{"id":308167,"date":"2026-01-05T15:11:33","date_gmt":"2026-01-05T06:11:33","guid":{"rendered":"https:\/\/ksensors.co.kr\/product\/zemic-hm14c-column-type-load-cell-zemic-column-shear-beam-load-cell\/"},"modified":"2026-01-05T15:11:33","modified_gmt":"2026-01-05T06:11:33","slug":"zemic-hm14c-column-type-load-cell-zemic-column-shear-beam-load-cell","status":"publish","type":"product","link":"https:\/\/ksensors.co.kr\/en\/product\/zemic-hm14c-column-type-load-cell-zemic-column-shear-beam-load-cell\/","title":{"rendered":"Zemic \/ HM14C Column Type Load Cell Zemic Column Shear Beam Load Cell"},"content":{"rendered":"<h1 class=\"this-description-name\">HM14C Column Type Load Cell Zemic Column Shear Beam Load Cell<\/h1>\n<p><strong><a>Product Description<\/a><\/strong><\/p>\n<div class=\"detial-cont-tabscont\">\n<div class=\"fix prodDesc\">\n<div class=\"prodDetail-editor-container \">\n<p><img decoding=\"async\" class=\" lazyloaded\" title=\"\u56fe\u72471\" src=\"https:\/\/ksensors.co.kr\/wp-content\/uploads\/2026\/01\/175_tupian1.png\" alt=\"\u56fe\u72471\" data-original=\"\/\/ilrorwxhklojlp5p.ldycdn.com\/cloud\/lkBpoKmlliSRojmkprpkip\/tupian1.png\" \/><\/p>\n<p><strong>Short Description:<\/strong><\/p>\n<p>\u25ceNickel plated alloy steel IP68 column shear load cell\uff1b<\/p>\n<p>\u25ceHermetically sealed\uff1b<\/p>\n<p>\u25ceSuitable for truck, track, hopper and other electronic weighing devices\uff1b<\/p>\n<p>\u25ceHigh accuracy\uff1b<\/p>\n<p>\u25ceProtected against lightning surges\uff1b<\/p>\n<p>\u25ceCurrent calibrated (sc option)\uff1b<\/p>\n<p><strong>Available models\uff1a<\/strong><\/p>\n<div class=\"sliderTable mt10 mb10 sliderTable-index0 change-to-org\">\n<div class=\"inner\">\n<table width=\"630\">\n<tbody>\n<tr class=\"firstRow\">\n<td valign=\"center\" width=\"158\">Capacity<\/td>\n<td valign=\"center\" width=\"195\">Accuracy<\/td>\n<td valign=\"center\" width=\"278\">Full\u00a0article description<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\" width=\"158\">10t<\/td>\n<td valign=\"center\" width=\"195\">C3<\/td>\n<td valign=\"center\" width=\"278\">HM14C-C3-10t-13B6<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\" width=\"158\">20t<\/td>\n<td valign=\"center\" width=\"195\">C3<\/td>\n<td valign=\"center\" width=\"278\">HM14C-C3-20t-13B6<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\" width=\"158\">25t<\/td>\n<td valign=\"center\" width=\"195\">C3<\/td>\n<td valign=\"center\" width=\"278\">HM14C-C3-25t-13B6<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\" width=\"158\">30t<\/td>\n<td valign=\"center\" width=\"195\">C3<\/td>\n<td valign=\"center\" width=\"278\">HM14C-C3-30t-13B6<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\" width=\"158\">50t<\/td>\n<td valign=\"center\" width=\"195\">C3<\/td>\n<td valign=\"center\" width=\"278\">HM14C-C3-50t-13B6<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<p><strong>Specification\uff1a<\/strong><\/p>\n<div class=\"sliderTable mt10 mb10 sliderTable-index1 change-to-org\">\n<div class=\"inner\">\n<table width=\"632\">\n<tbody>\n<tr class=\"firstRow\">\n<td valign=\"center\" width=\"284\">Accuracy class<\/td>\n<td valign=\"center\" width=\"64\"><\/td>\n<td colspan=\"3\" valign=\"center\" width=\"283\">C3<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\" width=\"284\">Output sensitivity ( = FS )<\/td>\n<td valign=\"center\" width=\"64\">mV\/V<\/td>\n<td colspan=\"3\" valign=\"center\" width=\"283\">1.5 \u00b1 0.004<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\" width=\"284\">Maximum capacity ( Emax )<\/td>\n<td valign=\"center\" width=\"64\">t<\/td>\n<td colspan=\"3\" valign=\"center\" width=\"283\">10, 20, 25, 30, 50<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\" width=\"284\">Maximum number of load cell intervals ( nLC )<\/td>\n<td valign=\"center\" width=\"64\"><\/td>\n<td colspan=\"3\" valign=\"center\" width=\"283\">3000<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" valign=\"center\" width=\"349\">Ratio of minimum LC verification interval Y = Emax \/ vmin<\/td>\n<td colspan=\"3\" valign=\"center\" width=\"283\">7500<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\" width=\"284\">Combined error<\/td>\n<td valign=\"center\" width=\"64\">%FS<\/td>\n<td colspan=\"3\" valign=\"center\" width=\"283\">\u00b1 0.023<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\" width=\"284\">Minimum dead load<\/td>\n<td valign=\"center\" width=\"64\">t<\/td>\n<td colspan=\"3\" valign=\"center\" width=\"283\">0<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\" width=\"284\">Safe overload<\/td>\n<td valign=\"center\" width=\"64\">of Emax<\/td>\n<td colspan=\"3\" valign=\"center\" width=\"283\">150 %<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\" width=\"284\">Ultimate overload<\/td>\n<td valign=\"center\" width=\"64\">of Emax<\/td>\n<td colspan=\"3\" valign=\"center\" width=\"283\">300 %<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\" width=\"284\">Zero balance<\/td>\n<td valign=\"center\" width=\"64\">%FS<\/td>\n<td colspan=\"3\" valign=\"center\" width=\"283\">\u00b1 