{"id":308141,"date":"2026-01-05T15:06:26","date_gmt":"2026-01-05T06:06:26","guid":{"rendered":"https:\/\/ksensors.co.kr\/product\/zemic-bm24l3-load-cell-zemic-compression-load-cell\/"},"modified":"2026-01-05T15:06:26","modified_gmt":"2026-01-05T06:06:26","slug":"zemic-bm24l3-load-cell-zemic-compression-load-cell","status":"publish","type":"product","link":"https:\/\/ksensors.co.kr\/en\/product\/zemic-bm24l3-load-cell-zemic-compression-load-cell\/","title":{"rendered":"Zemic \/ BM24L3 Load Cell Zemic Compression Load Cell"},"content":{"rendered":"<h1 class=\"this-description-name\">BM24L3 Load Cell Zemic Compression Load Cell<\/h1>\n<p><strong><a>Product Description<\/a><\/strong><\/p>\n<div class=\"detial-cont-tabscont\">\n<div class=\"fix prodDesc\">\n<div class=\"prodDetail-editor-container \">\n<p><img decoding=\"async\" class=\" lazyloaded\" title=\"\u56fe\u72471\" src=\"https:\/\/ksensors.co.kr\/wp-content\/uploads\/2026\/01\/173_tupian1.png\" alt=\"\u56fe\u72471\" data-original=\"\/\/ilrorwxhklojlp5p.ldycdn.com\/cloud\/lnBpoKmlliSRojmknnjmip\/tupian1.png\" \/><\/p>\n<p><strong>Short Description:<\/strong><\/p>\n<p>\u25ceStainless steel, hermetically welded and high accuracy\uff1b<\/p>\n<p>\u25ceIngress protection (according to EN 60529): IP68\uff1b<\/p>\n<p>\u25ceSuitable for wheel-axle recognition and other compression force measuring devices\uff1b<\/p>\n<p><strong>Dimensions in mm\uff1a<\/strong><\/p>\n<p><img decoding=\"async\" class=\" lazyloaded\" title=\"\u56fe\u72472\" src=\"https:\/\/ksensors.co.kr\/wp-content\/uploads\/2026\/01\/168_tupian2.png\" alt=\"\u56fe\u72472\" data-original=\"\/\/ilrorwxhklojlp5p.ldycdn.com\/cloud\/loBpoKmlliSRojmknnkmip\/tupian2.png\" \/><img decoding=\"async\" class=\" lazyloaded\" title=\"\u56fe\u72473\" src=\"https:\/\/ksensors.co.kr\/wp-content\/uploads\/2026\/01\/46_tupian3.png\" alt=\"\u56fe\u72473\" data-original=\"\/\/ilrorwxhklojlp5p.ldycdn.com\/cloud\/lqBpoKmlliSRojmknnlmip\/tupian3.png\" \/><\/p>\n<p><strong>Available models\uff1a<\/strong><\/p>\n<div class=\"sliderTable mt10 mb10 sliderTable-index0 change-to-org\">\n<div class=\"inner\">\n<table width=\"617\">\n<tbody>\n<tr class=\"firstRow\">\n<td valign=\"center\" width=\"155\">Capacity<\/td>\n<td valign=\"center\" width=\"192\">Accuracy<\/td>\n<td valign=\"center\" width=\"270\">Full article description<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\" width=\"155\">2t<\/td>\n<td valign=\"center\" width=\"192\">G5<\/td>\n<td valign=\"center\" width=\"270\">BM24L3-G5-2t-6J<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<p><strong>Specification\uff1a<\/strong><\/p>\n<div class=\"sliderTable mt10 mb10 sliderTable-index1 change-to-org\">\n<div class=\"inner\">\n<table width=\"628\">\n<tbody>\n<tr class=\"firstRow\">\n<td valign=\"center\" width=\"325\">Output sensitivity ( = FS )<\/td>\n<td valign=\"center\" width=\"93\">mV\/V<\/td>\n<td valign=\"center\" width=\"210\">2.0 \u00b1 0.01<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\" width=\"325\">Combined error<\/td>\n<td valign=\"center\" width=\"93\">%FS<\/td>\n<td valign=\"center\" width=\"210\">0.50%<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\" width=\"325\">Minimum dead load<\/td>\n<td valign=\"center\" width=\"93\">of Emax<\/td>\n<td valign=\"center\" width=\"210\">\u00b10.0174<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\" width=\"325\">Safe overload<\/td>\n<td valign=\"center\" width=\"93\">of Emax<\/td>\n<td valign=\"center\" width=\"210\">150 %<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\" width=\"325\">Ultimate overload<\/td>\n<td valign=\"center\" width=\"93\">of Emax<\/td>\n<td valign=\"center\" width=\"210\">300 %<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\" width=\"325\">Zero balance<\/td>\n<td valign=\"center\" width=\"93\">%FS<\/td>\n<td valign=\"center\" width=\"210\">\u00b11.0<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\" width=\"325\">Excitation, recommended voltage<\/td>\n<td valign=\"center\" width=\"93\">V<\/td>\n<td