\/uploads\/2026\/01\/BM14A.webp","contentUrl":"https:\/\/ksensors.co.kr\/wp-content\/uploads\/2026\/01\/BM14A.webp","width":751,"height":750},{"@type":"BreadcrumbList","@id":"https:\/\/ksensors.co.kr\/en\/product\/zemic-bm14a-compression-load-cell-zemic-canister-load-cell\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"\ud648","item":"https:\/\/ksensors.co.kr\/en\/"},{"@type":"ListItem","position":2,"name":"Product Overview","item":"https:\/\/ksensors.co.kr\/en\/product-overview\/"},{"@type":"ListItem","position":3,"name":"Zemic \/ BM14A Compression Canister Load Cell"}]},{"@type":"WebSite","@id":"https:\/\/ksensors.co.kr\/#website","url":"https:\/\/ksensors.co.kr\/","name":"KSENSORS : \ucf00\uc774\uc13c\uc11c\uc2a4","description":"\ub85c\ub4dc\uc140, \ud1a0\ud06c\uc13c\ud130, \ubcc0\uc704\uc13c\uc11c, \uc555\ub825\uc13c\uc11c","publisher":{"@id":"https:\/\/ksensors.co.kr\/#organization"},"alternateName":"KSENSORS","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/ksensors.co.kr\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/ksensors.co.kr\/#organization","name":"\ucf00\uc774\uc13c\uc11c\uc2a4","alternateName":"KSENSORS","url":"https:\/\/ksensors.co.kr\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/ksensors.co.kr\/#\/schema\/logo\/image\/","url":"https:\/\/ksensors.co.kr\/wp-content\/uploads\/2025\/05\/EMBLEM.png","contentUrl":"https:\/\/ksensors.co.kr\/wp-content\/uploads\/2025\/05\/EMBLEM.png","width":1711,"height":676,"caption":"\ucf00\uc774\uc13c\uc11c\uc2a4"},"image":{"@id":"https:\/\/ksensors.co.kr\/#\/schema\/logo\/image\/"}}]}},"_links":{"self":[{"href":"https:\/\/ksensors.co.kr\/en\/wp-json\/wp\/v2\/product\/308261","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/ksensors.co.kr\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/ksensors.co.kr\/en\/wp-json\/wp\/v2\/types\/product"}],"version-history":[{"count":0,"href":"https:\/\/ksensors.co.kr\/en\/wp-json\/wp\/v2\/product\/308261\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/ksensors.co.kr\/en\/wp-json\/wp\/v2\/media\/308245"}],"wp:attachment":[{"href":"https:\/\/ksensors.co.kr\/en\/wp-json\/wp\/v2\/media?parent=308261"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/ksensors.co.kr\/en\/wp-json\/wp\/v2\/product_brand?post=308261"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/ksensors.co.kr\/en\/wp-json\/wp\/v2\/product_cat?post=308261"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/ksensors.co.kr\/en\/wp-json\/wp\/v2\/product_tag?post=308261"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}