1.0<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\" width=\"284\">Excitation, recommended voltage<\/td>\n<td valign=\"center\" width=\"64\">V<\/td>\n<td colspan=\"3\" valign=\"center\" width=\"283\">5 ~ 12( DC )<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\" width=\"284\">Excitation maximum<\/td>\n<td valign=\"center\" width=\"64\">V<\/td>\n<td colspan=\"3\" valign=\"center\" width=\"283\">18( DC )<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\" width=\"284\">Input resistance<\/td>\n<td valign=\"center\" width=\"64\">\u03a9<\/td>\n<td colspan=\"3\" valign=\"center\" width=\"283\">700 \u00b1 7<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\" width=\"284\">Output resistance<\/td>\n<td valign=\"center\" width=\"64\">\u03a9<\/td>\n<td colspan=\"3\" valign=\"center\" width=\"283\">703 \u00b1 4<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\" width=\"284\">Insulation resistance<\/td>\n<td valign=\"center\" width=\"64\">M\u03a9<\/td>\n<td colspan=\"3\" valign=\"center\" width=\"283\">\u2265 5000 ( 50VDC )<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\" width=\"284\">Compensated temperature<\/td>\n<td valign=\"center\" width=\"64\">\u2103<\/td>\n<td colspan=\"3\" valign=\"center\" width=\"283\">-10 ~+40<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\" width=\"284\">Operating temperature<\/td>\n<td valign=\"center\" width=\"64\">\u2103<\/td>\n<td colspan=\"3\" valign=\"center\" width=\"283\">-35 ~ +65<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\" width=\"284\">Storage temperature<\/td>\n<td valign=\"center\" width=\"64\">\u2103<\/td>\n<td colspan=\"3\" valign=\"center\" width=\"283\">-40 ~ +70<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\" width=\"284\">Element material<\/td>\n<td valign=\"center\" width=\"64\"><\/td>\n<td colspan=\"3\" valign=\"center\" width=\"283\">Nickel plated alloy steel<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\" width=\"284\">Ingress protection (according to EN 60529)<\/td>\n<td valign=\"center\" width=\"64\"><\/td>\n<td colspan=\"3\" valign=\"center\" width=\"283\">IP68<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\" width=\"284\">ATEX classification (optional)<\/td>\n<td valign=\"center\" width=\"64\"><\/td>\n<td valign=\"center\" width=\"78\">II1G Ex ia IIC T4<\/td>\n<td valign=\"center\" width=\"111\">II1D Ex iaD 20 T73\u2103<\/td>\n<td valign=\"center\" width=\"94\">II3G Ex nL IIC T4<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<p><strong>Dimensions in mm\uff1a<\/strong><\/p>\n<p><img decoding=\"async\" class=\" lazyloaded\" title=\"\u56fe\u72472\" src=\"https:\/\/ksensors.co.kr\/wp-content\/uploads\/2026\/01\/170_tupian2.png\" alt=\"\u56fe\u72472\" data-original=\"\/\/ilrorwxhklojlp5p.ldycdn.com\/cloud\/ljBpoKmlliSRojmkprqkip\/tupian2.png\" \/><\/p>\n<p><strong>Wiring\uff1a<\/strong><\/p>\n<p>\u25ceShielded, 6 conductor cable\uff1b<\/p>\n<p>\u25ceCable diameter: \u03a66.3mm\uff1b<\/p>\n<p>\u25ceStandard cable length: 13m\uff1b<\/p>\n<p>\u25ceShield not connected to element\uff1b<\/p>\n<\/div>\n<\/div>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<p>HM14C Column Type Load Cell Zemic Column Shear Beam Load Cell Product Description Short Description: \u25ceNickel plated alloy steel IP68 column shear load cell\uff1b \u25ceHermetically sealed\uff1b \u25ceSuitable for truck, track, hopper and other electronic weighing devices\uff1b \u25ceHigh accuracy\uff1b \u25ceProtected against lightning surges\uff1b \u25ceCurrent calibrated (sc option)\uff1b Available models\uff1a Capacity Accuracy Full\u00a0article description 10t C3 HM14C-C3-10t-13B6 [&hellip;]<\/p>\n","protected":false},"featured_media":308158,"template":"","meta":[],"product_brand":[2431],"product_cat":[2340,574],"product_tag":[575],"class_list":{"0":"post-308167","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_brand-zemic-en","7":"product_cat-compression-load-cell","8":"product_cat-column-load-cell-en","9":"product_tag---en","11":"first","12":"instock","13":"taxable","14":"shipping-taxable","15":"product-type-simple"},"aioseo_notices":[],"_links":{"self":[{"href":"https:\/\/ksensors.co.kr\/en\/wp-json\/wp\/v2\/product\/308167","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/ksensors.co.kr\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/ksensors.co.kr\/en\/wp-json\/wp\/v2\/types\/product"}],"version-history":[{"count":0,"href":"https:\/\/ksensors.co.kr\/en\/wp-json\/wp\/v2\/product\/308167\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/ksensors.co.kr\/en\/wp-json\/wp\/v2\/media\/308158"}],"wp:attachment":[{"href":"https:\/\/ksensors.co.kr\/en\/wp-json\/wp\/v2\/media?parent=308167"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/ksensors.co.kr\/en\/wp-json\/wp\/v2\/product_brand?post=308167"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/ksensors.co.kr\/en\/wp-json\/wp\/v2\/product_cat?post=308167"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/ksensors.co.kr\/en\/wp-json\/wp\/v2\/product_tag?post=308167"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}