valign=\"center\" width=\"210\">10(DC)<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\" width=\"325\">Excitation maximum<\/td>\n<td valign=\"center\" width=\"93\">V<\/td>\n<td valign=\"center\" width=\"210\">15(DC)<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\" width=\"325\">Input resistance<\/td>\n<td valign=\"center\" width=\"93\">\u03a9<\/td>\n<td valign=\"center\" width=\"210\">700\u00b17<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\" width=\"325\">Output resistance<\/td>\n<td valign=\"center\" width=\"93\">\u03a9<\/td>\n<td valign=\"center\" width=\"210\">700\u00b15<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\" width=\"325\">Insulation resistance<\/td>\n<td valign=\"center\" width=\"93\">M\u03a9<\/td>\n<td valign=\"center\" width=\"210\">\u2265 5000 ( 50VDC )<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\" width=\"325\">Compensated temperature<\/td>\n<td valign=\"center\" width=\"93\">\u2103<\/td>\n<td valign=\"center\" width=\"210\">-10 ~+40<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\" width=\"325\">Operating temperature<\/td>\n<td valign=\"center\" width=\"93\">\u2103<\/td>\n<td valign=\"center\" width=\"210\">-35 ~+65<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\" width=\"325\">Element material<\/td>\n<td valign=\"center\" width=\"93\"><\/td>\n<td valign=\"center\" width=\"210\">Stainless steel<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\" width=\"325\">Ingress protection (according to EN 60529)<\/td>\n<td valign=\"center\" width=\"93\"><\/td>\n<td valign=\"center\" width=\"210\">IP68<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\" width=\"325\">Recommended torque on fixation<\/td>\n<td valign=\"center\" width=\"93\">N.m<\/td>\n<td valign=\"center\" width=\"210\">M4:40<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<div class=\"detial-cont-tabscont\">\n<div class=\"fix prodDesc\">\n<div class=\"prodDetail-editor-container \">\n<div class=\"sliderTable mt10 mb10 sliderTable-index3 change-to-org\"><\/div>\n<\/div>\n<\/div>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<p>BM24L3 Load Cell Zemic Compression Load Cell Product Description Short Description: \u25ceStainless steel, hermetically welded and high accuracy\uff1b \u25ceIngress protection (according to EN 60529): IP68\uff1b \u25ceSuitable for wheel-axle recognition and other compression force measuring devices\uff1b Dimensions in mm\uff1a Available models\uff1a Capacity Accuracy Full article description 2t G5 BM24L3-G5-2t-6J Specification\uff1a Output sensitivity ( = FS ) [&hellip;]<\/p>\n","protected":false},"featured_media":308129,"template":"","meta":[],"product_brand":[2431],"product_cat":[2340,349],"product_tag":[1005],"class_list":{"0":"post-308141","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_brand-zemic-en","7":"product_cat-compression-load-cell","8":"product_cat-beam-en","9":"product_tag---en","11":"first","12":"instock","13":"taxable","14":"shipping-taxable","15":"product-type-simple"},"aioseo_notices":[],"_links":{"self":[{"href":"https:\/\/ksensors.co.kr\/en\/wp-json\/wp\/v2\/product\/308141","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/ksensors.co.kr\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/ksensors.co.kr\/en\/wp-json\/wp\/v2\/types\/product"}],"version-history":[{"count":0,"href":"https:\/\/ksensors.co.kr\/en\/wp-json\/wp\/v2\/product\/308141\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/ksensors.co.kr\/en\/wp-json\/wp\/v2\/media\/308129"}],"wp:attachment":[{"href":"https:\/\/ksensors.co.kr\/en\/wp-json\/wp\/v2\/media?parent=308141"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/ksensors.co.kr\/en\/wp-json\/wp\/v2\/product_brand?post=308141"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/ksensors.co.kr\/en\/wp-json\/wp\/v2\/product_cat?post=308141"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/ksensors.co.kr\/en\/wp-json\/wp\/v2\/product_tag?post=308141"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}